  • 1. Feasibility testing of a novel prosthetic socket sensor system.
    Rich TL; Voss G; Fairhurst S; Matsumoto M; Brielmaier S; Koester K; Netoff TI; Hansen AH; Ferguson JE
    Disabil Rehabil; 2023 Jul; 45(14):2374-2381. PubMed ID: 35797711
    [TBL] [Abstract][Full Text] [Related]  

  • 2. An adaptive prosthetic socket for people with transtibial amputation.
    Sanders JE; Vamos AC; Mertens JC; Allyn KJ; Larsen BG; Ballesteros D; Wang H; DeGrasse NS; Garbini JL; Hafner BJ; Friedly JL
    Sci Rep; 2024 May; 14(1):11168. PubMed ID: 38750086
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Validation of a Custom Interface Pressure Measurement System to Improve Fitting of Transtibial Prosthetic Check Sockets.
    Armitage L; Cho K; Sariyildiz E; Buller A; O'Brien S; Kark L
    Sensors (Basel); 2023 Apr; 23(7):. PubMed ID: 37050838
    [TBL] [Abstract][Full Text] [Related]  

  • 4. An Inductive Sensing System to Measure In-Socket Residual Limb Displacements for People Using Lower-Limb Prostheses.
    Henrikson KM; Weathersby EJ; Larsen BG; Cagle JC; McLean JB; Sanders JE
    Sensors (Basel); 2018 Nov; 18(11):. PubMed ID: 30423932
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Northwestern University Flexible Subischial Vacuum Socket for persons with transfemoral amputation: Part 2 Description and Preliminary evaluation.
    Fatone S; Caldwell R
    Prosthet Orthot Int; 2017 Jun; 41(3):246-250. PubMed ID: 28132589
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Development and acceptability testing of decision trees for self-management of prosthetic socket fit in adults with lower limb amputation.
    Lee DJ; Veneri DA
    Disabil Rehabil; 2018 May; 40(9):1066-1071. PubMed ID: 28637137
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Automatic Control of Prosthetic Socket Size for People WithTranstibial Amputation: Implementation and Evaluation.
    Weathersby EJ; Garbini JL; Larsen BG; McLean JB; Vamos AC; Sanders JE
    IEEE Trans Biomed Eng; 2021 Jan; 68(1):36-46. PubMed ID: 32386137
    [TBL] [Abstract][Full Text] [Related]  

  • 8. The modular socket system in a rural setting in Indonesia.
    Giesberts B; Ennion L; Hjelmstrom O; Karma A; Lechler K; Hekman E; Bergsma A
    Prosthet Orthot Int; 2018 Jun; 42(3):336-343. PubMed ID: 29153044
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Adjustable sockets may improve residual limb fluid volume retention in transtibial prosthesis users.
    Brzostowski JT; Larsen BG; Youngblood RT; Ciol MA; Hafner BJ; Gurrey CJ; McLean JB; Allyn KJ; Sanders JE
    Prosthet Orthot Int; 2019 Jun; 43(3):250-256. PubMed ID: 30628522
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Amputee socks: Sock thickness changes with normal use.
    Cagle JC; D'Silva KJ; Hafner BJ; Harrison DS; Sanders JE
    Prosthet Orthot Int; 2016 Jun; 40(3):329-35. PubMed ID: 25733408
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Quantification of rectifications for the Northwestern University Flexible Sub-Ischial Vacuum Socket.
    Fatone S; Johnson WB; Tran L; Tucker K; Mowrer C; Caldwell R
    Prosthet Orthot Int; 2017 Jun; 41(3):251-257. PubMed ID: 28094689
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Osseointegrated Prosthetic Implants for People With Lower-Limb Amputation: A Health Technology Assessment.
    Ontario Health (Quality)
    Ont Health Technol Assess Ser; 2019; 19(7):1-126. PubMed ID: 31911825
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Laboratory and clinical tests of a prototype pressure sensor for clincial assessment of prosthetic socket fit.
    Polliack AA; Craig DD; Sieh RC; Landsberger S; Mcneal DR
    Prosthet Orthot Int; 2002 Apr; 26(1):23-34. PubMed ID: 12043923
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Measuring discomfort-An objective method for quantifying peak pressure discomfort and improved fit in adults with transtibial amputation.
    Binedell T; Ghazali MFB; Wong C; Subburaj K; Blessing L
    PM R; 2023 Apr; 15(4):482-492. PubMed ID: 35233956
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Short partial doffs of release/relock sockets may effectively stabilize limb fluid volume in prosthesis users with transtibial amputation.
    Lanahan CR; Coburn KA; Hafner BJ; Ballesteros D; Allyn KJ; Friedly JL; Ciol MA; Carter RV; Mertens JC; Krout AJ; Sanders JE
    Clin Biomech (Bristol, Avon); 2023 Jun; 106():105986. PubMed ID: 37210769
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Northwestern University Flexible Subischial Vacuum Socket for persons with transfemoral amputation-Part 1: Description of technique.
    Fatone S; Caldwell R
    Prosthet Orthot Int; 2017 Jun; 41(3):237-245. PubMed ID: 28094686
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Assessment of Socket Pressure during Walking in Rapid Fit Prosthetic Sockets.
    Sasaki K; Guerra G; Lei Phyu W; Chaisumritchoke S; Sutdet P; Kaewtip S
    Sensors (Basel); 2022 Jul; 22(14):. PubMed ID: 35890905
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Evaluation of the new, patient-adjustable socket system Varos in the early phase of prosthetic rehabilitation: a pilot study.
    Nia A; Toetschinger G; Kubinec T; Domayer S
    Eur J Phys Rehabil Med; 2022 Jun; 58(3):462-469. PubMed ID: 35148042
    [TBL] [Abstract][Full Text] [Related]  

  • 19. A novel, low-cost transradial socket fabrication method using mass-producible components and expanding rigid foam.
    Miller LA; Pickerill T; Kuiken TA
    Prosthet Orthot Int; 2021 Feb; 45(1):89-93. PubMed ID: 33834750
    [TBL] [Abstract][Full Text] [Related]  

  • 20. A novel portable sensor to monitor bodily positions and activities in transtibial prosthesis users.
    Mertens JC; Brzostowski JT; Vamos A; Allyn KJ; Hafner BJ; Friedly JL; DeGrasse NS; Ballesteros D; Krout A; Larsen BG; Garbini JL; Sanders JE
    Clin Biomech (Bristol, Avon); 2022 Oct; 99():105741. PubMed ID: 36041309
    [TBL] [Abstract][Full Text] [Related]  