139 related articles for article (PubMed ID: 35898842)
1. Hemostasis using a covered self-expandable metal stent for pseudoaneurysm bleeding from the perihilar bile duct.
Ishii Y; Nakayama A; Kikuchi K; Nakatani K; Konda K; Mori D; Nishihara S; Oikawa S; Nomoto T; Usami T; Noguchi T; Mitsui Y; Yoshida H
DEN Open; 2023 Apr; 3(1):e150. PubMed ID: 35898842
[TBL] [Abstract][Full Text] [Related]
2. Endoscopic Transpapillary Gallbladder Drainage for Acute Cholecystitis After Biliary Self-Expandable Metal Stent Placement.
Nakahara K; Morita R; Michikawa Y; Suetani K; Morita N; Fujita A; Sato J; Igarashi Y; Ikeda H; Matsunaga K; Watanabe T; Kobayashi S; Otsubo T; Itoh F
Surg Laparosc Endosc Percutan Tech; 2020 Oct; 30(5):416-423. PubMed ID: 32398448
[TBL] [Abstract][Full Text] [Related]
3. Ruptured cystic artery pseudoaneurysm after self-expandable metal stent placement for malignant biliary obstruction.
Mie T; Sasaki T; Matsueda K; Okamoto T; Hirai T; Ishitsuka T; Yamada M; Nakagawa H; Furukawa T; Takeda T; Kasuga A; Ozaka M; Sasahira N
DEN Open; 2024 Apr; 4(1):e304. PubMed ID: 37900613
[TBL] [Abstract][Full Text] [Related]
4. Endoscopic transpapillary gallbladder drainage with replacement of a covered self-expandable metal stent.
Kawakubo K; Isayama H; Sasahira N; Nakai Y; Kogure H; Sasaki T; Hirano K; Tada M; Koike K
World J Gastrointest Endosc; 2011 Feb; 3(2):46-8. PubMed ID: 21403817
[TBL] [Abstract][Full Text] [Related]
5. Novel flower-type covered metal stent to prevent cholecystitis: experimental study in a pig model.
Woo YS; Lee KH; Lee JK; Noh DH; Park JK; Lee KT; Jang KT
Surg Endosc; 2016 Mar; 30(3):1141-5. PubMed ID: 26123330
[TBL] [Abstract][Full Text] [Related]
6. Biliary hemostasis using an endoscopic plastic stent placement for uncontrolled hemobilia caused by transpapillary forceps biopsy (with video).
Shinjo K; Matsubayashi H; Matsui T; Kawata N; Uemura S; Yamamoto Y; Ono H
Clin J Gastroenterol; 2016 Apr; 9(2):86-8. PubMed ID: 26960930
[TBL] [Abstract][Full Text] [Related]
7. Practical Experiences of Unsuccessful Hemostasis with Covered Self-Expandable Metal Stent Placement for Post-Endoscopic Sphincterotomy Bleeding.
Yoshida M; Inoue T; Naitoh I; Hayashi K; Hori Y; Natsume M; Atsuta N; Kataoka H
Clin Endosc; 2022 Jan; 55(1):150-155. PubMed ID: 33207403
[TBL] [Abstract][Full Text] [Related]
8. Hepatic artery pseudoaneurysm after endoscopic biliary stenting for bile duct cancer.
Watanabe M; Shiozawa K; Mimura T; Ito K; Kamata I; Kishimoto Y; Momiyama K; Igarashi Y; Sumino Y
World J Radiol; 2012 Mar; 4(3):115-20. PubMed ID: 22468193
[TBL] [Abstract][Full Text] [Related]
9. The Dramatic Haemostatic Effect of Covered Self-expandable Metallic Stents for Duodenal and Biliary Bleeding.
Sugimoto M; Takagi T; Suzuki R; Konno N; Asama H; Sato Y; Irie H; Nakamura J; Takasumi M; Hashimoto M; Kato T; Kobashi R; Hikichi T; Ohira H
Intern Med; 2021 Mar; 60(6):883-889. PubMed ID: 33087676
[TBL] [Abstract][Full Text] [Related]
10. Endoscopic side-by-side uncovered self-expandable metal stent placement for malignant hilar biliary obstruction.
Kitamura K; Yamamiya A; Ishii Y; Mitsui Y; Yoshida H
Ther Adv Gastrointest Endosc; 2019; 12():2631774519846345. PubMed ID: 31192317
[TBL] [Abstract][Full Text] [Related]
11. Early Covered Self-Expandable Metal Stent Placement Is Effective for Massive Post-endoscopic Sphincterotomy Bleeding.
