141 related articles for article (PubMed ID: 35941283)
1. Complications related to the Cook-Swartz implantable Doppler probe use in head and neck microvascular reconstruction: a systematic review.
Chiesa-Estomba CM; González-García JA; Genden EM; Piazza C; Guntinas-Lichius O; Vander-Poorten V; Kowalski LP; López F; Quer M; Rodrigo JP; Sanabria Á; Fernández-Álvarez V; Suárez C; Cohen O; de Bree R; Shaha AR; Mäkitie AA; Ferlito A
Eur Arch Otorhinolaryngol; 2023 Jan; 280(1):23-37. PubMed ID: 35941283
[TBL] [Abstract][Full Text] [Related]
2. Rationale for the use of the implantable Doppler probe based on 7 years' experience.
Ho MW; Cassidy C; Brown JS; Shaw RJ; Bekiroglu F; Rogers SN
Br J Oral Maxillofac Surg; 2014 Jul; 52(6):530-4. PubMed ID: 24721166
[TBL] [Abstract][Full Text] [Related]
3. Direct comparison of postoperative monitoring of free flaps with microdialysis, implantable cook-swartz Doppler probe, and clinical monitoring in 20 consecutive patients.
Frost MW; Niumsawatt V; Rozen WM; Eschen GE; Damsgaard TE; Kiil BJ
Microsurgery; 2015 May; 35(4):262-71. PubMed ID: 25285732
[TBL] [Abstract][Full Text] [Related]
4. Implantable Cook-Swartz Doppler probe versus Synovis Flow Coupler for the post-operative monitoring of free flap breast reconstruction.
Um GT; Chang J; Louie O; Colohan SM; Said HK; Neligan PC; Mathes DW
J Plast Reconstr Aesthet Surg; 2014 Jul; 67(7):960-6. PubMed ID: 24767693
[TBL] [Abstract][Full Text] [Related]
5. The efficacy of the Cook-Swartz implantable Doppler in the detection of free-flap compromise: a systematic review protocol.
Agha RA; Gundogan B; Fowler AJ; Bragg TW; Orgill DP
BMJ Open; 2014 Mar; 4(3):e004253. PubMed ID: 24622948
[TBL] [Abstract][Full Text] [Related]
6. Postoperative monitoring of lower limb free flaps with the Cook-Swartz implantable Doppler probe: A clinical trial.
Rozen WM; Enajat M; Whitaker IS; Lindkvist U; Audolfsson T; Acosta R
Microsurgery; 2010 Jul; 30(5):354-60. PubMed ID: 19967762
[TBL] [Abstract][Full Text] [Related]
7. Evaluation of the Implantable Doppler Probe for Free Flap Monitoring in Lower Limb Reconstruction.
Lenz Y; Gross R; Penna V; Bannasch H; Stark GB; Eisenhardt SU
J Reconstr Microsurg; 2018 Mar; 34(3):218-226. PubMed ID: 29179224
[TBL] [Abstract][Full Text] [Related]
8. Implantable Doppler Ultrasound Monitoring in Head and Neck Free Flaps: Balancing the Pros and Cons.
Hayler R; Low TH; Fung K; Nichols AC; MacNeil SD; Yoo J
Laryngoscope; 2021 Jun; 131(6):E1854-E1859. PubMed ID: 33141464
[TBL] [Abstract][Full Text] [Related]
9. The implantable Cook-Swartz Doppler probe for postoperative monitoring in head and neck free flap reconstruction.
Guillemaud JP; Seikaly H; Cote D; Allen H; Harris JR
Arch Otolaryngol Head Neck Surg; 2008 Jul; 134(7):729-34. PubMed ID: 18645123
[TBL] [Abstract][Full Text] [Related]
10. Deciphering the Sensitivity and Specificity of the Implantable Doppler Probe in Free Flap Monitoring.
Chang EI; Ibrahim A; Zhang H; Liu J; Nguyen AT; Reece GP; Yu P
Plast Reconstr Surg; 2016 Mar; 137(3):971-976. PubMed ID: 26910681
[TBL] [Abstract][Full Text] [Related]
11. [Implantable doppler probe for microsurgical free flap monitoring in cervico-facial reconstructive surgery].
Clert V; Guédon C; Cristofari JP; Halimi C; Barry B; Albert S
Ann Chir Plast Esthet; 2013 Apr; 58(2):82-8. PubMed ID: 23399512
[TBL] [Abstract][Full Text] [Related]
12. Retrospective evaluation of diagnostic accuracy of free flap monitoring with the Cook-Swartz-Doppler probe in head and neck reconstruction.
Leibig N; Ha-Phuoc A; Stark GB; Schmelzeisen R; Metzger MC; Eisenhardt SU; Voss PJ
J Craniomaxillofac Surg; 2019 Dec; 47(12):1973-1979. PubMed ID: 31810844
[TBL] [Abstract][Full Text] [Related]
13. A chimaeric-pattern flap design for implantable Doppler surrogate monitoring: a novel placement technique.
Kim JT; Ho SY; Kim YH
J Plast Reconstr Aesthet Surg; 2014 Feb; 67(2):190-7. PubMed ID: 24365566
[TBL] [Abstract][Full Text] [Related]
14. Implantable venous Doppler monitoring in head and neck free flap reconstruction increases the salvage rate.
Paydar KZ; Hansen SL; Chang DS; Hoffman WY; Leon P
Plast Reconstr Surg; 2010 Apr; 125(4):1129-1134. PubMed ID: 20335864
[TBL] [Abstract][Full Text] [Related]
15. Implantable Doppler Removal After Free Flap Monitoring Among Head and Neck Microvascular Surgeons.
Ong AA; Ducic Y; Pipkorn P; Wax MK
Laryngoscope; 2022 Mar; 132(3):554-559. PubMed ID: 34363218
[TBL] [Abstract][Full Text] [Related]
16. Adjunctive technologies in postoperative free-flap monitoring: a systematic review.
Lacey H; Kanakopoulos D; Hussein S; Moyasser O; Ward J; King ICC
J Plast Reconstr Aesthet Surg; 2023 Dec; 87():147-155. PubMed ID: 37844383
[TBL] [Abstract][Full Text] [Related]
17. A comparison of the Cook-Swartz Doppler with conventional clinical methods for free flap monitoring: A systematic review and a meta-analysis.
Han ZF; Guo LL; Liu LB; Li Q; Zhou J; Wei AZ; Guo PF
Int J Surg; 2016 Aug; 32():109-15. PubMed ID: 27353849
[TBL] [Abstract][Full Text] [Related]
18. Buried free flaps in head and neck surgery: outcome analysis.
Lindau RH; Detwiller K; Wax MK
Head Neck; 2013 Oct; 35(10):1468-70. PubMed ID: 22972695
[TBL] [Abstract][Full Text] [Related]
19. The Cook-Swartz venous Doppler probe for the post-operative monitoring of free tissue transfers in the United Kingdom: a preliminary report.
Oliver DW; Whitaker IS; Giele H; Critchley P; Cassell O
Br J Plast Surg; 2005 Apr; 58(3):366-70. PubMed ID: 15780232
[TBL] [Abstract][Full Text] [Related]
20. Outcomes and reliability of the flow coupler in postoperative monitoring of head and neck free flaps.
Fujiwara RJT; Dibble JM; Larson SV; Pierce ML; Mehra S
Laryngoscope; 2018 Apr; 128(4):812-817. PubMed ID: 28988465
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]