142 related articles for article (PubMed ID: 3594984)
1. Femoral cement removal in revision total hip arthroplasty. A biomechanical analysis.
Dennis DA; Dingman CA; Meglan DA; O'Leary JF; Mallory TH; Berme N
Clin Orthop Relat Res; 1987 Jul; (220):142-7. PubMed ID: 3594984
[TBL] [Abstract][Full Text] [Related]
2. In vitro measurement of strain in the bone cement surrounding the femoral component of total hip replacements during simulated gait and stair-climbing.
O'Connor DO; Burke DW; Jasty M; Sedlacek RC; Harris WH
J Orthop Res; 1996 Sep; 14(5):769-77. PubMed ID: 8893771
[TBL] [Abstract][Full Text] [Related]
3. Femoral cement pressurisation for hip arthroplasty in previously fixated hips: an experimental study.
McMahon SE; Alvi F; Lemon JG; Lovell ME
Injury; 2010 Apr; 41(4):352-5. PubMed ID: 19828147
[TBL] [Abstract][Full Text] [Related]
4. Femoral windows in revision total hip arthroplasty.
Klein AH; Rubash HE
Clin Orthop Relat Res; 1993 Jun; (291):164-70. PubMed ID: 8504595
[TBL] [Abstract][Full Text] [Related]
5. Modified transfemoral approach to revision arthroplasty with uncemented modular revision stems.
Fink B; Grossmann A
Oper Orthop Traumatol; 2007 Mar; 19(1):32-55. PubMed ID: 17345026
[TBL] [Abstract][Full Text] [Related]
6. Effects of stem length on mechanics of the femoral hip component after cemented revision.
Mann KA; Ayers DC; Damron TA
J Orthop Res; 1997 Jan; 15(1):62-8. PubMed ID: 9066528
[TBL] [Abstract][Full Text] [Related]
7. [A simple technique of removal of femoral cement plug in total hip prosthesis revision].
Julliard R
Rev Chir Orthop Reparatrice Appar Mot; 1996; 82(2):161-5. PubMed ID: 8761102
[TBL] [Abstract][Full Text] [Related]
8. [Mathematical simulation of stem/cement/bone mechanical interactions for Poldi-Cech, CF-30, MS-30 and PFC femoral components].
Kovanda M; Havlícek V; Hudec J
Acta Chir Orthop Traumatol Cech; 2009 Apr; 76(2):110-5. PubMed ID: 19439130
[TBL] [Abstract][Full Text] [Related]
9. [Early aseptic loosening of the CF 30 femoral stem].
Kovanda M; Havlícek V; Hudec J
Acta Chir Orthop Traumatol Cech; 2007 Feb; 74(1):59-64. PubMed ID: 17331456
[TBL] [Abstract][Full Text] [Related]
10. [Femoral reconstruction with endosteal bone allografts protected by a metallic mesh in reoperation of total hip prosthesis. 19 cases with an average follow-up of 83 months].
Migaud H; Jardin C; Fontaine C; Pierchon F; d'Herbomez O; Duquennoy A
Rev Chir Orthop Reparatrice Appar Mot; 1997; 83(4):360-7. PubMed ID: 9452810
[TBL] [Abstract][Full Text] [Related]
11. Effects of variation of cement thickness on bone and cement stress at the tip of a femoral implant.
Lee IY; Skinner HB; Keyak JH
Iowa Orthop J; 1993; 13():155-9. PubMed ID: 7820736
[TBL] [Abstract][Full Text] [Related]
12. Preparation of the proximal femur in cementless total hip revision.
Mallory TH
Clin Orthop Relat Res; 1988 Oct; (235):47-60. PubMed ID: 3416541
[TBL] [Abstract][Full Text] [Related]
13. Computer-assisted fluoroscopic navigation system for removal of distal femoral bone cement in revision total hip arthroplasty.
Akiyama H; Kawanabe K; Goto K; Ohnishi E; Nakamura T
J Arthroplasty; 2007 Apr; 22(3):445-8. PubMed ID: 17400101
[TBL] [Abstract][Full Text] [Related]
14. In vitro cyclic testing of the Exeter stem after cement within cement revision.
Wilson LJ; Bell CG; Weinrauch P; Crawford R
J Arthroplasty; 2009 Aug; 24(5):789-94. PubMed ID: 18534400
[TBL] [Abstract][Full Text] [Related]
15. Work-in-progress #1. The lithotriptor and its potential use in the revision of total hip arthroplasty.
Karpman RR; Magee FP; Gruen TW; Mobley T
Orthop Rev; 1987 Jan; 16(1):38-42. PubMed ID: 3453956
[TBL] [Abstract][Full Text] [Related]
16. Reaming versus broaching in cemented hip arthroplasty: mechanical stability in cadaver femora.
Ioannidis TT; Apostolou CD; Korres DS; Papaletsos I; Gandaifis ND; Panagopoulos CN; Agathocleous PE
Acta Orthop; 2005 Jun; 76(3):326-30. PubMed ID: 16156458
[TBL] [Abstract][Full Text] [Related]
17. Uncemented femoral revision arthroplasty using the modular revision prosthesis MRP-TITAN revision stem.
Mumme T; Müller-Rath R; Andereya S; Wirtz DC
Oper Orthop Traumatol; 2007 Mar; 19(1):56-77. PubMed ID: 17345027
[TBL] [Abstract][Full Text] [Related]
18. Precooling of the femoral canal enhances shear strength at the cement-prosthesis interface and reduces the polymerization temperature.
Hsieh PH; Tai CL; Chang YH; Lee MS; Shih HN; Shih CH
J Orthop Res; 2006 Sep; 24(9):1809-14. PubMed ID: 16865715
[TBL] [Abstract][Full Text] [Related]
19. [Initial stability of an implanted cement-canal prosthesis. Results in experimental studies on human cadaver femurs].
Jansson V; Zimmer M; Kühne JH; Sailer FP
Z Orthop Ihre Grenzgeb; 1993; 131(4):377-81. PubMed ID: 8212817
[TBL] [Abstract][Full Text] [Related]
20. The effect of femoral prosthesis design on cement strain in cemented total hip arthroplasty.
Peters CL; Bachus KN; Craig MA; Higginbotham TO
J Arthroplasty; 2001 Feb; 16(2):216-24. PubMed ID: 11222897
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]