182 related articles for article (PubMed ID: 35926920)
1. Impact of Commissural Misalignment on Hydrodynamic Function Following Valve-in-Valve Intervention With the ACURATE neo.
Meier D; Akodad M; Chatfield AG; Lutter G; Puehler T; Søndergaard L; Wood DA; Webb JG; Sellers SL; Sathananthan J
JACC Cardiovasc Interv; 2022 Aug; 15(15):1532-1539. PubMed ID: 35926920
[TBL] [Abstract][Full Text] [Related]
2. Impact of implant depth on hydrodynamic function with the ACURATE
Sathananthan J; Sellers SL; Fraser R; Dvir D; Hensey M; Murdoch DJ; Blanke P; Pibarot P; Toggweiler S; Wood D; Leipsic J; Webb JG
EuroIntervention; 2019 May; 15(1):78-87. PubMed ID: 30479308
[TBL] [Abstract][Full Text] [Related]
3. Valve-in-Valve Transcatheter Aortic Valve Replacement and Bioprosthetic Valve Fracture Comparing Different Transcatheter Heart Valve Designs: An Ex Vivo Bench Study.
Sathananthan J; Sellers S; Barlow AM; Stanová V; Fraser R; Toggweiler S; Allen KB; Chhatriwalla A; Murdoch DJ; Hensey M; Lau K; Alkhodair A; Dvir D; Asgar AW; Cheung A; Blanke P; Ye J; Rieu R; Pibarot P; Wood D; Leipsic J; Webb JG
JACC Cardiovasc Interv; 2019 Jan; 12(1):65-75. PubMed ID: 30621980
[TBL] [Abstract][Full Text] [Related]
4. Coronary Access After Transcatheter Aortic Valve Replacement With Commissural Alignment: The ALIGN-ACCESS Study.
Tarantini G; Nai Fovino L; Scotti A; Massussi M; Cardaioli F; Rodinò G; Benedetti A; Boiago M; Matsuda Y; Continisio S; Montonati C; Cacciavillani L; Pavei A; Masiero G; Napodano M; Fraccaro C; Fabris T; Iliceto S
Circ Cardiovasc Interv; 2022 Feb; 15(2):e011045. PubMed ID: 35167332
[TBL] [Abstract][Full Text] [Related]
5. Patient-Specific Implantation Technique to Obtain Neo-Commissural Alignment With Self-Expanding Transcatheter Aortic Valves.
Bieliauskas G; Wong I; Bajoras V; Wang X; Kofoed KF; De Backer O; Søndergaard L
JACC Cardiovasc Interv; 2021 Oct; 14(19):2097-2108. PubMed ID: 34538602
[TBL] [Abstract][Full Text] [Related]
6. Acurate Neo Implantation to Treat Degenerative Regurgitation of Surgical Bioprostheses.
Arunothayaraj S; Williams T; Cockburn J; Hildick-Smith D
Cardiovasc Revasc Med; 2021 Jul; 28S():105-108. PubMed ID: 32981854
[TBL] [Abstract][Full Text] [Related]
7. A bench test study of bioprosthetic valve fracture performed before versus after transcatheter valve-in-valve intervention.
Sathananthan J; Fraser R; Hatoum H; Barlow AM; Stanová V; Allen KB; Chhatriwalla AK; Rieu R; Pibarot P; Dasi LP; Søndergaard L; Wood DA; Webb JG
EuroIntervention; 2020 Mar; 15(16):1409-1416. PubMed ID: 31854302
[TBL] [Abstract][Full Text] [Related]
8. Commissural Alignment of Bioprosthetic Aortic Valve and Native Aortic Valve Following Surgical and Transcatheter Aortic Valve Replacement and its Impact on Valvular Function and Coronary Filling.
