These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

157 related articles for article (PubMed ID: 35861466)

  • 1. Endovascular Rescue Aortic Fenestration After Accidental False Lumen TEVAR in Type B Dissection.
    Massmann A; Giebels C; Buecker A; Schäfers HJ; Fries P
    J Endovasc Ther; 2024 Feb; 31(1):151-156. PubMed ID: 35861466
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Volume analysis of true and false lumens in acute complicated type B aortic dissections after thoracic endovascular aortic repair with stent grafts alone or with a composite device design.
    Sobocinski J; Lombardi JV; Dias NV; Berger L; Zhou Q; Jia F; Resch T; Haulon S
    J Vasc Surg; 2016 May; 63(5):1216-24. PubMed ID: 26806523
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Laser-assisted "Scissor" Technique to Facilitate Thoracic Endovascular Aortic Repair for Chronic Type B Aortic Dissection.
    Qato K; Conway A; Northfield E; Giangola G; Brinster D; Carroccio A
    Ann Vasc Surg; 2021 Nov; 77():347.e7-347.e11. PubMed ID: 34182117
    [TBL] [Abstract][Full Text] [Related]  

  • 4. [The Characteristics of Aortic Remodeling after Thoracic Endovascular Aortic Repair using Two-stent Graft Implantation for Stanford Type B Aortic Dissection].
    Gao YS; Zhang ZM; Jin FX; Dong YH; Jiang WH; Wang DW; Wei YL
    Sichuan Da Xue Xue Bao Yi Xue Ban; 2021 Jan; 52(1):111-116. PubMed ID: 33474899
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Modified Petticoat Technique with Pre-placement of a Distal Bare Stent Improves Early Aortic Remodeling after Complicated Acute Stanford Type B Aortic Dissection.
    He H; Yao K; Nie WP; Wang Z; Liang Q; Shu C; Dardik A
    Eur J Vasc Endovasc Surg; 2015 Oct; 50(4):450-9. PubMed ID: 26100449
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Satisfactory Long-term Outcomes of Thoracic Endovascular Aortic Repair With a Bare Stent for Acute Complicated Type B Aortic Dissections.
    Lin Y; Dong S; Luo J; Bei W; Liu Q; Pang X; Liu H
    J Endovasc Ther; 2021 Apr; 28(2):275-282. PubMed ID: 33118433
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Patient outcomes and thoracic aortic volume and morphologic changes following thoracic endovascular aortic repair in patients with complicated chronic type B aortic dissection.
    Andacheh ID; Donayre C; Othman F; Walot I; Kopchok G; White R
    J Vasc Surg; 2012 Sep; 56(3):644-50; discussion 650. PubMed ID: 22640467
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Aortic remodelling and late outcomes following thoracic endovascular repair with a bare-metal stent distal extension among patients with complicated type-B aortic dissection.
    Wamala I; Nazari-Shafti MTZ; Heck R; Penkalla A; Montagner M; Staffa SJ; Falk V; Buz S
    Interact Cardiovasc Thorac Surg; 2022 Oct; 35(5):. PubMed ID: 36149286
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Thoracic Endovascular Aortic Repair on Zone 2 Landing for Uncomplicated Type B Aortic Dissection with Measurement of Intra-False Lumen Pressure.
    Miura S; Kurimoto Y; Maruyama R; Yamamoto M; Fusegawa M; Sasaki K; Masuda T; Nishioka N; Naraoka S
    Ann Vasc Surg; 2024 Jan; 98():137-145. PubMed ID: 37355017
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Adjunctive endovascular balloon fracture fenestration for chronic aortic dissection.
    Levack MM; Kindzelski BA; Miletic KG; Vargo PR; Bakaeen FG; Johnston DR; Rajeswaran J; Blackstone EH; Roselli EE
    J Thorac Cardiovasc Surg; 2022 Jul; 164(1):2-10.e5. PubMed ID: 33220972
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Improved Remodeling With TEVAR and Distal Bare-Metal Stent in Acute Complicated Type B Dissection.
    Nienaber CA; Yuan X; Aboukoura M; Blanke P; Jakob R; Janosi RA; Lovato L; Riambau V; Trebacz J; Trimarchi S; Zipfel B; van den Berg JC;
    Ann Thorac Surg; 2020 Nov; 110(5):1572-1579. PubMed ID: 32205112
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Combined proximal descending aortic endografting plus distal bare metal stenting (PETTICOAT technique) versus conventional proximal descending aortic stent graft repair for complicated type B aortic dissections.
    Rong D; Ge Y; Liu J; Liu X; Guo W
    Cochrane Database Syst Rev; 2019 Oct; 2019(10):. PubMed ID: 31684692
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Fate and Consequences of the False Lumen After Thoracic Endovascular Aortic Repair in Type B Aortic Dissection.
    Jubouri M; Patel R; Tan SZ; Al-Tawil M; Bashir M; Bailey DM; Williams IM
    Ann Vasc Surg; 2023 Aug; 94():32-37. PubMed ID: 36309167
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Initial Single-Center Experience With the Knickerbocker Technique During Thoracic Endovascular Aortic Repair to Block Retrograde False Lumen Flow in Patients With Type B Aortic Dissection.
    de Beaufort HWL; Vos JA; Heijmen RH
    J Endovasc Ther; 2022 Nov; ():15266028221134889. PubMed ID: 36342189
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Thoracic endovascular aortic repair for retrograde type A aortic dissection with an entry tear in the descending aorta.
    Shu C; Wang T; Li QM; Li M; Jiang XH; Luo MY; Li X
    J Vasc Interv Radiol; 2012 Apr; 23(4):453-60, 460.e1. PubMed ID: 22464711
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Thoracic endovascular aortic repair with stent grafts alone or with a composite device design in patients with acute type B aortic dissection in the setting of malperfusion.
    Sobocinski J; Dias NV; Hongku K; Lombardi JV; Zhou Q; Saunders AT; Resch T; Haulon S
    J Vasc Surg; 2020 Feb; 71(2):400-407.e2. PubMed ID: 31280979
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Clinical comparative analysis of 3D printing-assisted extracorporeal pre-fenestration and Castor integrated branch stent techniques in treating type B aortic dissections with inadequate proximal landing zones.
    Zheng R; Xi H; Zhu F; Cheng C; Huang W; Zhang H; He X; Shen K; Liu Y; Lu Q; Yu H
    BMC Cardiovasc Disord; 2024 Feb; 24(1):124. PubMed ID: 38408908
    [TBL] [Abstract][Full Text] [Related]  

  • 18. [Clinical Experience of Endovascular Stent-graft Treatment for Stanford Type A Acute Aortic Dissection].
    Uchida T; Kuroda Y; Yamashita A; Hamasaki A; Hirooka S; Nakai S; Kobayashi K; Sadahiro M
    Kyobu Geka; 2019 Nov; 72(12):976-983. PubMed ID: 31701906
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Volumetric analysis of type B aortic dissections treated with thoracic endovascular aortic repair.
    Stanley GA; Murphy EH; Knowles M; Ilves M; Jessen ME; Dimaio JM; Modrall JG; Arko FR
    J Vasc Surg; 2011 Oct; 54(4):985-92; discussion 992. PubMed ID: 21917398
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Late aortic remodeling persists in the stented segment after endovascular repair of acute complicated type B aortic dissection.
    Conrad MF; Carvalho S; Ergul E; Kwolek CJ; Lancaster RT; Patel VI; Cambria RP
    J Vasc Surg; 2015 Sep; 62(3):600-5. PubMed ID: 26054588
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.