BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

141 related articles for article (PubMed ID: 3595144)

  • 21. [Clinical experience in 3 cases, 5 events of thrombosed Björk-Shiley mitral prostheses].
    Kuwaki K; Matsuzaki T; Ichinomiya Y; Harada H; Ueda M; Komatsu S
    Kyobu Geka; 1993 Jun; 46(6):498-502. PubMed ID: 8315921
    [TBL] [Abstract][Full Text] [Related]  

  • 22. [Long-term follow-up of aortic or mitral valve replacement. Comparison of results following implantation of a mechanical or biological artificial valve].
    Mudra H; Rudolph W
    Herz; 1986 Apr; 11(2):97-115. PubMed ID: 3699678
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Thrombotic obstruction of the Björk-Shiley valve: the Glasgow experience.
    Ryder SJ; Bradley H; Brannan JJ; Turner MA; Bain WH
    Thorax; 1984 Jul; 39(7):487-92. PubMed ID: 6463927
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Outlet strut fracture of a 23-mm Björk-Shiley 70 degrees convexo-concave aortic valve.
    Abad C
    Cardiovasc Surg; 1993 Aug; 1(4):445-6. PubMed ID: 8076078
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Comparison of porcine valve xenografts with mechanical prostheses. A 7 1/2 year experience.
    Joyce LD; Nelson RM
    J Thorac Cardiovasc Surg; 1984 Jul; 88(1):102-13. PubMed ID: 6738092
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Thrombosis of mitral valve prosthesis presenting as abdominal pain.
    Mylonakis E; Kon D; Moulton A; Elion J; Indeglia R; Koutkia P; Katz A
    Heart Lung; 1999; 28(2):110-3. PubMed ID: 10076110
    [TBL] [Abstract][Full Text] [Related]  

  • 27. [Late thromboses on tricuspid valve prostheses. Apropos of 6 cases].
    Ben-Ismail M; Abid F; Sirinelle A; Curran Y
    Arch Mal Coeur Vaiss; 1981 Mar; 74(3):289-96. PubMed ID: 6782989
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Thrombosis of the Björk-Shiley prosthesis: illustrative cases and review of the literature.
    Wright JO; Hiratzka LF; Brandt B; Doty DB
    J Thorac Cardiovasc Surg; 1982 Jul; 84(1):138-44. PubMed ID: 7087530
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Valve adaptation as a cause of disc opening reduction in mechanical heart valves: the case of the Lillehei-Kaster valve.
    Montorsi P; Teruzzi G; Calligaris G; Cavoretto D
    Ital Heart J; 2003 Feb; 4(2):134-8. PubMed ID: 12762278
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Misleading noninvasive signs of Bjork--Shiley mitral valve dysfunction.
    Carliner NH; Plotnick GD; Vassar DL; Donahoo JS; DeFelice CE; Fisher ML
    Johns Hopkins Med J; 1978 Nov; 143(5):160-2. PubMed ID: 723111
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Thrombosis on Björk-Shiley aortic valve prosthesis. A case report and review of the literature.
    Krausz Y; Appelbaum A; Halon DA; David D
    Isr J Med Sci; 1977 Apr; 13(4):410-3. PubMed ID: 873761
    [TBL] [Abstract][Full Text] [Related]  

  • 32. [Dysfunction of valvular prostheses. Results of surgical treatment].
    Villalba RJ; Quijano-Pitman F
    Arch Inst Cardiol Mex; 1982; 52(4):329-34. PubMed ID: 7138136
    [TBL] [Abstract][Full Text] [Related]  

  • 33. [Thrombosis and thromboembolism in patients with a Björk-Shiley prosthesis].
    Hricák V; Kovácik M; Fridrich V
    Vnitr Lek; 1989 Apr; 35(4):340-3. PubMed ID: 2741353
    [TBL] [Abstract][Full Text] [Related]  

  • 34. [Bj"ork-Shiley heart vales at the Bern University Hospital. Long-term follow-up of 12 to 23 years after mitral and aortic valve replacement in 503 patients].
    Stuber T; Kaufmann U; Kipfer B; Meier B
    Praxis (Bern 1994); 1999 Feb; 88(9):355-63. PubMed ID: 10191683
    [TBL] [Abstract][Full Text] [Related]  

  • 35. [Thrombosed mechanical heart valve prostheses].
    Hayashi J
    Kyobu Geka; 2004 Jul; 57(8 Suppl):642-8. PubMed ID: 15362539
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Comparative analysis of mechanical and bioprosthetic valves after aortic valve replacement.
    Borkon AM; Soule LM; Baughman KL; Aoun H; Baumgartner WA; Gardner TJ; Watkins L; Gott VL; Reitz BA
    J Thorac Cardiovasc Surg; 1987 Jul; 94(1):20-33. PubMed ID: 3600005
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Thrombotic obstruction of aortic, mitral, and tricuspid Björk-Shiley prostheses in the same patient.
    Bortolotti U; Faggian G; Mazzucco A; Stellin G; Gallucci V
    Thorac Cardiovasc Surg; 1986 Jun; 34(3):196-7. PubMed ID: 2426837
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Acute postoperative block of mechanical prostheses: incidence and treatment.
    Santé P; Renzulli A; Festa M; Vitale N; Mollo A; Dialetto G; De Luca L
    Cardiovasc Surg; 1994 Jun; 2(3):403-6. PubMed ID: 8049985
    [TBL] [Abstract][Full Text] [Related]  

  • 39. An examination of two retrieved long-term human implant Björk-Shiley valves.
    More RB
    Med Prog Technol; 1994; 20(3-4):195-200. PubMed ID: 7877565
    [TBL] [Abstract][Full Text] [Related]  

  • 40. [Long-term results over 20 years of aortic valve replacement with the standard Björk-Shiley prosthesis].
    Valla J; Langanay T; Corbineau H; Sevray B; Chaperon J; Menestret P; Lelong B; Leguerrier A; Rioux C; Logeais Y
    Arch Mal Coeur Vaiss; 1996 Sep; 89(9):1137-43. PubMed ID: 8952837
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 8.