Fuchs A; Kofoed KF; Yoon SH; Schaffner Y; Bieliauskas G; Thyregod HG; Makkar R; Søndergaard L; De Backer O; Bapat V
JACC Cardiovasc Interv; 2018 Sep; 11(17):1733-1743. PubMed ID: 30121280
[TBL] [Abstract][Full Text] [Related]
9. Implications of hydrodynamic testing to guide sizing of self-expanding transcatheter heart valves for valve-in-valve procedures.
Sathananthan J; Hensey M; Fraser R; Landes U; Blanke P; Hatoum H; Dasi LP; Sedaghat A; Bapat VN; Leipsic J; Søndergaard L; Wood DA; Webb JG
Catheter Cardiovasc Interv; 2020 Sep; 96(3):E332-E340. PubMed ID: 31647178
[TBL] [Abstract][Full Text] [Related]
10. Timing of bioprosthetic valve fracture in transcatheter valve-in-valve intervention: impact on valve durability and leaflet integrity.
Meier D; Payne GW; Mostaço-Guidolin LB; Bouchareb R; Rich C; Lai A; Chatfield AG; Akodad M; Salcudean H; Lutter G; Puehler T; Pibarot P; Allen KB; Chhatriwalla AK; Sondergaard L; Wood DA; Webb JG; Leipsic JA; Sathananthan J; Sellers SL
EuroIntervention; 2023 Feb; 18(14):1165-1177. PubMed ID: 36534495
[TBL] [Abstract][Full Text] [Related]
11. Transcatheter aortic valve replacement with the self-expanding ACURATE Neo2 in patients with horizontal aorta: Insights from the ITAL-neo registry.
Barki M; Ielasi A; Buono A; Maffeo D; Montonati C; Pellegrini D; Pellicano M; Gorla R; Costa G; Cozzi O; Ancona M; Soriano F; De Carlo M; Ferrara E; Giannini F; Massussi M; Fovino LN; Messina A; Sgroi C; Gallo F; Nerla R; Saccocci M; D'Ascenzo F; Conrotto F; Bettari L; Fiorina C; Castriota F; Poli A; Petronio AS; Oreglia J; Montorfano M; Regazzoli D; Reimers B; Barbanti M; Tamburino C; Bedogni F; Tarantini G; Tespili M
Int J Cardiol; 2023 Oct; 389():131236. PubMed ID: 37532153
[TBL] [Abstract][Full Text] [Related]
12. Repeat transcatheter aortic valve implantation and implications for transcatheter heart valve performance: insights from bench testing.
Sathananthan J; Fraser R; Landes U; Rich C; Sellers SL; Leipsic J; Blanke P; Lutter G; Frank D; Puehler T; Wood DA; Søndergaard L; Webb JG
EuroIntervention; 2021 Nov; 17(10):856-864. PubMed ID: 33495142
[TBL] [Abstract][Full Text] [Related]
13. Comparison of Self-Expanding Bioprostheses for Transcatheter Aortic Valve Replacement in Patients With Symptomatic Severe Aortic Stenosis: SCOPE 2 Randomized Clinical Trial.
Tamburino C; Bleiziffer S; Thiele H; Scholtz S; Hildick-Smith D; Cunnington M; Wolf A; Barbanti M; Tchetchè D; Garot P; Pagnotta P; Gilard M; Bedogni F; Van Belle E; Vasa-Nicotera M; Chieffo A; Deutsch O; Kempfert J; Søndergaard L; Butter C; Trillo-Nouche R; Lotfi S; Möllmann H; Joner M; Abdel-Wahab M; Bogaerts K; Hengstenberg C; Capodanno D
Circulation; 2020 Dec; 142(25):2431-2442. PubMed ID: 33054367
[TBL] [Abstract][Full Text] [Related]
14. Transcatheter Aortic Valve Replacement With Self-Expanding ACURATE neo2: Postprocedural Hemodynamic and Short-Term Clinical Outcomes.
