171 related articles for article (PubMed ID: 35904510)
1. A universal, high-performance ECG signal processing engine to reduce clinical burden.
Gibbs A; Fitzpatrick M; Lilburn M; Easlea H; Francey J; Funston R; Diven J; Murray S; Mitchell OGJ; Condon A; Mitchell ARJ; Sanchez B; Steinhaus D
Ann Noninvasive Electrocardiol; 2022 Sep; 27(5):e12993. PubMed ID: 35904510
[TBL] [Abstract][Full Text] [Related]
2. Comparative study of a single lead ECG in a wearable device.
Funston R; Gibbs A; Diven J; Francey J; Easlea H; Murray S; Fitzpatrick M; Condon A; Mitchell ARJ
J Electrocardiol; 2022; 74():88-93. PubMed ID: 36055073
[TBL] [Abstract][Full Text] [Related]
3. QRS Detection Algorithm for Telehealth Electrocardiogram Recordings.
Khamis H; Weiss R; Xie Y; Chang CW; Lovell NH; Redmond SJ
IEEE Trans Biomed Eng; 2016 Jul; 63(7):1377-88. PubMed ID: 27046889
[TBL] [Abstract][Full Text] [Related]
4. Simple and Robust Realtime QRS Detection Algorithm Based on Spatiotemporal Characteristic of the QRS Complex.
Kim J; Shin H
PLoS One; 2016; 11(3):e0150144. PubMed ID: 26943949
[TBL] [Abstract][Full Text] [Related]
5. A lightweight QRS detector for single lead ECG signals using a max-min difference algorithm.
Pandit D; Zhang L; Liu C; Chattopadhyay S; Aslam N; Lim CP
Comput Methods Programs Biomed; 2017 Jun; 144():61-75. PubMed ID: 28495007
[TBL] [Abstract][Full Text] [Related]
6. Automatic digital ECG signal extraction and normal QRS recognition from real scene ECG images.
Wang S; Zhang S; Li Z; Huang L; Wei Z
Comput Methods Programs Biomed; 2020 Apr; 187():105254. PubMed ID: 31830698
[TBL] [Abstract][Full Text] [Related]
7. A robust ECG denoising technique using variable frequency complex demodulation.
Hossain MB; Bashar SK; Lazaro J; Reljin N; Noh Y; Chon KH
Comput Methods Programs Biomed; 2021 Mar; 200():105856. PubMed ID: 33309076
[TBL] [Abstract][Full Text] [Related]
8. QRS complex detection using stationary wavelet transform and adaptive thresholding.
Sharma N; Sunkaria RK; Sharma LD
Biomed Phys Eng Express; 2022 Sep; 8(6):. PubMed ID: 36049389
[No Abstract] [Full Text] [Related]
9. R-peaks detection based on stationary wavelet transform.
Merah M; Abdelmalik TA; Larbi BH
Comput Methods Programs Biomed; 2015 Oct; 121(3):149-60. PubMed ID: 26105724
[TBL] [Abstract][Full Text] [Related]
10. Optimal data fusion for the improvement of QRS complex detection in multi-channel ECG recordings.
Ledezma CA; Altuve M
Med Biol Eng Comput; 2019 Aug; 57(8):1673-1681. PubMed ID: 31098721
[TBL] [Abstract][Full Text] [Related]
11. Applicability of multiresolution wavelet analysis for QRS-waves detection.
Fedotov AA; Akulova AS; Akulov SA
Annu Int Conf IEEE Eng Med Biol Soc; 2016 Aug; 2016():3793-3796. PubMed ID: 28269112
[TBL] [Abstract][Full Text] [Related]
12. A wavelet-based ECG delineation algorithm for 32-bit integer online processing.
Di Marco LY; Chiari L
Biomed Eng Online; 2011 Apr; 10():23. PubMed ID: 21457580
[TBL] [Abstract][Full Text] [Related]
13. A method to extract realistic artifacts from electrocardiogram recordings for robust algorithm testing.
Galeotti L; Scully CG
J Electrocardiol; 2018; 51(6S):S56-S60. PubMed ID: 30180996
[TBL] [Abstract][Full Text] [Related]
14. A Stochastic Resonance Electrocardiogram Enhancement Algorithm for Robust QRS Detection.
Gungor CB; Mercier PP; Toreyin H
IEEE J Biomed Health Inform; 2022 Aug; 26(8):3743-3754. PubMed ID: 35617182
[TBL] [Abstract][Full Text] [Related]
15. A Real Time QRS Detection Algorithm Based on ET and PD Controlled Threshold Strategy.
Chen A; Zhang Y; Zhang M; Liu W; Chang S; Wang H; He J; Huang Q
Sensors (Basel); 2020 Jul; 20(14):. PubMed ID: 32708473
[TBL] [Abstract][Full Text] [Related]
16. QRS detection based on wavelet coefficients.
Zidelmal Z; Amirou A; Adnane M; Belouchrani A
Comput Methods Programs Biomed; 2012 Sep; 107(3):490-6. PubMed ID: 22296976
[TBL] [Abstract][Full Text] [Related]
17. Single-lead noninvasive fetal ECG extraction by means of combining clustering and principal components analysis.
Zhang Y; Yu S
Med Biol Eng Comput; 2020 Feb; 58(2):419-432. PubMed ID: 31858419
[TBL] [Abstract][Full Text] [Related]
18. Aiding the Detection of QRS Complex in ECG Signals by Detecting S Peaks Independently.
Sabherwal P; Singh L; Agrawal M
Cardiovasc Eng Technol; 2018 Sep; 9(3):469-481. PubMed ID: 29603061
[TBL] [Abstract][Full Text] [Related]
19. Online digital filter and QRS detector applicable in low resource ECG monitoring systems.
Tabakov S; Iliev I; Krasteva V
Ann Biomed Eng; 2008 Nov; 36(11):1805-15. PubMed ID: 18752068
[TBL] [Abstract][Full Text] [Related]
20. An innovative method based on Shannon energy envelope and summit navigation for detecting R peaks of noise stress test signals.
Van Manh H; Nguyen NV; Thang PM
J Electrocardiol; 2021; 65():8-17. PubMed ID: 33460861
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]