These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

192 related articles for article (PubMed ID: 35898059)

  • 21. High-frequency annular array fabrication using a flex circuit matching layer.
    Lay HS; Simpson EA; Griffin G; Lockwood GR
    Ultrason Imaging; 2012 Jul; 34(3):196-204. PubMed ID: 22972915
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Analysis of Negative Capacitance-Based Broadband Impedance Matching for CMUTs.
    Rezvanitabar A; Arkan EF; Degertekin FL
    IEEE Trans Ultrason Ferroelectr Freq Control; 2021 Sep; 68(9):3042-3052. PubMed ID: 33983883
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Development of a Small-Footprint 50 MHz Linear Array: Fabrication and Micro-Ultrasound Imaging Demonstration.
    Roa CF; Chérin E; Singh N; Yin J; Boyes A; Foster FS; Demore CEM
    Sensors (Basel); 2024 Mar; 24(6):. PubMed ID: 38544110
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Modelling of a novel high-impedance matching layer for high frequency (>30 MHz) ultrasonic transducers.
    Qian Y; Harris NR
    Ultrasonics; 2014 Feb; 54(2):586-91. PubMed ID: 24025461
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Design and characterization of a high-power ultrasound driver with ultralow-output impedance.
    Lewis GK; Olbricht WL
    Rev Sci Instrum; 2009 Nov; 80(11):114704. PubMed ID: 19947748
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Polarization Inverted Ultrasound Transducer Based on Composite Structure for Tissue Harmonic and Frequency Compound Imaging.
    Choi BE; Lee HS; Sung JH; Jeong EY; Park CY; Jeong JS
    IEEE Trans Ultrason Ferroelectr Freq Control; 2022 Jan; 69(1):273-282. PubMed ID: 34464259
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Mass-spring matching layers for high-frequency ultrasound transducers: a new technique using vacuum deposition.
    Brown J; Sharma S; Leadbetter J; Cochran S; Adamson R
    IEEE Trans Ultrason Ferroelectr Freq Control; 2014 Nov; 61(11):1911-21. PubMed ID: 25389169
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Improving APT Systems' Performance in Air via Impedance Matching and 3D-Printed Clamp.
    Liu L; Abdulla W
    Sensors (Basel); 2023 Jun; 23(11):. PubMed ID: 37300074
    [TBL] [Abstract][Full Text] [Related]  

  • 29. A Rapid Prototyping Method for Sub-MHz Single-Element Piezoelectric Transducers by Using 3D-Printed Components.
    Kim J; Menichella B; Lee H; Dayton PA; Pinton GF
    Sensors (Basel); 2022 Dec; 23(1):. PubMed ID: 36616910
    [TBL] [Abstract][Full Text] [Related]  

  • 30. A Phase-Canceled Backing Layer for Ultrasound Linear Array Transducer: Modeling and Experimental Verification.
    Kwon DS; Sung JH; Park CY; Jeong EY; Jeong JS
    IEEE Trans Ultrason Ferroelectr Freq Control; 2020 Apr; 67(4):770-778. PubMed ID: 31689189
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Input impedance matching of acoustic transducers operating at off-resonant frequencies.
    Son KT; Lee CC
    IEEE Trans Ultrason Ferroelectr Freq Control; 2010 Dec; 57(12):2784-94. PubMed ID: 21156374
    [TBL] [Abstract][Full Text] [Related]  

  • 32. AZ31B magnesium alloy matching layer for Lens-focused piezoelectric transducer application.
    Sun Y; Tao J; Guo F; Wang F; Dong J; Jin L; Li S; Huang X
    Ultrasonics; 2023 Jan; 127():106844. PubMed ID: 36095851
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Development of a Dual-Layer Structure for Cymbal Transducer Arrays to Achieve a Wider Bandwidth.
    Mudiyala J; Shim H; Kim D; Roh Y
    Sensors (Basel); 2022 Sep; 22(17):. PubMed ID: 36081070
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Bonding and impedance matching of acoustic transducers using silver epoxy.
    Son KT; Lee CC
    Ultrasonics; 2012 Apr; 52(4):555-63. PubMed ID: 22239830
    [TBL] [Abstract][Full Text] [Related]  

  • 35. An ultrasensitive and broadband transparent ultrasound transducer for ultrasound and photoacoustic imaging in-vivo.
    Cho S; Kim M; Ahn J; Kim Y; Lim J; Park J; Kim HH; Kim WJ; Kim C
    Nat Commun; 2024 Feb; 15(1):1444. PubMed ID: 38365897
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Underwater single crystal piezocomposite transducer with extended usable frequency band.
    Sagaas Røed E; Bring M; Frijlink M; Henriksen A; Tichy F; Åsjord EM; Hoff L
    Ultrasonics; 2022 Sep; 125():106794. PubMed ID: 35752020
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Experimental analysis of 1-3 piezocomposites for high-intensity focused ultrasound transducer applications.
    Chen GS; Liu HC; Lin YC; Lin YL
    IEEE Trans Biomed Eng; 2013 Jan; 60(1):128-34. PubMed ID: 23193224
    [TBL] [Abstract][Full Text] [Related]  

  • 38. A high-frequency annular-array transducer using an interdigital bonded 1-3 composite.
    Chabok HR; Cannata JM; Kim HH; Williams JA; Park J; Shung KK
    IEEE Trans Ultrason Ferroelectr Freq Control; 2011 Jan; 58(1):206-14. PubMed ID: 21244988
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Fabrication and performance of endoscopic ultrasound radial arrays based on PMN-PT single crystal/epoxy 1-3 composite.
    Zhou D; Cheung KF; Chen Y; Lau ST; Zhou Q; Shung KK; Luo HS; Dai J; Chan HL
    IEEE Trans Ultrason Ferroelectr Freq Control; 2011 Feb; 58(2):477-84. PubMed ID: 21342833
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Impedance matching network for high frequency ultrasonic transducer for cellular applications.
    Kim MG; Yoon S; Kim HH; Shung KK
    Ultrasonics; 2016 Feb; 65():258-67. PubMed ID: 26442434
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 10.