157 related articles for article (PubMed ID: 35955331)
1. A Comparative Study of Additive and Subtractive Manufacturing Techniques for a Zirconia Dental Product: An Analysis of the Manufacturing Accuracy and the Bond Strength of Porcelain to Zirconia.
Moon JM; Jeong CS; Lee HJ; Bae JM; Choi EJ; Kim ST; Park YB; Oh SH
Materials (Basel); 2022 Aug; 15(15):. PubMed ID: 35955331
[TBL] [Abstract][Full Text] [Related]
2. Additive Manufacturing of Dental Ceramics: A Systematic Review and Meta-Analysis.
Al Hamad KQ; Al-Rashdan BA; Ayyad JQ; Al Omrani LM; Sharoh AM; Al Nimri AM; Al-Kaff FT
J Prosthodont; 2022 Oct; 31(8):e67-e86. PubMed ID: 35675133
[TBL] [Abstract][Full Text] [Related]
3. A comparative study of additive and subtractive manufacturing for dental restorations.
Bae EJ; Jeong ID; Kim WC; Kim JH
J Prosthet Dent; 2017 Aug; 118(2):187-193. PubMed ID: 28089336
[TBL] [Abstract][Full Text] [Related]
4. Suitability of 3D printed pieces of nanocrystalline zirconia for dental applications.
Branco AC; Silva R; Santos T; Jorge H; Rodrigues AR; Fernandes R; Bandarra S; Barahona I; Matos APA; Lorenz K; Polido M; Colaço R; Serro AP; Figueiredo-Pina CG
Dent Mater; 2020 Mar; 36(3):442-455. PubMed ID: 32001023
[TBL] [Abstract][Full Text] [Related]
5. The Flexural Strength and Flexural Modulus of Stereolithography Additively Manufactured Zirconia with Different Porosities.
Zandinejad A; Das O; Barmak AB; Kuttolamadom M; Revilla-León M
J Prosthodont; 2022 Jun; 31(5):434-440. PubMed ID: 34580962
[TBL] [Abstract][Full Text] [Related]
6. Geometrical accuracy of metallic objects produced with additive or subtractive manufacturing: A comparative in vitro study.
Braian M; Jönsson D; Kevci M; Wennerberg A
Dent Mater; 2018 Jul; 34(7):978-993. PubMed ID: 29631870
[TBL] [Abstract][Full Text] [Related]
7. Additive Manufacturing of Zirconia Ceramic and Its Application in Clinical Dentistry: A Review.
Khanlar LN; Salazar Rios A; Tahmaseb A; Zandinejad A
Dent J (Basel); 2021 Sep; 9(9):. PubMed ID: 34562978
[TBL] [Abstract][Full Text] [Related]
8. Chemical composition, surface roughness, and ceramic bond strength of additively manufactured cobalt-chromium dental alloys.
Revilla-León M; Al-Haj Husain N; Methani MM; Özcan M
J Prosthet Dent; 2021 May; 125(5):825-831. PubMed ID: 32466963
[TBL] [Abstract][Full Text] [Related]
9. Accuracy of additively manufactured zirconia four-unit fixed dental prostheses fabricated by stereolithography, digital light processing and material jetting compared with subtractive manufacturing.
Lüchtenborg J; Willems E; Zhang F; Wesemann C; Weiss F; Nold J; Sun J; Sandra F; Bai J; Reveron H; Chevalier J; Spies BC
Dent Mater; 2022 Sep; 38(9):1459-1469. PubMed ID: 35798578
[TBL] [Abstract][Full Text] [Related]
10. Effect of feldspathic porcelain layering on the marginal fit of zirconia and titanium complete-arch fixed implant-supported frameworks.
Yilmaz B; Alshahrani FA; Kale E; Johnston WM
J Prosthet Dent; 2018 Jul; 120(1):71-78. PubMed ID: 29426786
[TBL] [Abstract][Full Text] [Related]
11. Influence of zirconia surface treatment on veneering porcelain shear bond strength after cyclic loading.
Nishigori A; Yoshida T; Bottino MC; Platt JA
J Prosthet Dent; 2014 Dec; 112(6):1392-8. PubMed ID: 25258263
[TBL] [Abstract][Full Text] [Related]
12. Bond strength of the porcelain repair system to all-ceramic copings and porcelain.
Lee SJ; Cheong CW; Wright RF; Chang BM
J Prosthodont; 2014 Feb; 23(2):112-6. PubMed ID: 23725343
[TBL] [Abstract][Full Text] [Related]
13. Flexural strength and Weibull characteristics of stereolithography additive manufactured versus milled zirconia.
Revilla-León M; Al-Haj Husain N; Ceballos L; Özcan M
J Prosthet Dent; 2021 Apr; 125(4):685-690. PubMed ID: 32434662
[TBL] [Abstract][Full Text] [Related]
14. A comparative evaluation of shear bond strength between feldspathic porcelain and lithium di silicate ceramic layered to a zirconia core- An
Moses A; Ganesan L; Shankar S; Hariharan A
J Clin Exp Dent; 2020 Nov; 12(11):e1039-e1044. PubMed ID: 33262869
[TBL] [Abstract][Full Text] [Related]
15. Shear bond strength of veneering porcelain to zirconia: Effect of surface treatment by CNC-milling and composite layer deposition on zirconia.
Santos RLP; Silva FS; Nascimento RM; Souza JCM; Motta FV; Carvalho O; Henriques B
J Mech Behav Biomed Mater; 2016 Jul; 60():547-556. PubMed ID: 27058002
[TBL] [Abstract][Full Text] [Related]
16. Mechanical properties of additively manufactured zirconia with alumina air abrasion surface treatment.
Yoo LG; Pang NS; Kim SH; Jung BY
Sci Rep; 2023 Jun; 13(1):9153. PubMed ID: 37280320
[TBL] [Abstract][Full Text] [Related]
17. Fracture and shear bond strength analyses of different dental veneering ceramics to zirconia.
Diniz AC; Nascimento RM; Souza JC; Henriques BB; Carreiro AF
Mater Sci Eng C Mater Biol Appl; 2014 May; 38():79-84. PubMed ID: 24656355
[TBL] [Abstract][Full Text] [Related]
18. Effect of coloring liquids on color of zirconia frameworks and bond strength of zirconia/veneering ceramic.
Celik S; Ucar Y; Ekren O
J Prosthet Dent; 2020 Jul; 124(1):110-115. PubMed ID: 32204927
[TBL] [Abstract][Full Text] [Related]
19. Evaluation of a conditioning method to improve core-veneer bond strength of zirconia restorations.
Teng J; Wang H; Liao Y; Liang X
J Prosthet Dent; 2012 Jun; 107(6):380-7. PubMed ID: 22633594
[TBL] [Abstract][Full Text] [Related]
20. Influence of surface airborne-particle abrasion and bonding agent application on porcelain bonding to titanium dental alloys fabricated by milling and by selective laser melting.
Antanasova M; Kocjan A; Hočevar M; Jevnikar P
J Prosthet Dent; 2020 Mar; 123(3):491-499. PubMed ID: 31307799
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]