These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
22. Thermally actuated tapping mode atomic force microscopy with polymer microcantilevers. Mitra B; Gaitas A Rev Sci Instrum; 2009 Feb; 80(2):023703. PubMed ID: 19256649 [TBL] [Abstract][Full Text] [Related]
23. Control of tip-to-sample distance in atomic force microscopy: a dual-actuator tip-motion control scheme. Jeong Y; Jayanth GR; Menq CH Rev Sci Instrum; 2007 Sep; 78(9):093706. PubMed ID: 17902954 [TBL] [Abstract][Full Text] [Related]
24. Atomic force microscopy with a 12-electrode piezoelectric tube scanner. Yong YK; Ahmed B; Moheimani SO Rev Sci Instrum; 2010 Mar; 81(3):033701. PubMed ID: 20370179 [TBL] [Abstract][Full Text] [Related]
25. Parametric noise squeezing and parametric resonance of microcantilevers in air and liquid environments. Prakash G; Raman A; Rhoads J; Reifenberger RG Rev Sci Instrum; 2012 Jun; 83(6):065109. PubMed ID: 22755664 [TBL] [Abstract][Full Text] [Related]
26. High-speed dynamic atomic force microscopy by using a Q-controlled cantilever eigenmode as an actuator. Balantekin M Ultramicroscopy; 2015 Feb; 149():45-50. PubMed ID: 25436928 [TBL] [Abstract][Full Text] [Related]
27. Effectiveness of Modal Decomposition for Tapping Atomic Force Microscopy Microcantilevers in Liquid Environment. Kim IK; Lee SI J Nanosci Nanotechnol; 2016 May; 16(5):4362-9. PubMed ID: 27483758 [TBL] [Abstract][Full Text] [Related]
28. Tuneable Q-Factor of MEMS Cantilevers with Integrated Piezoelectric Thin Films. Fischeneder M; Oposich M; Schneider M; Schmid U Sensors (Basel); 2018 Nov; 18(11):. PubMed ID: 30423949 [TBL] [Abstract][Full Text] [Related]
29. Calibration of the spring constant of AFM cantilever. Jing GY; Ma J; Yu DP J Electron Microsc (Tokyo); 2007 Jan; 56(1):21-5. PubMed ID: 17303619 [TBL] [Abstract][Full Text] [Related]
30. Metasurface-enhanced optical lever sensitivity for atomic force microscopy. Yao Z; Xia X; Hou Y; Zhang P; Zhai X; Chen Y Nanotechnology; 2019 Sep; 30(36):365501. PubMed ID: 31121576 [TBL] [Abstract][Full Text] [Related]
31. Calibration of lateral force measurements in atomic force microscopy with a piezoresistive force sensor. Xie H; Vitard J; Haliyo S; Régnier S; Boukallel M Rev Sci Instrum; 2008 Mar; 79(3):033708. PubMed ID: 18377016 [TBL] [Abstract][Full Text] [Related]
32. Active Damping of a Piezoelectric Tube Scanner using Self-Sensing Piezo Actuation. Kuiper S; Schitter G Mechatronics (Oxf); 2010 Sep; 20(6):656-665. PubMed ID: 26412944 [TBL] [Abstract][Full Text] [Related]
33. Use of self-actuating and self-sensing cantilevers for imaging biological samples in fluid. Fantner GE; Schumann W; Barbero RJ; Deutschinger A; Todorov V; Gray DS; Belcher AM; Rangelow IW; Youcef-Toumi K Nanotechnology; 2009 Oct; 20(43):434003. PubMed ID: 19801750 [TBL] [Abstract][Full Text] [Related]
35. Study of sensitivity and noise in the piezoelectric self-sensing and self-actuating cantilever with an integrated Wheatstone bridge circuit. Shin C; Jeon I; Khim ZG; Hong JW; Nam H Rev Sci Instrum; 2010 Mar; 81(3):035109. PubMed ID: 20370215 [TBL] [Abstract][Full Text] [Related]
36. Analysis the effect of different geometries of AFM's cantilever on the dynamic behavior and the critical forces of three-dimensional manipulation. Korayem MH; Saraie MB; Saraee MB Ultramicroscopy; 2017 Apr; 175():9-24. PubMed ID: 28110179 [TBL] [Abstract][Full Text] [Related]
37. Force Spectroscopy with 9-μs Resolution and Sub-pN Stability by Tailoring AFM Cantilever Geometry. Edwards DT; Faulk JK; LeBlanc MA; Perkins TT Biophys J; 2017 Dec; 113(12):2595-2600. PubMed ID: 29132641 [TBL] [Abstract][Full Text] [Related]
38. Influence of Poisson's ratio variation on lateral spring constant of atomic force microscopy cantilevers. Yeh MK; Tai NH; Chen BY Ultramicroscopy; 2008 Sep; 108(10):1025-9. PubMed ID: 18547729 [TBL] [Abstract][Full Text] [Related]