BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

180 related articles for article (PubMed ID: 35922799)

  • 1. Biomechanical study on fixation methods for horizontal oblique metacarpal shaft fractures.
    Chiu YC; Hsu CE; Ho TY; Ting YN; Tsai MT; Hsu JT
    J Orthop Surg Res; 2022 Aug; 17(1):374. PubMed ID: 35922799
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Comparison of the fixation ability between lag screw and bone plate for oblique metacarpal shaft fracture.
    Chiu YC; Ho TY; Hsu CE; Ting YN; Tsai MT; Hsu JT
    J Orthop Surg Res; 2022 Feb; 17(1):72. PubMed ID: 35123532
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Bone plate fixation ability on the dorsal and lateral sides of a metacarpal shaft transverse fracture.
    Chiu YC; Hsu CE; Ho TY; Ting YN; Tsai MT; Hsu JT
    J Orthop Surg Res; 2021 Jul; 16(1):441. PubMed ID: 34233702
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Effect of oblique headless compression screw fixation for metacarpal shaft fracture: a biomechanical in vitro study.
    Chiu YC; Ho TY; Ting YN; Tsai MT; Huang HL; Hsu CE; Hsu JT
    BMC Musculoskelet Disord; 2021 Feb; 22(1):146. PubMed ID: 33546670
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Comparison of Dorsal Plate Fixation Versus Intramedullary Headless Screw Fixation of Unstable Metacarpal Shaft Fractures: A Biomechanical Study.
    Melamed E; Hinds RM; Gottschalk MB; Kennedy OD; Capo JT
    Hand (N Y); 2016 Dec; 11(4):421-426. PubMed ID: 28149208
    [No Abstract]   [Full Text] [Related]  

  • 6. Biomechanical analysis of locking plates for fixation of metacarpal shaft fractures: A finite element analysis.
    Zhang JF; Li Y; Huo YX; Yan M; Liang SL; Wang L; Wang BC
    Orthop Traumatol Surg Res; 2022 Dec; 108(8):103340. PubMed ID: 35643362
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Biomechanical analysis of plate versus K-wire fixation for metacarpal shaft fractures with wedge-shaped bone defects.
    Chiu YC; Ho TY; Hsu CE; Yeh CW; Ting YN; Tsai MT; Hsu JT
    BMC Musculoskelet Disord; 2024 May; 25(1):350. PubMed ID: 38702748
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Comparison between locking and non-locking plates for fixation of metacarpal fractures in an animal model.
    Ochman S; Doht S; Paletta J; Langer M; Raschke MJ; Meffert RH
    J Hand Surg Am; 2010 Apr; 35(4):597-603. PubMed ID: 20299161
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Metacarpal shaft fixation: a biomechanical comparison of dorsal plating, lag screws, and headless compression screws.
    Dyrna FGE; Avery DM; Yoshida R; Lam D; Oeckenpöhler S; Cote MP; Obopilwe E; Rodner CM; Mazzocca AD
    BMC Musculoskelet Disord; 2021 Apr; 22(1):335. PubMed ID: 33827523
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Comparing biomechanical strength of unicortical locking plate versus bicortical compression plate for transverse midshaft metacarpal fracture.
    Shanmugam R; Jian CYCCS; Haseeb A; Aik S
    J Orthop Surg (Hong Kong); 2018; 26(3):2309499018802511. PubMed ID: 30270746
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Comparison of the fixation ability of headless compression screws and locking plate for metacarpal shaft transverse fracture.
    Chiu YC; Hsu CE; Ho TY; Ting YN; Wei BH; Tsai MT; Hsu JT
    Medicine (Baltimore); 2021 Oct; 100(39):e27375. PubMed ID: 34596154
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Biomechanical study of the fixation ability of the dorsal and volar locking plate for transverse metacarpal neck fractures.
    Ho TY; Hsu CE; Wang WC; Ting YN; Tsai MT; Chiu YC; Hsu JT
    Medicine (Baltimore); 2023 Sep; 102(36):e34981. PubMed ID: 37682204
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Comparison of treatment of oblique and spiral metacarpal and phalangeal fractures with mini plate plus screw or screw only.
    Başar H; Başar B; Başçı O; Topkar OM; Erol B; Tetik C
    Arch Orthop Trauma Surg; 2015 Apr; 135(4):499-504. PubMed ID: 25682110
    [TBL] [Abstract][Full Text] [Related]  

  • 14. New fixation approach for transverse metacarpal neck fracture: a biomechanical study.
    Chiu YC; Tsai MT; Hsu CE; Hsu HC; Huang HL; Hsu JT
    J Orthop Surg Res; 2018 Jul; 13(1):183. PubMed ID: 30045774
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Higher stability with locking plates in hand surgery? Biomechanical investigation of the TriLock system in a fracture model.
    Doht S; Jansen H; Meffert R; Frey S
    Int Orthop; 2012 Aug; 36(8):1641-6. PubMed ID: 22426933
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Fixation of Metacarpal Shaft Fractures: Biomechanical Comparison of Intramedullary Nail Crossed K-Wires and Plate-Screw Constructs.
    Curtis BD; Fajolu O; Ruff ME; Litsky AS
    Orthop Surg; 2015 Aug; 7(3):256-60. PubMed ID: 26311101
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Unicortical PEEK inset locking fixation for metacarpal fractures: a biomechanical study.
    Mudrick CA; Owen JR; Wayne JS; Isaacs JE
    Eur J Orthop Surg Traumatol; 2014 Dec; 24(8):1415-20. PubMed ID: 24121825
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Three-screw versus two-screw fixation of distal fragment in fifth metacarpal neck fractures stabilized with locking plate.
    Zhu H; Bao B; Zheng X
    Sci Rep; 2017 Oct; 7(1):12516. PubMed ID: 28970518
    [TBL] [Abstract][Full Text] [Related]  

  • 19. A Comparative Study of Tensile Strength of Three Operative Fixation Techniques for Metacarpal Shaft Fractures in Adults: A Cadaver Study.
    Oh JR; Kim DS; Yeom JS; Kang SK; Kim YT
    Clin Orthop Surg; 2019 Mar; 11(1):120-125. PubMed ID: 30838116
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Effect of a figure-of-eight cerclage wire with two Kirschner wires on fixation strength for transverse metacarpal shaft fractures: an in vitro study with artificial bone.
    Chiu YC; Hsu CE; Ho TY; Ting YN; Tsai MT; Hsu JT
    BMC Musculoskelet Disord; 2021 May; 22(1):431. PubMed ID: 33971840
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.