These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

334 related articles for article (PubMed ID: 35934573)

  • 21. Feasibility study and material selection for powder-bed fusion process in printing of denture clasps.
    Ma K; Chen H; Shen Y; Guo Y; Li W; Wang Y; Zhang Y; Sun Y
    Comput Biol Med; 2023 May; 157():106772. PubMed ID: 36963354
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Laser surface modification of Ti--6Al--4V: wear and corrosion characterization in simulated biofluid.
    Singh R; Kurella A; Dahotre NB
    J Biomater Appl; 2006 Jul; 21(1):49-73. PubMed ID: 16443617
    [TBL] [Abstract][Full Text] [Related]  

  • 23. A comparison of corrosion resistance of cobalt-chromium-molybdenum metal ceramic alloy fabricated with selective laser melting and traditional processing.
    Zeng L; Xiang N; Wei B
    J Prosthet Dent; 2014 Nov; 112(5):1217-24. PubMed ID: 24836284
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Effects of tetrabutylammonium dihydrogen trifluoride etchant on bond strengths of resin composites with Ti-6Al-4V and Co-Cr alloys.
    Kamada K; Taira Y; Egoshi T; Kaida K
    J Oral Sci; 2023 Jul; 65(3):153-157. PubMed ID: 37258232
    [TBL] [Abstract][Full Text] [Related]  

  • 25. An initial study of diffusion bonds between superplastic Ti-6Al-4V for implant dentistry applications.
    Elias KL; Daehn GS; Brantley WA; McGlumphy EA
    J Prosthet Dent; 2007 Jun; 97(6):357-65. PubMed ID: 17618918
    [TBL] [Abstract][Full Text] [Related]  

  • 26. [Corrosion resistance of a new Ti-12.5Zr-3Nb-2.5Sn alloy].
    Hu X; Wei Q; Li CY; Deng JY; Liu S; Zhang LY
    Zhonghua Kou Qiang Yi Xue Za Zhi; 2010 Sep; 45(9):569-72. PubMed ID: 21122455
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Corrosion behavior of cast Ti-6Al-4V alloyed with Cu.
    Koike M; Cai Z; Oda Y; Hattori M; Fujii H; Okabe T
    J Biomed Mater Res B Appl Biomater; 2005 May; 73(2):368-74. PubMed ID: 15744719
    [TBL] [Abstract][Full Text] [Related]  

  • 28. In-situ monitoring of the electrochemical behavior of cellular structured biomedical Ti-6Al-4V alloy fabricated by electron beam melting in simulated physiological fluid.
    Gai X; Bai Y; Li S; Hou W; Hao Y; Zhang X; Yang R; Misra RDK
    Acta Biomater; 2020 Apr; 106():387-395. PubMed ID: 32058079
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Effects of dextrose and lipopolysaccharide on the corrosion behavior of a Ti-6Al-4V alloy with a smooth surface or treated with double-acid-etching.
    Faverani LP; Assunção WG; de Carvalho PS; Yuan JC; Sukotjo C; Mathew MT; Barao VA
    PLoS One; 2014; 9(3):e93377. PubMed ID: 24671257
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Effect of porcelain firing and cementation on the marginal fit of implant-supported metal-ceramic restorations fabricated by additive or subtractive manufacturing methods.
    Yildirim B
    J Prosthet Dent; 2020 Oct; 124(4):476.e1-476.e6. PubMed ID: 32451142
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Evaluation of surface characteristics of Ti-6Al-4V and Tilite alloys used for implant abutments.
    Lima EM; Silva WJ; Moura JS; Faot F; Del Bel Cury AA
    Braz Oral Res; 2006; 20(4):307-11. PubMed ID: 17242790
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Functionally graded Co-Cr-Mo coating on Ti-6Al-4V alloy structures.
    Vamsi Krishna B; Xue W; Bose S; Bandyopadhyay A
    Acta Biomater; 2008 May; 4(3):697-706. PubMed ID: 18054298
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Corrosion behavior of pure titanium and titanium alloys in fluoride-containing solutions.
    Nakagawa M; Matsuya S; Udoh K
    Dent Mater J; 2001 Dec; 20(4):305-14. PubMed ID: 11915624
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Understanding the effects of PBF process parameter interplay on Ti-6Al-4V surface properties.
    Majumdar T; Bazin T; Massahud Carvalho Ribeiro E; Frith JE; Birbilis N
    PLoS One; 2019; 14(8):e0221198. PubMed ID: 31465449
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Effect of manufacturing techniques on the marginal and internal fit of cobalt-chromium implant-supported multiunit frameworks.
    Akçin ET; Güncü MB; Aktaş G; Aslan Y
    J Prosthet Dent; 2018 Nov; 120(5):715-720. PubMed ID: 30017153
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Laser and plasma dental soldering techniques applied to Ti-6Al-4V alloy: ultimate tensile strength and finite element analysis.
    Castro MG; Araújo CA; Menegaz GL; Silva JP; Nóbilo MA; Simamoto Júnior PC
    J Prosthet Dent; 2015 May; 113(5):460-6. PubMed ID: 25749079
    [TBL] [Abstract][Full Text] [Related]  

  • 37. The effect of build orientation on the microstructure and properties of selective laser melting Ti-6Al-4V for removable partial denture clasps.
    Xie W; Zheng M; Wang J; Li X
    J Prosthet Dent; 2020 Jan; 123(1):163-172. PubMed ID: 30982620
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Biocompatibility of new low-cost (α + β)-type Ti-Mo-Fe alloys for long-term implantation.
    Abdelrhman Y; Gepreel MA; Kobayashi S; Okano S; Okamoto T
    Mater Sci Eng C Mater Biol Appl; 2019 Jun; 99():552-562. PubMed ID: 30889729
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Comparative analysis of the surface properties and corrosion resistance of Co-Cr dental alloys fabricated by different methods.
    Xing X; Hu Q; Liu Y; Wang Y; Cheng H
    J Prosthet Dent; 2022 Mar; 127(3):497.e1-497.e11. PubMed ID: 34998583
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Scanning Electron Microscopy Analysis of the Adaptation of Single-Unit Screw-Retained Computer-Aided Design/Computer-Aided Manufacture Abutments After Mechanical Cycling.
    Markarian RA; Galles DP; Gomes França FM
    Int J Oral Maxillofac Implants; 2018; 33(1):127–136. PubMed ID: 28632256
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 17.