These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

138 related articles for article (PubMed ID: 35857252)

  • 21. Finite element and experimental analysis to select patient's bone condition specific porous dental implant, fabricated using additive manufacturing.
    Chakraborty A; Datta P; Majumder S; Mondal SC; Roychowdhury A
    Comput Biol Med; 2020 Sep; 124():103839. PubMed ID: 32763517
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Influence of thread shape and inclination on the biomechanical behaviour of plateau implant systems.
    Calì M; Zanetti EM; Oliveri SM; Asero R; Ciaramella S; Martorelli M; Bignardi C
    Dent Mater; 2018 Mar; 34(3):460-469. PubMed ID: 29395470
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Simulation of impact test for determining "health" of percutaneous bone anchored implants.
    Jones S; Faulkner G; Raboud D; Fyfe K; Wolfaardt J
    J Biomech Eng; 2006 Oct; 128(5):647-53. PubMed ID: 16995750
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Effect of porous orthopaedic implant material and structure on load sharing with simulated bone ingrowth: A finite element analysis comparing titanium and PEEK.
    Carpenter RD; Klosterhoff BS; Torstrick FB; Foley KT; Burkus JK; Lee CSD; Gall K; Guldberg RE; Safranski DL
    J Mech Behav Biomed Mater; 2018 Apr; 80():68-76. PubMed ID: 29414477
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Ultrasonic assessment of osseointegration phenomena at the bone-implant interface using convolutional neural network.
    Kwak Y; Nguyen VH; Hériveaux Y; Belanger P; Park J; Haïat G
    J Acoust Soc Am; 2021 Jun; 149(6):4337. PubMed ID: 34241416
    [TBL] [Abstract][Full Text] [Related]  

  • 26. The effect of implant thread design on stress distribution in anisotropic bone with different osseointegration conditions: a finite element analysis.
    Mosavar A; Ziaei A; Kadkhodaei M
    Int J Oral Maxillofac Implants; 2015; 30(6):1317-26. PubMed ID: 26478976
    [TBL] [Abstract][Full Text] [Related]  

  • 27. A review of improved fixation methods for dental implants. Part II: biomechanical integrity at bone-implant interface.
    Shibata Y; Tanimoto Y; Maruyama N; Nagakura M
    J Prosthodont Res; 2015 Apr; 59(2):84-95. PubMed ID: 25797023
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Three-Dimensional Finite Element Analysis of Osseointegrated Implants Placed in Bone of Different Densities With Cemented Fixed Prosthetic Restoration.
    Chidambaravalli K; Krishnan V
    J Oral Implantol; 2020 Oct; 46(5):480-490. PubMed ID: 32315437
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Design of patient specific bone stiffness mimicking scaffold.
    Rana M; Chaudhuri A; Biswas JK; Karim SI; Datta P; Karmakar SK; Roychowdhury A
    Proc Inst Mech Eng H; 2021 Dec; 235(12):1453-1462. PubMed ID: 34227419
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Stress shielding at the bone-implant interface: Influence of surface roughness and of the bone-implant contact ratio.
    Raffa ML; Nguyen VH; Hernigou P; Flouzat-Lachaniette CH; Haiat G
    J Orthop Res; 2021 Jun; 39(6):1174-1183. PubMed ID: 32852064
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Effect of the material's stiffness on stress-shielding in osseointegrated implants for bone-anchored prostheses: a numerical analysis and initial benchmark data.
    Prochor P; Frossard L; Sajewicz E
    Acta Bioeng Biomech; 2020; 22(2):69-81. PubMed ID: 32868951
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Effects on the torsional vibration behavior in the investigation of dental implant osseointegration using resonance frequency analysis: a numerical approach.
    Zhai M; Li B; Li D
    Med Biol Eng Comput; 2017 Sep; 55(9):1649-1658. PubMed ID: 28176266
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Effects of implant surface roughness and stiffness of grafted bone on an immediately loaded maxillary implant: a 3D numerical analysis.
    Huang HL; Fuh LJ; Hsu JT; Tu MG; Shen YW; Wu CL
    J Oral Rehabil; 2008 Apr; 35(4):283-90. PubMed ID: 18321264
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Modelling the resonant frequency associated with the spatio-temporal evolution of the bone-dental implant interface.
    Gershov S; Xie J; Shah FA; Shemtov-Yona K; Rittel D
    Acta Biomater; 2022 Dec; 154():302-311. PubMed ID: 36306984
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Prediction of insertion torque and stiffness of a dental implant in bovine trabecular bone using explicit micro-finite element analysis.
    Ovesy M; Indermaur M; Zysset PK
    J Mech Behav Biomed Mater; 2019 Oct; 98():301-310. PubMed ID: 31295709
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Novel and simplified optimisation pathway using response surface and design of experiments methodologies for dental implants based on the stress of the cortical bone.
    Freitas JP; Agostinho Hernandez B; Gonçalves PJP; Baptista EC; Capello Sousa EA
    Proc Inst Mech Eng H; 2021 Nov; 235(11):1297-1309. PubMed ID: 34382455
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Three-dimensional finite element analysis of implant stability in the atrophic posterior maxilla: a mathematical study of the sinus floor augmentation.
    Tepper G; Haas R; Zechner W; Krach W; Watzek G
    Clin Oral Implants Res; 2002 Dec; 13(6):657-65. PubMed ID: 12519342
    [TBL] [Abstract][Full Text] [Related]  

  • 38. The influence of implant diameter and length on stress distribution of osseointegrated implants related to crestal bone geometry: a three-dimensional finite element analysis.
    Baggi L; Cappelloni I; Di Girolamo M; Maceri F; Vairo G
    J Prosthet Dent; 2008 Dec; 100(6):422-31. PubMed ID: 19033026
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Modeling the electromechanical impedance technique for the assessment of dental implant stability.
    LaMalfa Ribolla E; Rizzo P
    J Biomech; 2015 Jul; 48(10):1713-20. PubMed ID: 26070645
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Magnitude and direction of mechanical stress at the osseointegrated interface of the microthread implant.
    Hudieb MI; Wakabayashi N; Kasugai S
    J Periodontol; 2011 Jul; 82(7):1061-70. PubMed ID: 21189091
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 7.