These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

187 related articles for article (PubMed ID: 35796882)

  • 1. CGM in the Hospital: Is It Ready for Prime Time?
    Buschur EO; Faulds E; Dungan K
    Curr Diab Rep; 2022 Sep; 22(9):451-460. PubMed ID: 35796882
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Continuous glucose monitoring in the hospital: an update in the era of COVID-19.
    Gothong C; Singh LG; Satyarengga M; Spanakis EK
    Curr Opin Endocrinol Diabetes Obes; 2022 Feb; 29(1):1-9. PubMed ID: 34845159
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Continuous Glucose Monitoring in Critically Ill Patients With COVID-19: Results of an Emergent Pilot Study.
    Sadhu AR; Serrano IA; Xu J; Nisar T; Lucier J; Pandya AR; Patham B
    J Diabetes Sci Technol; 2020 Nov; 14(6):1065-1073. PubMed ID: 33063556
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Facilitators and Barriers to Nursing Implementation of Continuous Glucose Monitoring (CGM) in Critically Ill Patients With COVID-19.
    Faulds ER; Jones L; McNett M; Smetana KS; May CC; Sumner L; Buschur E; Exline M; Ringel MD; Dungan K
    Endocr Pract; 2021 Apr; 27(4):354-361. PubMed ID: 33515756
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Implementation of Continuous Glucose Monitoring in the Hospital: Emergent Considerations for Remote Glucose Monitoring During the COVID-19 Pandemic.
    Galindo RJ; Aleppo G; Klonoff DC; Spanakis EK; Agarwal S; Vellanki P; Olson DE; Umpierrez GE; Davis GM; Pasquel FJ
    J Diabetes Sci Technol; 2020 Jul; 14(4):822-832. PubMed ID: 32536205
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Accuracy and Glycemic Efficacy of Continuous Glucose Monitors in Critically Ill COVID-19 Patients: A Retrospective Study.
    Boeder S; Kobayashi E; Ramesh G; Serences B; Kulasa K; Majithia AR
    J Diabetes Sci Technol; 2023 May; 17(3):642-648. PubMed ID: 35876258
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Use of Continuous Glucose Monitor in Critically Ill COVID-19 Patients Requiring Insulin Infusion: An Observational Study.
    Faulds ER; Boutsicaris A; Sumner L; Jones L; McNett M; Smetana KS; May CC; Buschur E; Exline MC; Ringel MD; Dungan K
    J Clin Endocrinol Metab; 2021 Sep; 106(10):e4007-e4016. PubMed ID: 34100545
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Use and Accuracy of Inpatient CGM During the COVID-19 Pandemic: An Observational Study of General Medicine and ICU Patients.
    Longo RR; Elias H; Khan M; Seley JJ
    J Diabetes Sci Technol; 2022 Sep; 16(5):1136-1143. PubMed ID: 33971753
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Real-Time Continuous Glucose Monitoring in the Hospital: A Real-World Experience.
    Spierling Bagsic SR; Fortmann AL; Belasco R; Bastian A; Lohnes S; Ritko A; Sandoval H; Chichmarenko M; Soriano EC; Talavera L; Philis-Tsimikas A
    J Diabetes Sci Technol; 2023 May; 17(3):656-666. PubMed ID: 37056168
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Insulin treatment guided by subcutaneous continuous glucose monitoring compared to frequent point-of-care measurement in critically ill patients: a randomized controlled trial.
    Boom DT; Sechterberger MK; Rijkenberg S; Kreder S; Bosman RJ; Wester JP; van Stijn I; DeVries JH; van der Voort PH
    Crit Care; 2014 Aug; 18(4):453. PubMed ID: 25139609
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Inpatient Continuous Glucose Monitoring and Glycemic Outcomes.
    Levitt DL; Silver KD; Spanakis EK
    J Diabetes Sci Technol; 2017 Sep; 11(5):1028-1035. PubMed ID: 28290224
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Nursing Perspectives on the Use of Continuous Glucose Monitoring in the Intensive Care Unit.
    Faulds ER; Dungan KM; McNett M; Jones L; Poindexter N; Exline M; Pattison J; Pasquel FJ
    J Diabetes Sci Technol; 2023 May; 17(3):649-655. PubMed ID: 37081831
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Use of a Continuous Glucose Monitoring System in High-Risk Hospitalized Noncritically Ill Patients With Diabetes After Cardiac Surgery and During Their Transition of Care From the Intensive Care Unit During COVID-19: A Pilot Study.
    Sweeney AT; Pena S; Sandeep J; Hernandez B; Chen Y; Breeze JL; Bulut A; Feghali K; Abdelrehim M; Abdelazeem M; Srivoleti P; Salvucci L; Cann SB; Norman C
    Endocr Pract; 2022 Jun; 28(6):615-621. PubMed ID: 35276324
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Continuous Glucose Monitoring for Patients with COVID-19 Pneumonia: Initial Experience at a Tertiary Care Center.
    Dumitrascu AG; Perry MF; Boone RJ; Guzman MP; Chirila RM; McNally AW; Colibaseanu DT; Meek SE; Ball CT; White LJ; Chindris AM
    Endocr Pract; 2023 Mar; 29(3):155-161. PubMed ID: 36566985
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Use of Continuous Glucose Monitoring to Assess Parenteral Nutrition-Induced Hyperglycemia in an Adult Patient With Severe COVID-19.
    Chow KW; Kelly DJ; Gupta R; Miller JD
    JPEN J Parenter Enteral Nutr; 2021 Jan; 45(1):208-211. PubMed ID: 33085780
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Complexity of continuous glucose monitoring data in critically ill patients: continuous glucose monitoring devices, sensor locations, and detrended fluctuation analysis methods.
    Signal M; Thomas F; Shaw GM; Chase JG
    J Diabetes Sci Technol; 2013 Nov; 7(6):1492-506. PubMed ID: 24351175
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Continuous glucose monitors prove highly accurate in critically ill children.
    Bridges BC; Preissig CM; Maher KO; Rigby MR
    Crit Care; 2010; 14(5):R176. PubMed ID: 20925914
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Continuous Glucose Monitoring: A Review of Recent Studies Demonstrating Improved Glycemic Outcomes.
    Rodbard D
    Diabetes Technol Ther; 2017 Jun; 19(S3):S25-S37. PubMed ID: 28585879
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Remote continuous glucose monitoring during the COVID-19 pandemic in quarantined hospitalized patients in Denmark: A structured summary of a study protocol for a randomized controlled trial.
    Klarskov CK; Lindegaard B; Pedersen-Bjergaard U; Kristensen PL
    Trials; 2020 Nov; 21(1):968. PubMed ID: 33239100
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Advancing the Use of CGM Devices in a Non-ICU Setting.
    Wang M; Singh LG; Spanakis EK
    J Diabetes Sci Technol; 2019 Jul; 13(4):674-681. PubMed ID: 30636449
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.