These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

121 related articles for article (PubMed ID: 35813246)

  • 1. Efficient Evaluation of Low-contrast Detectability of Deep-CNN-based CT Reconstruction Using Channelized Hotelling Observer on the ACR Accreditation Phantom.
    Fan M; Zhou Z; Vrieze T; Wang J; McCollough C; Yu L
    Proc SPIE Int Soc Opt Eng; 2022; 12031():. PubMed ID: 35813246
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Accurate and efficient measurement of channelized Hotelling observer-based low-contrast detectability on the ACR CT accreditation phantom.
    Fan M; Thayib T; McCollough C; Yu L
    Med Phys; 2023 Feb; 50(2):737-749. PubMed ID: 36273393
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Channelized hotelling observer-based low-contrast detectability on the ACR CT accreditation phantom: Part II. Repeatability study.
    Fan M; Zhou Z; McCollough C; Yu L
    Med Phys; 2024 Mar; 51(3):1714-1725. PubMed ID: 38305692
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Evaluation of Low-contrast Detectability of Photon-Counting-Detector CT Using Channelized Hotelling Observer and an ACR Accreditation Phantom.
    Fan M; Zhou Z; Bruesewitz M; McCollough C; Yu L
    Proc SPIE Int Soc Opt Eng; 2023 Feb; 12463():. PubMed ID: 37528865
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Use of a channelized Hotelling observer to assess CT image quality and optimize dose reduction for iteratively reconstructed images.
    Favazza CP; Ferrero A; Yu L; Leng S; McMillan KL; McCollough CH
    J Med Imaging (Bellingham); 2017 Jul; 4(3):031213. PubMed ID: 28983493
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Objective assessment of low contrast detectability in computed tomography with Channelized Hotelling Observer.
    Racine D; Ba AH; Ott JG; Bochud FO; Verdun FR
    Phys Med; 2016 Jan; 32(1):76-83. PubMed ID: 26515665
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Prediction of human observer performance in a 2-alternative forced choice low-contrast detection task using channelized Hotelling observer: impact of radiation dose and reconstruction algorithms.
    Yu L; Leng S; Chen L; Kofler JM; Carter RE; McCollough CH
    Med Phys; 2013 Apr; 40(4):041908. PubMed ID: 23556902
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Correlation between a 2D channelized Hotelling observer and human observers in a low-contrast detection task with multislice reading in CT.
    Yu L; Chen B; Kofler JM; Favazza CP; Leng S; Kupinski MA; McCollough CH
    Med Phys; 2017 Aug; 44(8):3990-3999. PubMed ID: 28555878
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Improving Low-contrast Detectability and Noise Texture Pattern for Computed Tomography Using Iterative Reconstruction Accelerated with Machine Learning Method: A Phantom Study.
    Funama Y; Takahashi H; Goto T; Aoki Y; Yoshida R; Kumagai Y; Awai K
    Acad Radiol; 2020 Jul; 27(7):929-936. PubMed ID: 31918961
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Impact of Number of Repeated Scans on Model Observer Performance for a Low-contrast Detection Task in CT.
    Ma C; Yu L; Chen B; Vrieze T; Leng S; McCollough C
    Proc SPIE Int Soc Opt Eng; 2015 Feb; 9416():. PubMed ID: 26146446
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Low-contrast detectability and potential for radiation dose reduction using deep learning image reconstruction-A 20-reader study on a semi-anthropomorphic liver phantom.
    Njølstad T; Jensen K; Dybwad A; Salvesen Ø; Andersen HK; Schulz A
    Eur J Radiol Open; 2022; 9():100418. PubMed ID: 35391822
    [TBL] [Abstract][Full Text] [Related]  

  • 12. A Web-Based Software Platform for Efficient and Quantitative CT Image Quality Assessment and Protocol Optimization.
    Fan M; Thayib T; Ren L; Hsieh S; McCollough C; Holmes D; Yu L
    Proc SPIE Int Soc Opt Eng; 2021 Feb; 11595():. PubMed ID: 33986559
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Automated Web-based Software for CT Quality Control Testing of Low-contrast Detectability using Model Observers.
    Zhou Z; Wellinghoff J; Fan M; Hsieh S; Holmes D; McCollough CH; Yu L
    Proc SPIE Int Soc Opt Eng; 2024 Feb; 12925():. PubMed ID: 38606000
    [TBL] [Abstract][Full Text] [Related]  

  • 14. CT image quality assessment by a Channelized Hotelling Observer (CHO): Application to protocol optimization.
    Noferini L; Taddeucci A; Bartolini M; Bruschi A; Menchi I
    Phys Med; 2016 Dec; 32(12):1717-1723. PubMed ID: 27964873
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Impact of number of repeated scans on model observer performance for a low-contrast detection task in computed tomography.
    Ma C; Yu L; Chen B; Favazza C; Leng S; McCollough C
    J Med Imaging (Bellingham); 2016 Apr; 3(2):023504. PubMed ID: 27284547
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Task-based characterization of a deep learning image reconstruction and comparison with filtered back-projection and a partial model-based iterative reconstruction in abdominal CT: A phantom study.
    Racine D; Becce F; Viry A; Monnin P; Thomsen B; Verdun FR; Rotzinger DC
    Phys Med; 2020 Aug; 76():28-37. PubMed ID: 32574999
    [TBL] [Abstract][Full Text] [Related]  

  • 17. CT head-scan dosimetry in an anthropomorphic phantom and associated measurement of ACR accreditation-phantom imaging metrics under clinically representative scan conditions.
    Brunner CC; Stern SH; Minniti R; Parry MI; Skopec M; Chakrabarti K
    Med Phys; 2013 Aug; 40(8):081917. PubMed ID: 23927331
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Iterative reconstruction with multifrequency signal recognition technology to improve low-contrast detectability: A phantom study.
    Funama Y; Shirasaka T; Goto T; Aoki Y; Tanaka K; Yoshida R
    Acta Radiol Open; 2022 Jun; 11(6):20584601221109919. PubMed ID: 35747445
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Adaptive nonlocal means filtering based on local noise level for CT denoising.
    Li Z; Yu L; Trzasko JD; Lake DS; Blezek DJ; Fletcher JG; McCollough CH; Manduca A
    Med Phys; 2014 Jan; 41(1):011908. PubMed ID: 24387516
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Inter-laboratory comparison of channelized hotelling observer computation.
    Ba A; Abbey CK; Baek J; Han M; Bouwman RW; Balta C; Brankov J; Massanes F; Gifford HC; Hernandez-Giron I; Veldkamp WJH; Petrov D; Marshall N; Samuelson FW; Zeng R; Solomon JB; Samei E; Timberg P; Förnvik H; Reiser I; Yu L; Gong H; Bochud FO
    Med Phys; 2018 Jul; 45(7):3019-3030. PubMed ID: 29704868
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.