172 related articles for article (PubMed ID: 35933738)
1. Fluorescence ratiometric assay for discriminating GSH and Cys based on the composites of UiO-66-NH
Ma J; Lu Z; Li C; Luo Y; Shi YE; Alam P; Lam JWY; Wang Z; Tang BZ
Biosens Bioelectron; 2022 Nov; 215():114582. PubMed ID: 35933738
[TBL] [Abstract][Full Text] [Related]
2. Dual-emissive europium doped UiO-66-based ratiometric light-up biosensor for highly sensitive detection of histidinemia biomarker.
Li L; Zhang LL; Zou J; Zou J; Duan LY; Gao Y; Peng G; Huang X; Lu L
Anal Chim Acta; 2024 Feb; 1290():342202. PubMed ID: 38246745
[TBL] [Abstract][Full Text] [Related]
3. One-pot synthesis of enhanced fluorescent copper nanoclusters encapsulated in metal-organic frameworks.
Han B; Hu X; Yu M; Peng T; Li Y; He G
RSC Adv; 2018 Jun; 8(40):22748-22754. PubMed ID: 35539698
[TBL] [Abstract][Full Text] [Related]
4. Silver nanoparticles combined with amino-functionalized UiO-66 for sensitive detection of glutathione.
Huo P; Li Z; Gong C; Yao R; Fan C; Chen Z; Pu S
Spectrochim Acta A Mol Biomol Spectrosc; 2022 Feb; 267(Pt 2):120617. PubMed ID: 34802928
[TBL] [Abstract][Full Text] [Related]
5. UiO-66-NH
Wang N; Xie M; Wang M; Li Z; Su X
Talanta; 2020 Dec; 220():121352. PubMed ID: 32928390
[TBL] [Abstract][Full Text] [Related]
6. UiO-66-NH
Lei Y; Gao N; Huang P; Wu FY
Anal Chim Acta; 2024 Apr; 1299():342421. PubMed ID: 38499417
[TBL] [Abstract][Full Text] [Related]
7. One-pot synthesis of copper nanocluster/Tb-MOF composites for the ratiometric fluorescence detection of Cu
Liu P; Hao R; Sun W; Lin Z; Jing T
Luminescence; 2022 Oct; 37(10):1793-1799. PubMed ID: 35946061
[TBL] [Abstract][Full Text] [Related]
8. Turn-on fluorescence detection of cysteine with glutathione protected silver nanoclusters.
Cao N; Zhou H; Tan H; Qi R; Chen J; Zhang S; Xu J
Methods Appl Fluoresc; 2019 Jun; 7(3):034004. PubMed ID: 31174198
[TBL] [Abstract][Full Text] [Related]
9. High-sensitivity Detection of Cysteine and Glutathione Using Au Nanoclusters Based on Aggregation-induced Emission.
Zhang Y; Xu H; Chen Y; You X; Pu Y; Xu W; Liao X
J Fluoresc; 2020 Dec; 30(6):1491-1498. PubMed ID: 32897494
[TBL] [Abstract][Full Text] [Related]
10. Dual-ligand lanthanide metal-organic framework for ratiometric fluorescence detection of the anthrax biomarker dipicolinic acid.
Huo P; Li Z; Yao R; Deng Y; Gong C; Zhang D; Fan C; Pu S
Spectrochim Acta A Mol Biomol Spectrosc; 2022 Dec; 282():121700. PubMed ID: 35933778
[TBL] [Abstract][Full Text] [Related]
11. Photoluminescence light-up detection of zinc ion and imaging in living cells based on the aggregation induced emission enhancement of glutathione-capped copper nanoclusters.
Lin L; Hu Y; Zhang L; Huang Y; Zhao S
Biosens Bioelectron; 2017 Aug; 94():523-529. PubMed ID: 28343105
[TBL] [Abstract][Full Text] [Related]
12. Ratiometric fluorescent detection of exosomal piRNA-823 based on Au NCs/UiO-66-NH
Tong Y; Guan B; Sun Z; Dong X; Chen Y; Li Y; Jiang Y; Li J
Talanta; 2023 May; 257():124307. PubMed ID: 36764170
[TBL] [Abstract][Full Text] [Related]
13. Dual-emitting metal-organic frameworks for ratiometric fluorescence detection of fluoride and Al
Zhang M; Liang R; Li K; Chen T; Li S; Zhang Y; Zhang D; Chen X
Spectrochim Acta A Mol Biomol Spectrosc; 2022 Apr; 271():120896. PubMed ID: 35121473
[TBL] [Abstract][Full Text] [Related]
14. Dual-emissive EY/UiO-66-NH
Yu F; Wang Y; Liu T; Liu X; Jiang H; Wang X
Analyst; 2022 Aug; 147(17):3867-3875. PubMed ID: 35920663
[TBL] [Abstract][Full Text] [Related]
15. Chemical etching of pH-sensitive aggregation-induced emission-active gold nanoclusters for ultra-sensitive detection of cysteine.
Wang J; Lin X; Su L; Yin J; Shu T; Zhang X
Nanoscale; 2018 Dec; 11(1):294-300. PubMed ID: 30534733
[TBL] [Abstract][Full Text] [Related]
16. Aggregation-caused dual-signal response of gold nanoclusters for ratiometric optical detection of cysteine.
Hong LN; Cao HT; Feng YX; Guo LZ; Liu MQ; Zhang K; Mai X; Li N
Anal Sci; 2023 Oct; 39(10):1719-1726. PubMed ID: 37405629
[TBL] [Abstract][Full Text] [Related]
17. A label-free turn-on-off fluorescent sensor for the sensitive detection of cysteine via blocking the Ag
Li Y; Deng Y; Zhou X; Hu J
Talanta; 2018 Mar; 179():742-752. PubMed ID: 29310302
[TBL] [Abstract][Full Text] [Related]
18. Embedding carbon dots and gold nanoclusters in metal-organic frameworks for ratiometric fluorescence detection of Cu
Tan Q; Zhang R; Zhang G; Liu X; Qu F; Lu L
Anal Bioanal Chem; 2020 Feb; 412(6):1317-1324. PubMed ID: 31927600
[TBL] [Abstract][Full Text] [Related]
19. A highly selective sensor of cysteine with tunable sensitivity and detection window based on dual-emission Ag nanoclusters.
Zhu J; Song X; Gao L; Li Z; Liu Z; Ding S; Zou S; He Y
Biosens Bioelectron; 2014 Mar; 53():71-5. PubMed ID: 24121225
[TBL] [Abstract][Full Text] [Related]
20. A target-responsive release SERS sensor for sensitive detection of tetracycline using aptamer-gated HP-UiO-66-NH
Li H; Geng W; Haruna SA; Hassan MM; Chen Q
Anal Chim Acta; 2022 Aug; 1220():339999. PubMed ID: 35868696
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]