These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

126 related articles for article (PubMed ID: 3585783)

  • 1. Computer-aided design of a prosthetic socket for an above-knee amputee.
    Krouskop TA; Muilenberg AL; Doughtery DR; Winningham DJ
    J Rehabil Res Dev; 1987; 24(2):31-8. PubMed ID: 3585783
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Real-time patient-specific finite element analysis of internal stresses in the soft tissues of a residual limb: a new tool for prosthetic fitting.
    Portnoy S; Yarnitzky G; Yizhar Z; Kristal A; Oppenheim U; Siev-Ner I; Gefen A
    Ann Biomed Eng; 2007 Jan; 35(1):120-35. PubMed ID: 17120139
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Interface pressures in above-knee sockets.
    Krouskop TA; Brown J; Goode B; Winningham D
    Arch Phys Med Rehabil; 1987 Oct; 68(10):713-4. PubMed ID: 3662780
    [TBL] [Abstract][Full Text] [Related]  

  • 4. The VA-Cyberware lower limb prosthetics-orthotics optical laser digitizer.
    Houston VL; Mason CP; Beattie AC; LaBlanc KP; Garbarini M; Lorenze EJ; Thongpop CM
    J Rehabil Res Dev; 1995 Feb; 32(1):55-73. PubMed ID: 7760268
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Below knee prosthetic socket designs and suspension systems.
    Edwards ML
    Phys Med Rehabil Clin N Am; 2000 Aug; 11(3):585-93, vi. PubMed ID: 10989480
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Finite element modeling of the contact interface between trans-tibial residual limb and prosthetic socket.
    Lee WC; Zhang M; Jia X; Cheung JT
    Med Eng Phys; 2004 Oct; 26(8):655-62. PubMed ID: 15471693
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Static and dynamic pressure prediction for prosthetic socket fitting assessment utilising an inverse problem approach.
    Sewell P; Noroozi S; Vinney J; Amali R; Andrews S
    Artif Intell Med; 2012 Jan; 54(1):29-41. PubMed ID: 21963113
    [TBL] [Abstract][Full Text] [Related]  

  • 8. State-of-the-art methods for geometric and biomechanical assessments of residual limbs: a review.
    Zheng YP; Mak AF; Leung AK
    J Rehabil Res Dev; 2001; 38(5):487-504. PubMed ID: 11732827
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Computer-aided design and manufacture of an above-knee amputee socket.
    Torres-Moreno R; Saunders CG; Foort J; Morrison JB
    J Biomed Eng; 1991 Jan; 13(1):3-9. PubMed ID: 2002669
    [TBL] [Abstract][Full Text] [Related]  

  • 10. A three-dimensional finite element model of the transibial residual limb and prosthetic socket to predict skin temperatures.
    Peery JT; Klute GK; Blevins JJ; Ledoux WR
    IEEE Trans Neural Syst Rehabil Eng; 2006 Sep; 14(3):336-43. PubMed ID: 17009493
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Nonlinear elastic material property estimation of lower extremity residual limb tissues.
    Tönük E; Silver-Thorn MB
    IEEE Trans Neural Syst Rehabil Eng; 2003 Mar; 11(1):43-53. PubMed ID: 12797725
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Modeling the interactions between a prosthetic socket, polyurethane liners and the residual limb in transtibial amputees using non-linear finite element analysis.
    Simpson G; Fisher C; Wright DK
    Biomed Sci Instrum; 2001; 37():343-7. PubMed ID: 11347414
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Report on the evaluation of the VA/Seattle below-knee prosthesis.
    Ellepola W; Sheredos SJ
    J Rehabil Res Dev; 1993; 30(2):260-6. PubMed ID: 8035354
    [TBL] [Abstract][Full Text] [Related]  

  • 14. [Fast automated finite element mesh generation of residual lower limb for clinical application].
    Jiang WT; Fan YB; Pu F; Zhang M; Zheng YP; Chen JK
    Space Med Med Eng (Beijing); 2002 Aug; 15(4):286-90. PubMed ID: 12425337
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Current concepts in above-knee socket design.
    Michael JW
    Instr Course Lect; 1990; 39():373-8. PubMed ID: 2186127
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Development of an integrated CAD-FEA process for below-knee prosthetic sockets.
    Goh JC; Lee PV; Toh SL; Ooi CK
    Clin Biomech (Bristol, Avon); 2005 Jul; 20(6):623-9. PubMed ID: 15927736
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Incidence of the boundary condition between bone and soft tissue in a finite element model of a transfemoral amputee.
    Ramírez JF; Vélez JA
    Prosthet Orthot Int; 2012 Dec; 36(4):405-14. PubMed ID: 22354886
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Generic, geometric finite element analysis of the transtibial residual limb and prosthetic socket.
    Silver-Thorn MB; Childress DS
    J Rehabil Res Dev; 1997 Apr; 34(2):171-86. PubMed ID: 9108344
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Transfemoral socket design and suspension options.
    Kapp SL
    Phys Med Rehabil Clin N Am; 2000 Aug; 11(3):569-83, vi. PubMed ID: 10989479
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Development of a finite element model of a transtibial socket liner--an initial study.
    Fisher C; Simpson G; Reynolds D
    Biomed Sci Instrum; 1999; 35():39-44. PubMed ID: 11143383
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.