These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
218 related articles for article (PubMed ID: 35798901)
1. Sound Induced Vibrations Deform the Organ of Corti Complex in the Low-Frequency Apical Region of the Gerbil Cochlea for Normal Hearing : Sound Induced Vibrations Deform the Organ of Corti Complex. Meenderink SWF; Lin X; Park BH; Dong W J Assoc Res Otolaryngol; 2022 Oct; 23(5):579-591. PubMed ID: 35798901 [TBL] [Abstract][Full Text] [Related]
2. Two-Dimensional Cochlear Micromechanics Measured In Vivo Demonstrate Radial Tuning within the Mouse Organ of Corti. Lee HY; Raphael PD; Xia A; Kim J; Grillet N; Applegate BE; Ellerbee Bowden AK; Oghalai JS J Neurosci; 2016 Aug; 36(31):8160-73. PubMed ID: 27488636 [TBL] [Abstract][Full Text] [Related]
3. Organ of Corti vibration within the intact gerbil cochlea measured by volumetric optical coherence tomography and vibrometry. Dong W; Xia A; Raphael PD; Puria S; Applegate B; Oghalai JS J Neurophysiol; 2018 Dec; 120(6):2847-2857. PubMed ID: 30281386 [TBL] [Abstract][Full Text] [Related]
4. Amplification and Suppression of Traveling Waves along the Mouse Organ of Corti: Evidence for Spatial Variation in the Longitudinal Coupling of Outer Hair Cell-Generated Forces. Dewey JB; Applegate BE; Oghalai JS J Neurosci; 2019 Mar; 39(10):1805-1816. PubMed ID: 30651330 [TBL] [Abstract][Full Text] [Related]
5. Regional differences in cochlear nonlinearity across the basal organ of Corti of gerbil: Regional differences in cochlear nonlinearity. Strimbu CE; Chiriboga LA; Frost BL; Olson ES Hear Res; 2024 Mar; 443():108951. PubMed ID: 38277880 [TBL] [Abstract][Full Text] [Related]
6. Vibration hotspots reveal longitudinal funneling of sound-evoked motion in the mammalian cochlea. Cooper NP; Vavakou A; van der Heijden M Nat Commun; 2018 Aug; 9(1):3054. PubMed ID: 30076297 [TBL] [Abstract][Full Text] [Related]
7. Nonlinearity and amplification in cochlear responses to single and multi-tone stimuli. Fallah E; Strimbu CE; Olson ES Hear Res; 2019 Jun; 377():271-281. PubMed ID: 31015062 [TBL] [Abstract][Full Text] [Related]
8. The origin of mechanical harmonic distortion within the organ of Corti in living gerbil cochleae. He W; Ren T Commun Biol; 2021 Aug; 4(1):1008. PubMed ID: 34433876 [TBL] [Abstract][Full Text] [Related]
9. Noninvasive in vivo imaging reveals differences between tectorial membrane and basilar membrane traveling waves in the mouse cochlea. Lee HY; Raphael PD; Park J; Ellerbee AK; Applegate BE; Oghalai JS Proc Natl Acad Sci U S A; 2015 Mar; 112(10):3128-33. PubMed ID: 25737536 [TBL] [Abstract][Full Text] [Related]
10. Reticular lamina and basilar membrane vibrations in living mouse cochleae. Ren T; He W; Kemp D Proc Natl Acad Sci U S A; 2016 Aug; 113(35):9910-5. PubMed ID: 27516544 [TBL] [Abstract][Full Text] [Related]
11. Asymmetric vibrations in the organ of Corti by outer hair cells measured from excised gerbil cochlea. Lin WC; Macić A; Becker J; Nam JH Commun Biol; 2024 May; 7(1):600. PubMed ID: 38762693 [TBL] [Abstract][Full Text] [Related]
12. Vibration of the organ of Corti within the cochlear apex in mice. Gao SS; Wang R; Raphael PD; Moayedi Y; Groves AK; Zuo J; Applegate BE; Oghalai JS J Neurophysiol; 2014 Sep; 112(5):1192-204. PubMed ID: 24920025 [TBL] [Abstract][Full Text] [Related]
13. Minimal basilar membrane motion in low-frequency hearing. Warren RL; Ramamoorthy S; Ciganović N; Zhang Y; Wilson TM; Petrie T; Wang RK; Jacques SL; Reichenbach T; Nuttall AL; Fridberger A Proc Natl Acad Sci U S A; 2016 Jul; 113(30):E4304-10. PubMed ID: 27407145 [TBL] [Abstract][Full Text] [Related]
14. Optical Coherence Tomography to Measure Sound-Induced Motions Within the Mouse Organ of Corti In Vivo. Jawadi Z; Applegate BE; Oghalai JS Methods Mol Biol; 2016; 1427():449-62. PubMed ID: 27259941 [TBL] [Abstract][Full Text] [Related]
15. An outer hair cell-powered global hydromechanical mechanism for cochlear amplification. He W; Burwood G; Fridberger A; Nuttall AL; Ren T Hear Res; 2022 Sep; 423():108407. PubMed ID: 34922772 [TBL] [Abstract][Full Text] [Related]
16. The effect of tectorial membrane and basilar membrane longitudinal coupling in cochlear mechanics. Meaud J; Grosh K J Acoust Soc Am; 2010 Mar; 127(3):1411-21. PubMed ID: 20329841 [TBL] [Abstract][Full Text] [Related]
17. Contribution of outer hair cell bending to stereocilium deflection in the cochlea. Li H; Lim KM Hear Res; 2007 Oct; 232(1-2):20-8. PubMed ID: 17629426 [TBL] [Abstract][Full Text] [Related]
18. Using volumetric optical coherence tomography to achieve spatially resolved organ of Corti vibration measurements. Frost BL; Strimbu CE; Olson ES J Acoust Soc Am; 2022 Feb; 151(2):1115. PubMed ID: 35232061 [TBL] [Abstract][Full Text] [Related]
19. Vibration responses of the organ of Corti and the tectorial membrane to electrical stimulation. Nowotny M; Gummer AW J Acoust Soc Am; 2011 Dec; 130(6):3852-72. PubMed ID: 22225042 [TBL] [Abstract][Full Text] [Related]