Buono A; Gorla R; Ielasi A; Costa G; Cozzi O; Ancona M; Soriano F; De Carlo M; Ferrara E; Giannini F; Massussi M; Fovino LN; Pero G; Bettari L; Acerbi E; Messina A; Sgroi C; Pellicano M; Sun J; Gallo F; Franchina AG; Bruno F; Nerla R; Saccocci M; Villa E; D'Ascenzo F; Conrotto F; Cuccia C; Tarantini G; Fiorina C; Castriota F; Poli A; Petronio AS; Oreglia J; Montorfano M; Regazzoli D; Reimers B; Tamburino C; Tespili M; Bedogni F; Barbanti M; Maffeo D;
JACC Cardiovasc Interv; 2022 Jun; 15(11):1101-1110. PubMed ID: 35595675
[TBL] [Abstract][Full Text] [Related]
15. Neosinus and Sinus Flow After Self-Expanding and Balloon-Expandable Transcatheter Aortic Valve Replacement.
Hatoum H; Gooden SCM; Sathananthan J; Sellers S; Kutting M; Marx P; Lilly SM; Ihdayhid AR; Thourani VH; Dasi LP
JACC Cardiovasc Interv; 2021 Dec; 14(24):2657-2666. PubMed ID: 34838462
[TBL] [Abstract][Full Text] [Related]
16. Bioprosthetic Valve Remodeling in Nonfracturable Surgical Valves: Impact on THV Expansion and Hydrodynamic Performance.
Meier D; Puehler T; Lutter G; Shen C; Lai A; Gill H; Akodad M; Tzimas G; Chhatriwalla A; Allen KB; Blanke P; Payne GW; Wood DA; Leipsic JA; Webb JG; Sellers SL; Sathananthan J
JACC Cardiovasc Interv; 2023 Jul; 16(13):1594-1608. PubMed ID: 37294230
[TBL] [Abstract][Full Text] [Related]
17. Fracture of small Mitroflow® aortic bioprosthesis following valve-in-valve transcatheter aortic valve replacement with ACURATE neo valve-From bench testing to clinical practice.
Amat-Santos IJ; Gutiérrez H; Sathananthan J; Webb JG
Catheter Cardiovasc Interv; 2020 Mar; 95(4):E120-E122. PubMed ID: 31140682
[TBL] [Abstract][Full Text] [Related]
18. Transcatheter aortic valve implantation in patients with a small aortic annulus: performance of supra-, intra- and infra-annular transcatheter heart valves.
Voigtländer L; Kim WK; Mauri V; Goßling A; Renker M; Sugiura A; Linder M; Schmidt T; Schofer N; Westermann D; Reichenspurner H; Nickenig G; Blankenberg S; Hamm C; Conradi L; Adam M; Sinning JM; Seiffert M
Clin Res Cardiol; 2021 Dec; 110(12):1957-1966. PubMed ID: 34387736
[TBL] [Abstract][Full Text] [Related]
19. Alignment of Transcatheter Aortic-Valve Neo-Commissures (ALIGN TAVR): Impact on Final Valve Orientation and Coronary Artery Overlap.
Tang GHL; Zaid S; Fuchs A; Yamabe T; Yazdchi F; Gupta E; Ahmad H; Kofoed KF; Goldberg JB; Undemir C; Kaple RK; Shah PB; Kaneko T; Lansman SL; Khera S; Kovacic JC; Dangas GD; Lerakis S; Sharma SK; Kini A; Adams DH; Khalique OK; Hahn RT; Søndergaard L; George I; Kodali SK; De Backer O; Leon MB; Bapat VN
JACC Cardiovasc Interv; 2020 May; 13(9):1030-1042. PubMed ID: 32192985
[TBL] [Abstract][Full Text] [Related]
20. Early Acurate Neo transcatheter heart valve degeneration in a haemodialysis patient successfully managed with Sapien 3 Ultra: a case report.
Savvoulidis P; Nadir A; Ludman PF; Doshi SN
Eur Heart J Case Rep; 2022 Jul; 6(7):ytac279. PubMed ID: 35854896
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]