These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
265 related articles for article (PubMed ID: 35869866)
21. Head and neck synthetic CT generated from ultra-low-dose cone-beam CT following Image Gently Protocol using deep neural network. Yuan N; Rao S; Chen Q; Sensoy L; Qi J; Rong Y Med Phys; 2022 May; 49(5):3263-3277. PubMed ID: 35229904 [TBL] [Abstract][Full Text] [Related]
22. Performance validation of deformable image registration in the pelvic region. Zambrano V; Furtado H; Fabri D; Lütgendorf-Caucig C; Góra J; Stock M; Mayer R; Birkfellner W; Georg D J Radiat Res; 2013 Jul; 54 Suppl 1(Suppl 1):i120-8. PubMed ID: 23824115 [TBL] [Abstract][Full Text] [Related]
23. Toward adaptive radiotherapy for head and neck patients: Feasibility study on using CT-to-CBCT deformable registration for "dose of the day" calculations. Veiga C; McClelland J; Moinuddin S; Lourenço A; Ricketts K; Annkah J; Modat M; Ourselin S; D'Souza D; Royle G Med Phys; 2014 Mar; 41(3):031703. PubMed ID: 24593707 [TBL] [Abstract][Full Text] [Related]
24. Predicting dice similarity coefficient of deformably registered contours using Siamese neural network. Yeap PL; Wong YM; Ong ALK; Tuan JKL; Pang EPP; Park SY; Lee JCL; Tan HQ Phys Med Biol; 2023 Jul; 68(15):. PubMed ID: 37437590 [No Abstract] [Full Text] [Related]
25. A virtual phantom library for the quantification of deformable image registration uncertainties in patients with cancers of the head and neck. Pukala J; Meeks SL; Staton RJ; Bova FJ; Mañon RR; Langen KM Med Phys; 2013 Nov; 40(11):111703. PubMed ID: 24320411 [TBL] [Abstract][Full Text] [Related]
26. Open source deformable image registration system for treatment planning and recurrence CT scans : Validation in the head and neck region. Zukauskaite R; Brink C; Hansen CR; Bertelsen A; Johansen J; Grau C; Eriksen JG Strahlenther Onkol; 2016 Aug; 192(8):545-51. PubMed ID: 27323754 [TBL] [Abstract][Full Text] [Related]
27. Comprehensive evaluation of ten deformable image registration algorithms for contour propagation between CT and cone-beam CT images in adaptive head & neck radiotherapy. Li X; Zhang Y; Shi Y; Wu S; Xiao Y; Gu X; Zhen X; Zhou L PLoS One; 2017; 12(4):e0175906. PubMed ID: 28414799 [TBL] [Abstract][Full Text] [Related]
28. Seq2Morph: A deep learning deformable image registration algorithm for longitudinal imaging studies and adaptive radiotherapy. Lee D; Alam S; Jiang J; Cervino L; Hu YC; Zhang P Med Phys; 2023 Feb; 50(2):970-979. PubMed ID: 36303270 [TBL] [Abstract][Full Text] [Related]
29. Deep learning based direct segmentation assisted by deformable image registration for cone-beam CT based auto-segmentation for adaptive radiotherapy. Liang X; Morgan H; Bai T; Dohopolski M; Nguyen D; Jiang S Phys Med Biol; 2023 Feb; 68(4):. PubMed ID: 36657169 [TBL] [Abstract][Full Text] [Related]
30. Accuracy of low-dose proton CT image registration for pretreatment alignment verification in reference to planning proton CT. Cassetta R; Piersimoni P; Riboldi M; Giacometti V; Bashkirov V; Baroni G; Ordonez C; Coutrakon G; Schulte R J Appl Clin Med Phys; 2019 Apr; 20(4):83-90. PubMed ID: 30933433 [TBL] [Abstract][Full Text] [Related]
31. An adaptive motion regularization technique to support sliding motion in deformable image registration. Fu Y; Liu S; Li HH; Li H; Yang D Med Phys; 2018 Feb; 45(2):735-747. PubMed ID: 29251777 [TBL] [Abstract][Full Text] [Related]
32. Evaluation of the geometric and dosimetric accuracies of deformable image registration of targets and critical organs in prostate CBCT-guided adaptive radiotherapy. Jassim HH; Nedaie HA; Banaee N; Geraily G; Kazemian A; Makrani DS J Appl Clin Med Phys; 2024 Nov; 25(11):e14490. PubMed ID: 39270157 [TBL] [Abstract][Full Text] [Related]
33. Evaluation of the accuracy of deformable image registration on MRI with a physical phantom. Wu RY; Liu AY; Yang J; Williamson TD; Wisdom PG; Bronk L; Gao S; Grosshan DR; Fuller DC; Gunn GB; Ronald Zhu X; Frank SJ J Appl Clin Med Phys; 2020 Jan; 21(1):166-173. PubMed ID: 31808307 [TBL] [Abstract][Full Text] [Related]
34. Multiatlas approach with local registration goodness weighting for MRI-based electron density mapping of head and neck anatomy. Farjam R; Tyagi N; Veeraraghavan H; Apte A; Zakian K; Hunt MA; Deasy JO Med Phys; 2017 Jul; 44(7):3706-3717. PubMed ID: 28444772 [TBL] [Abstract][Full Text] [Related]
35. Dosimetric comparison of deformable image registration and synthetic CT generation based on CBCT images for organs at risk in cervical cancer radiotherapy. Chang Y; Liang Y; Yang B; Qiu J; Pei X; Xu XG Radiat Oncol; 2023 Jan; 18(1):3. PubMed ID: 36604687 [TBL] [Abstract][Full Text] [Related]
36. Assessing the impact of choosing different deformable registration algorithms on cone-beam CT enhancement by histogram matching. Kidar HS; Azizi H Radiat Oncol; 2018 Nov; 13(1):217. PubMed ID: 30404657 [TBL] [Abstract][Full Text] [Related]
37. Synthetic CT generation from MRI using 3D transformer-based denoising diffusion model. Pan S; Abouei E; Wynne J; Chang CW; Wang T; Qiu RLJ; Li Y; Peng J; Roper J; Patel P; Yu DS; Mao H; Yang X Med Phys; 2024 Apr; 51(4):2538-2548. PubMed ID: 38011588 [TBL] [Abstract][Full Text] [Related]
38. Variability in commercially available deformable image registration: A multi-institution analysis using virtual head and neck phantoms. Kubli A; Pukala J; Shah AP; Kelly P; Langen KM; Bova FJ; Mañon RR; Meeks SL J Appl Clin Med Phys; 2021 May; 22(5):89-96. PubMed ID: 33783960 [TBL] [Abstract][Full Text] [Related]
39. Comparison of CBCT based synthetic CT methods suitable for proton dose calculations in adaptive proton therapy. Thummerer A; Zaffino P; Meijers A; Marmitt GG; Seco J; Steenbakkers RJHM; Langendijk JA; Both S; Spadea MF; Knopf AC Phys Med Biol; 2020 Apr; 65(9):095002. PubMed ID: 32143207 [TBL] [Abstract][Full Text] [Related]
40. Validation of an MR-guided online adaptive radiotherapy (MRgoART) program: Deformation accuracy in a heterogeneous, deformable, anthropomorphic phantom. Mittauer KE; Hill PM; Bassetti MF; Bayouth JE Radiother Oncol; 2020 May; 146():97-109. PubMed ID: 32146260 [TBL] [Abstract][Full Text] [Related] [Previous] [Next] [New Search]