These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

173 related articles for article (PubMed ID: 35882159)

  • 21. Effect of porous orthopaedic implant material and structure on load sharing with simulated bone ingrowth: A finite element analysis comparing titanium and PEEK.
    Carpenter RD; Klosterhoff BS; Torstrick FB; Foley KT; Burkus JK; Lee CSD; Gall K; Guldberg RE; Safranski DL
    J Mech Behav Biomed Mater; 2018 Apr; 80():68-76. PubMed ID: 29414477
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Fabrication of porous-Ti6Al4V alloy by using hot pressing technique and Mg space holder for hard-tissue biomedical applications.
    Aslan N; Aksakal B; Findik F
    J Mater Sci Mater Med; 2021 Jun; 32(7):80. PubMed ID: 34191138
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Formability and mechanical properties of porous titanium produced by a moldless process.
    Naito Y; Bae J; Tomotake Y; Hamada K; Asaoka K; Ichikawa T
    J Biomed Mater Res B Appl Biomater; 2013 Aug; 101(6):1090-4. PubMed ID: 23559484
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Mechanical and Biological Properties of a Biodegradable Mg-Zn-Ca Porous Alloy.
    Zhang YQ; Li Y; Liu H; Bai J; Bao NR; Zhang Y; He P; Zhao JN; Tao L; Xue F; Zhou GX; Fan GT
    Orthop Surg; 2018 May; 10(2):160-168. PubMed ID: 29767463
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Direct 3-D printing of Ti-6Al-4V/HA composite porous scaffolds for customized mechanical properties and biological functions.
    Yi T; Zhou C; Ma L; Wu L; Xu X; Gu L; Fan Y; Xian G; Fan H; Zhang X
    J Tissue Eng Regen Med; 2020 Mar; 14(3):486-496. PubMed ID: 32012461
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Evaluation of mechanical properties of Ti-25Nb BCC porous cell structure and their association with structure porosity: A combined finite element analysis and analytical approach for orthopedic application.
    Chowdhury S; Anand A; Singh A; Pal B
    Proc Inst Mech Eng H; 2021 Jul; 235(7):827-837. PubMed ID: 33899579
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Microstructure and compression properties of 3D powder printed Ti-6Al-4V scaffolds with designed porosity: Experimental and computational analysis.
    Barui S; Chatterjee S; Mandal S; Kumar A; Basu B
    Mater Sci Eng C Mater Biol Appl; 2017 Jan; 70(Pt 1):812-823. PubMed ID: 27770959
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Functionally graded porous scaffolds made of Ti-based agglomerates.
    Nazari KA; Hilditch T; Dargusch MS; Nouri A
    J Mech Behav Biomed Mater; 2016 Oct; 63():157-163. PubMed ID: 27389321
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Potential use of porous titanium-niobium alloy in orthopedic implants: preparation and experimental study of its biocompatibility in vitro.
    Xu J; Weng XJ; Wang X; Huang JZ; Zhang C; Muhammad H; Ma X; Liao QD
    PLoS One; 2013; 8(11):e79289. PubMed ID: 24260188
    [TBL] [Abstract][Full Text] [Related]  

  • 30. The effect of scaffold architecture on properties of direct 3D fiber deposition of porous Ti6Al4V for orthopedic implants.
    Li JP; de Wijn JR; van Blitterswijk CA; de Groot K
    J Biomed Mater Res A; 2010 Jan; 92(1):33-42. PubMed ID: 19165798
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Biocompatible porous titanium scaffolds produced using a novel space holder technique.
    Chen Y; Frith JE; Dehghan-Manshadi A; Kent D; Bermingham M; Dargusch M
    J Biomed Mater Res B Appl Biomater; 2018 Nov; 106(8):2796-2806. PubMed ID: 29405558
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Design and Compressive Fatigue Properties of Irregular Porous Scaffolds for Orthopedics Fabricated Using Selective Laser Melting.
    Zhu L; Liang H; Lv F; Xie D; Wang C; Mao Y; Yang Y; Tian Z; Shen L
    ACS Biomater Sci Eng; 2021 Apr; 7(4):1663-1672. PubMed ID: 33682413
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Mechanical properties and biocompatibility of porous titanium scaffolds for bone tissue engineering.
    Chen Y; Frith JE; Dehghan-Manshadi A; Attar H; Kent D; Soro NDM; Bermingham MJ; Dargusch MS
    J Mech Behav Biomed Mater; 2017 Nov; 75():169-174. PubMed ID: 28734258
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Physical and mechanical characterisation of 3D-printed porous titanium for biomedical applications.
    El-Hajje A; Kolos EC; Wang JK; Maleksaeedi S; He Z; Wiria FE; Choong C; Ruys AJ
    J Mater Sci Mater Med; 2014 Nov; 25(11):2471-80. PubMed ID: 25052736
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Finite element analysis of mechanical behavior, permeability and fluid induced wall shear stress of high porosity scaffolds with gyroid and lattice-based architectures.
    Ali D; Sen S
    J Mech Behav Biomed Mater; 2017 Nov; 75():262-270. PubMed ID: 28759838
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Effect of Pore Size and Porosity on the Biomechanical Properties and Cytocompatibility of Porous NiTi Alloys.
    Jian YT; Yang Y; Tian T; Stanford C; Zhang XP; Zhao K
    PLoS One; 2015; 10(6):e0128138. PubMed ID: 26047515
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Processing optimization, mechanical properties, corrosion behavior and cytocompatibility of additively manufactured Zn-0.7Li biodegradable metals.
    Qin Y; Yang H; Liu A; Dai J; Wen P; Zheng Y; Tian Y; Li S; Wang X
    Acta Biomater; 2022 Apr; 142():388-401. PubMed ID: 35085796
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Microstructure, mechanical properties, degradation behavior, and biocompatibility of porous Fe-Mn alloys fabricated by sponge impregnation and sintering techniques.
    Liu P; Zhang D; Dai Y; Lin J; Li Y; Wen C
    Acta Biomater; 2020 Sep; 114():485-496. PubMed ID: 32738505
    [TBL] [Abstract][Full Text] [Related]  

  • 39. [Three-dimensional finite element analysis of the stress distribution of bone tissue around porous titanium implant].
    Liu TS; Gao R; Wei T; Sun HQ
    Zhonghua Kou Qiang Yi Xue Za Zhi; 2019 Jan; 54(1):35-40. PubMed ID: 30630257
    [No Abstract]   [Full Text] [Related]  

  • 40. Properties of a porous Ti-6Al-4V implant with a low stiffness for biomedical application.
    Li X; Wang CT; Zhang WG; Li YC
    Proc Inst Mech Eng H; 2009 Feb; 223(2):173-8. PubMed ID: 19278194
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 9.