These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

49 related articles for article (PubMed ID: 3596224)

  • 21. Patch voltage clamp of squid axon membrane.
    Fishman HM
    J Membr Biol; 1975 Dec; 24(3-4):265-77. PubMed ID: 1214276
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Analysis of cable properties under hypoxia in cardiac muscles.
    Ikeda K
    Bull Tokyo Med Dent Univ; 1980 Dec; 27(4):151-7. PubMed ID: 6936092
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Some technical improvements for the voltage clamp with the double sucrose gap.
    LĂ©oty C; Alix J
    Pflugers Arch; 1976 Sep; 365(1):95-7. PubMed ID: 988547
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Reexamination of the double sucrose gap technique for the study of lobster giant axons. Theory and experiments.
    Pooler JP; Valenzeno DP
    Biophys J; 1983 Nov; 44(2):261-9. PubMed ID: 6652217
    [TBL] [Abstract][Full Text] [Related]  

  • 25. [Discontinuous feedback amplifier: principles and application to the measurement of transmembrane potentials and currents of frog atrial fibers].
    Suchaud M; Chesnais JM; Sauviat MP
    C R Acad Sci III; 1986; 302(1):15-20. PubMed ID: 3082473
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Voltage clamp analysis in isolated cardiac fibres as performed with two different perfusion chambres for double sucrose gap.
    de Hemptinne A
    Pflugers Arch; 1976 May; 363(1):87-95. PubMed ID: 1083972
    [TBL] [Abstract][Full Text] [Related]  

  • 27. The potential distribution and the short-circuiting factor in the sucrose gap.
    Jirounek P; Straub RW
    Biophys J; 1971 Jan; 11(1):1-10. PubMed ID: 5538998
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Passive membrane properties of motorneurons and their role in long-distance signaling in the nematode Ascaris.
    Davis RE; Stretton AO
    J Neurosci; 1989 Feb; 9(2):403-14. PubMed ID: 2918369
    [TBL] [Abstract][Full Text] [Related]  

  • 29. A theoretical study on the sucrose gap technique as applied to multicellular muscle preparations. I. Saline-sucrose interdiffusion.
    Lammel E
    Biophys J; 1981 Dec; 36(3):533-53. PubMed ID: 7326323
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Electrical resistance of muscle capillary endothelium.
    Olesen SP; Crone C
    Biophys J; 1983 Apr; 42(1):31-41. PubMed ID: 6601500
    [TBL] [Abstract][Full Text] [Related]  

  • 31. The lens as a nonuniform spherical syncytium.
    Mathias RT; Rae JL; Eisenberg RS
    Biophys J; 1981 Apr; 34(1):61-83. PubMed ID: 7213932
    [TBL] [Abstract][Full Text] [Related]  

  • 32. On the relation between axial resistance and conductivity in linear cable models.
    Kleinpenning PH; Van Oosterom A
    Math Biosci; 1990 Apr; 99(1):1-10. PubMed ID: 2134509
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Analysis of lumped and distributed elements models of cut muscle fibers in vaseline or sucrose gap preparations.
    Andrietti F; Bernardini G; Peres A
    Biophys J; 1984 Nov; 46(5):625-30. PubMed ID: 6498275
    [TBL] [Abstract][Full Text] [Related]  

  • 34. [Standardization of the resistance of grounded electrocardiographs with patient circuits ground-insulated to electrical cophase interferences from an external main].
    Rybakov AM
    Med Tekh; 1977; (3):27-34. PubMed ID: 886948
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Control of membrane potential in double sucrose gap voltage clamp technique.
    Horackova M; Shrier A; Vassort G
    Circ Res; 1977 Jun; 40(6):603-5. PubMed ID: 858181
    [No Abstract]   [Full Text] [Related]  

  • 36. Analysis of the longitudinal and radial resistivity measurements of the nerve trunk.
    Altman KW; Plonsey R
    Ann Biomed Eng; 1989; 17(4):313-24. PubMed ID: 2774310
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Signal processor for direct current-voltage plotting of voltage-clamp data.
    Schwartz JL
    Med Biol Eng Comput; 1977 Jul; 15(4):455-61. PubMed ID: 197342
    [No Abstract]   [Full Text] [Related]  

  • 38. Dependence of the contact resistance on the design of stranded conductors.
    Zeroukhi Y; Napieralska-Juszczak E; Vega G; Komeza K; Morganti F; Wiak S
    Sensors (Basel); 2014 Jul; 14(8):13925-42. PubMed ID: 25196112
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Voltage clamp simulations for multifiber bundles in a double sucrose gap: radial vs. longitudinal resistance effects.
    Haas HG; Brommundt G; Solchenbach K
    Gen Physiol Biophys; 1987 Feb; 6(1):3-18. PubMed ID: 3596224
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Voltage clamp simulations for multifiber bundles in a double sucrose gap: cable complications.
    Solchenbach K; Haas HG; Brommundt G
    Gen Physiol Biophys; 1986 Oct; 5(5):449-71. PubMed ID: 2433182
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 3.