These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

148 related articles for article (PubMed ID: 35897946)

  • 1. Development of a Gas-Tight Syringe Headspace GC-FID Method for the Detection of Ethanol, and a Description of the Legal and Practical Framework for Its Analysis, in Samples of English and Welsh Motorists' Blood and Urine.
    Taylor L; Saskőy L; Brodie T; Remeškevičius V; Moir HJ; Barker J; Fletcher J; Kaur Thatti B; Trotter G; Rooney B
    Molecules; 2022 Jul; 27(15):. PubMed ID: 35897946
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Development and Validation of a Method for Alcohol Analysis in Brain Tissue by Headspace Gas Chromatography with Flame Ionization Detector.
    Chun HJ; Poklis JL; Poklis A; Wolf CE
    J Anal Toxicol; 2016 Oct; 40(8):653-658. PubMed ID: 27488829
    [TBL] [Abstract][Full Text] [Related]  

  • 3. The application of headspace gas chromatographic method for the determination of ethyl alcohol in craft beers, wines and soft drinks.
    Wachełko O; Szpot P; Zawadzki M
    Food Chem; 2021 Jun; 346():128924. PubMed ID: 33429297
    [TBL] [Abstract][Full Text] [Related]  

  • 4. [A headspace injection double-column dual-detector gas chromatography system for the analysis of 12 volatile compounds such as ethanol in human blood].
    Zheng QY; Zhi YJ; Duan W; Lü M; Xiao Y; Xiang P; Chen H; Yun K
    Se Pu; 2024 Sep; 42(9):909-917. PubMed ID: 39198950
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Ethanol analysis from biological samples by dual rail robotic autosampler.
    Morris-Kukoski CL; Jagerdeo E; Schaff JE; LeBeau MA
    J Chromatogr B Analyt Technol Biomed Life Sci; 2007 May; 850(1-2):230-5. PubMed ID: 17223393
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Interference of anesthetics in blood alcohol analysis by HS-GC-FID: A case report.
    Monteiro C; Proença P; Tavares C; Castañera A; Corte Real F
    Forensic Sci Int; 2016 Aug; 265():65-9. PubMed ID: 26829337
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A novel simple and precise method for the determination of azide impurity in sartans using headspace gas chromatography with two dissimilar capillary columns and two flame ionization detectors (HS-GC-FID/FID).
    Wachełko O; Szpot P; Zawadzki M
    J Pharm Biomed Anal; 2021 Jan; 192():113671. PubMed ID: 33099116
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Qualitative and quantitative analysis of a group of volatile organic compounds in biological samples by HS-GC/FID: application in practical cases.
    Monteiro C; Franco JM; Proença P; Castañera A; Claro A; Vieira DN; Corte-Real F
    Forensic Sci Int; 2014 Oct; 243():137-43. PubMed ID: 25124884
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Quantifying Ethanol in Ethanol-Based Hand Sanitizers by Headspace Gas Chromatography with Flame Ionization Detector (HS-GC/FID).
    Costa BRBD; Haddad LPE; Caleffo Piva Bigão VL; Martinis BS
    J AOAC Int; 2022 Feb; 105(1):11-18. PubMed ID: 34546367
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Ethanol concentration in 56 refillable electronic cigarettes liquid formulations determined by headspace gas chromatography with flame ionization detector (HS-GC-FID).
    Poklis JL; Wolf CE; Peace MR
    Drug Test Anal; 2017 Oct; 9(10):1637-1640. PubMed ID: 28332307
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Rising above helium: A hydrogen carrier gas chromatography flame ionization detection (GC-FID) method for the simultaneous quantification of toxic alcohols and ethylene glycol in human plasma specimens.
    Buse J; Robinson JL; Shyne R; Chi Q; Affleck D; Duce D; Seiden-Long I
    Clin Biochem; 2019 Nov; 73():98-104. PubMed ID: 31425671
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Development and Validation of an Analytical Method for Volatiles with Endogenous Production in Putrefaction and Submersion Situations.
    Pinto M; Eusébio E; Monteiro C
    J Anal Toxicol; 2021 Nov; 45(9):961-968. PubMed ID: 33031530
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Ethanol analysis by headspace gas chromatography with simultaneous flame-ionization and mass spectrometry detection.
    Tiscione NB; Alford I; Yeatman DT; Shan X
    J Anal Toxicol; 2011 Sep; 35(7):501-11. PubMed ID: 21871160
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Assay of ethanol and congener alcohols in serum and beverages by headspace gas chromatography/mass spectrometry.
    Wunder C; Pogoda W; Paulke A; Toennes SW
    MethodsX; 2021; 8():101563. PubMed ID: 34754825
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Headspace versus direct injection for the quantitation of methanol, ethyl acetate, and fusel oils in distilled spirits by gas chromatography - Flame ionization detection.
    Owens JE; Lowe LE
    MethodsX; 2023 Dec; 11():102387. PubMed ID: 37786837
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Determination of Ethanol Content in Kombucha Products by Gas Chromatography with Flame Ionization Detection: A Multilaboratory Study.
    Liu Y; Chan M; Blake E; Sy H; Brown PN
    J AOAC Int; 2019 May; 102(3):878-882. PubMed ID: 30227904
    [No Abstract]   [Full Text] [Related]  

  • 17. Quantitation and identification of ethanol and inhalant compounds in whole blood using static headspace gas chromatography vacuum ultraviolet spectroscopy.
    Diekmann JA; Cochran J; Hodgson JA; Smuts DJ
    J Chromatogr A; 2020 Jan; 1611():460607. PubMed ID: 31668865
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Simultaneous determination of methanol, acetaldehyde, acetone, and ethanol in human blood by gas chromatography with flame ionization detection.
    Schlatter J; Chiadmi F; Gandon V; Chariot P
    Hum Exp Toxicol; 2014 Jan; 33(1):74-80. PubMed ID: 23584355
    [TBL] [Abstract][Full Text] [Related]  

  • 19. A Single-Column Gas Chromatography Method for Quantifying Toxic Alcohols.
    Kemble DJ; Cervinski MA
    J Appl Lab Med; 2020 Mar; 5(2):300-310. PubMed ID: 32445388
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Headspace gas chromatographic determination of ethanol: the use of factorial design to study effects of blood storage and headspace conditions on ethanol stability and acetaldehyde formation in whole blood and plasma.
    Kristoffersen L; Stormyhr LE; Smith-Kielland A
    Forensic Sci Int; 2006 Sep; 161(2-3):151-7. PubMed ID: 16843627
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.