These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

122 related articles for article (PubMed ID: 35961919)

  • 21. Electrochemical oxidation of cysteine at a film gold modified carbon fiber microelectrode its application in a flow-through voltammetric sensor.
    Wang LH; Huang WS
    Sensors (Basel); 2012; 12(3):3562-77. PubMed ID: 22737024
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Ferricyanide-backfilled cylindrical carbon fiber microelectrodes for in vivo analysis with high stability and low polarized potential.
    Zhong P; Yu P; Wang K; Hao J; Fei J; Mao L
    Analyst; 2015 Nov; 140(21):7154-9. PubMed ID: 26378690
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Hydrogel-Coated Microelectrode Resists Protein Passivation of In Vivo Amperometric Sensors.
    Yin Y; Zeng H; Zhang S; Gao N; Liu R; Cheng S; Zhang M
    Anal Chem; 2023 Feb; 95(6):3390-3397. PubMed ID: 36725686
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Highly sensitive detection of exocytotic dopamine release using a gold-nanoparticle-network microelectrode.
    Adams KL; Jena BK; Percival SJ; Zhang B
    Anal Chem; 2011 Feb; 83(3):920-7. PubMed ID: 21175175
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Evaluation of carbon nanotube fiber microelectrodes for neurotransmitter detection: Correlation of electrochemical performance and surface properties.
    Yang C; Trikantzopoulos E; Jacobs CB; Venton BJ
    Anal Chim Acta; 2017 May; 965():1-8. PubMed ID: 28366206
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Carbon powder-filled microelectrode: An easy-to-fabricate probe for cellular electrochemistry.
    Tsujimura A; Kamae Y; Kawasaki H; Nagai H; Kano M; Tabata T
    Anal Biochem; 2021 Sep; 629():114316. PubMed ID: 34314725
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Hybrid diamond/ carbon fiber microelectrodes enable multimodal electrical/chemical neural interfacing.
    Hejazi MA; Tong W; Stacey A; Soto-Breceda A; Ibbotson MR; Yunzab M; Maturana MI; Almasi A; Jung YJ; Sun S; Meffin H; Fang J; Stamp MEM; Ganesan K; Fox K; Rifai A; Nadarajah A; Falahatdoost S; Prawer S; Apollo NV; Garrett DJ
    Biomaterials; 2020 Feb; 230():119648. PubMed ID: 31791841
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Evaluating the diffusion coefficient of dopamine at the cell surface during amperometric detection: disk vs ring microelectrodes.
    Trouillon R; Lin Y; Mellander LJ; Keighron JD; Ewing AG
    Anal Chem; 2013 Jul; 85(13):6421-8. PubMed ID: 23706095
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Flexible nanohybrid microelectrode based on carbon fiber wrapped by gold nanoparticles decorated nitrogen doped carbon nanotube arrays: In situ electrochemical detection in live cancer cells.
    Zhang Y; Xiao J; Sun Y; Wang L; Dong X; Ren J; He W; Xiao F
    Biosens Bioelectron; 2018 Feb; 100():453-461. PubMed ID: 28963962
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Static and Dynamic Measurement of Dopamine Adsorption in Carbon Fiber Microelectrodes Using Electrochemical Impedance Spectroscopy.
    Rivera-Serrano N; Pagan M; Colón-Rodríguez J; Fuster C; Vélez R; Almodovar-Faria J; Jiménez-Rivera C; Cunci L
    Anal Chem; 2018 Feb; 90(3):2293-2301. PubMed ID: 29260558
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Temporal resolution in electrochemical imaging on single PC12 cells using amperometry and voltammetry at microelectrode arrays.
    Zhang B; Heien ML; Santillo MF; Mellander L; Ewing AG
    Anal Chem; 2011 Jan; 83(2):571-7. PubMed ID: 21190375
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Carbon nanotube fiber microelectrodes show a higher resistance to dopamine fouling.
    Harreither W; Trouillon R; Poulin P; Neri W; Ewing AG; Safina G
    Anal Chem; 2013 Aug; 85(15):7447-53. PubMed ID: 23789970
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Selective Amperometric Recording of Endogenous Ascorbate Secretion from a Single Rat Adrenal Chromaffin Cell with Pretreated Carbon Fiber Microelectrodes.
    Wang K; Xiao T; Yue Q; Wu F; Yu P; Mao L
    Anal Chem; 2017 Sep; 89(17):9502-9507. PubMed ID: 28776368
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Development of amperometric α-ketoglutarate biosensor based on ruthenium-rhodium modified carbon fiber enzyme microelectrode.
    Poorahong S; Santhosh P; Ramírez GV; Tseng TF; Wong JI; Kanatharana P; Thavarungkul P; Wang J
    Biosens Bioelectron; 2011 Apr; 26(8):3670-3. PubMed ID: 21334188
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Vertically aligned carbon nanotube-sheathed carbon fibers as pristine microelectrodes for selective monitoring of ascorbate in vivo.
    Xiang L; Yu P; Hao J; Zhang M; Zhu L; Dai L; Mao L
    Anal Chem; 2014 Apr; 86(8):3909-14. PubMed ID: 24678660
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Controllable and Reproducible Sheath of Carbon Fibers with Single-Walled Carbon Nanotubes through Electrophoretic Deposition for In Vivo Electrochemical Measurements.
    Xiao T; Jiang Y; Ji W; Mao L
    Anal Chem; 2018 Apr; 90(7):4840-4846. PubMed ID: 29517222
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Development and characterization of a voltammetric carbon-fiber microelectrode pH sensor.
    Makos MA; Omiatek DM; Ewing AG; Heien ML
    Langmuir; 2010 Jun; 26(12):10386-91. PubMed ID: 20380393
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Gold Nanoparticle Modified Carbon Fiber Microelectrodes for Enhanced Neurochemical Detection.
    Mohanaraj S; Wonnenberg P; Cohen B; Zhao H; Hartings MR; Zou S; Fox DM; Zestos AG
    J Vis Exp; 2019 May; (147):. PubMed ID: 31132067
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Nanodiamond Coating Improves the Sensitivity and Antifouling Properties of Carbon Fiber Microelectrodes.
    Puthongkham P; Venton BJ
    ACS Sens; 2019 Sep; 4(9):2403-2411. PubMed ID: 31387349
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Highly Uniform, Flexible Microelectrodes Based on the Clean Single-Walled Carbon Nanotube Thin Film with High Electrochemical Activity.
    Viet NX; Kishimoto S; Ohno Y
    ACS Appl Mater Interfaces; 2019 Feb; 11(6):6389-6395. PubMed ID: 30672689
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 7.