Inoue T; Ibusuki M; Kitano R; Kobayashi Y; Ohashi T; Nakade Y; Sumida Y; Ito K; Yoneda M
Dig Dis Sci; 2020 Nov; 65(11):3324-3331. PubMed ID: 31950313
[TBL] [Abstract][Full Text] [Related]
12. Embolization for delayed arterial bleeding after percutaneous self-expandable metallic stent placement in patients with malignant biliary obstruction.
Kim PH; Kim JW; Gwon DI; Ko GY; Shin JH; Yoon HK
Br J Radiol; 2020 Apr; 93(1108):20190637. PubMed ID: 31778313
[TBL] [Abstract][Full Text] [Related]
13. Role of fully covered self-expandable metal stent for treatment of benign biliary strictures and bile leaks.
Pausawasadi N; Soontornmanokul T; Rerknimitr R
Korean J Radiol; 2012; 13 Suppl 1(Suppl 1):S67-73. PubMed ID: 22563290
[TBL] [Abstract][Full Text] [Related]
14. Lethal post-endoscopic retrograde cholangiopancreatography pancreatitis following fully covered metal stent placement in distal biliary obstruction due to unresectable cholangiocarcinoma.
Itoi T; Tsuchiya T; Tanaka R; Ikeuchi N; Sofuni A
Dig Endosc; 2013 May; 25 Suppl 2():117-21. PubMed ID: 23617661
[TBL] [Abstract][Full Text] [Related]
15. Hemobilia after bile duct resection: perforation of pseudoaneurysm into intra-pancreatic remnant bile duct: a case report.
Yoshida K; Umeda Y; Iwamuro M; Matsumoto K; Kato H; Uka M; Matsui Y; Yoshida R; Kuise T; Yasui K; Takagi K; Araki H; Yagi T; Fujiwara T
BMC Surg; 2020 Dec; 20(1):307. PubMed ID: 33261613
[TBL] [Abstract][Full Text] [Related]
16. Percutaneous transhepatic self-expanding metal stents for palliation of malignant biliary obstruction.
Lawson AJ; Beningfield SJ; Krige JE; Rischbieter P; Burmeister S
S Afr J Surg; 2012 Jul; 50(3):54, 56, 58 passim. PubMed ID: 22856436
[TBL] [Abstract][Full Text] [Related]
17. Biliary Self-Expandable Metal Stent Could Be Recommended as a First Treatment Modality for Immediate Refractory Post-Endoscopic Retrograde Cholangiopancreatography Bleeding.
Moon SY; Heo J; Jung MK; Cho CM
Clin Endosc; 2022 Jan; 55(1):128-135. PubMed ID: 34030429
[TBL] [Abstract][Full Text] [Related]
18. Temporary placement of a covered duodenal stent can avoid riskier anterograde biliary drainage when ERCP for obstructive jaundice fails due to duodenal invasion.
Goutorbe F; Rouquette O; Mulliez A; Scanzi J; Goutte M; Dapoigny M; Abergel A; Poincloux L
Surg Endosc; 2017 Feb; 31(2):625-631. PubMed ID: 27324333
[TBL] [Abstract][Full Text] [Related]
19. Emergency surgery for hemobilia due to hepatic artery pseudoaneurysm rupture complicated by Mirizzi syndrome type II: a case report.
Shishido Y; Fujimoto K; Yano Y; Mitsuoka E; Komatsubara T; Shio S; Ishii M; Higashiyama H
BMC Surg; 2021 Aug; 21(1):318. PubMed ID: 34353316
[TBL] [Abstract][Full Text] [Related]
20. Reintervention for occluded metal stent in malignant bile duct obstruction: A prospective randomized trial comparing covered and uncovered metal stent.
Lee BS; Ryu JK; Jang DK; Chung KH; Yoon WJ; Kim J; Woo SM; Lee SH; Lee WJ; Kim YT
J Gastroenterol Hepatol; 2016 Nov; 31(11):1901-1907. PubMed ID: 27029890
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]