These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

148 related articles for article (PubMed ID: 35976574)

  • 1. Locking in trochanteric fractures: a comparison of static versus dynamic locking using the Gamma3 nail.
    Hulshof GWL; van der Stelt M; Schutte H; van Koperen PJ; Timmers TK; van Olden GDJ; Kluijfhout WP
    Eur J Orthop Surg Traumatol; 2023 Jul; 33(5):1797-1804. PubMed ID: 35976574
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Proximal Femoral Nail Unlocked versus Locked (ProFNUL): a protocol for a multicentre, parallel-armed randomised controlled trial for the effect of femoral nail mode of lag screw locking and screw configuration in the treatment of intertrochanteric femur fractures.
    Sivakumar A; Thewlis D; Ladurner A; Edwards S; Rickman M
    BMJ Open; 2020 Feb; 10(2):e032640. PubMed ID: 32047013
    [TBL] [Abstract][Full Text] [Related]  

  • 3. [Comparison of 2-Screw Implant and Antirotational Blade Implant in Treatment of Trochanteric Fractures].
    FeldinszkÁ J; Jacko P; Barinka J; Kilian M; Šimko P
    Acta Chir Orthop Traumatol Cech; 2020; 87(4):268-272. PubMed ID: 32940222
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Gamma and other cephalocondylic intramedullary nails versus extramedullary implants for extracapsular hip fractures in adults.
    Parker MJ; Handoll HH
    Cochrane Database Syst Rev; 2008 Jul; (3):CD000093. PubMed ID: 18646058
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Comparison and analysis of reoperations in two different treatment protocols for trochanteric hip fractures - postoperative technical complications with dynamic hip screw, intramedullary nail and Medoff sliding plate.
    Paulsson J; Stig JC; Olsson O
    BMC Musculoskelet Disord; 2017 Aug; 18(1):364. PubMed ID: 28836973
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Does Computer-assisted Surgery Improve Lag Screw Placement During Cephalomedullary Nailing of Intertrochanteric Hip Fractures?
    Kuhl M; Beimel C
    Clin Orthop Relat Res; 2020 Sep; 478(9):2132-2144. PubMed ID: 32496321
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Causes and treatments of lag screw's cut out after intramedullary nailing osteosinthesis for trochanteric fractures.
    Gazzotti G; Matino G; Tsatsis C; Sacchetti G; Baudi P; Catani F
    Acta Biomed; 2014 Aug; 85(2):135-43. PubMed ID: 25245649
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Single-centre results of a randomised controlled trial comparing the Gamma3 nail and a sliding hip screw to treat AO type 31-A1 and 31-A2 trochanteric fractures.
    Hempel EK; Wendlandt R; Unger A; Frese J; Wilde E; Schulz AP
    Langenbecks Arch Surg; 2024 Oct; 409(1):310. PubMed ID: 39419825
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Gamma and other cephalocondylic intramedullary nails versus extramedullary implants for extracapsular hip fractures.
    Parker MJ; Handoll HH
    Cochrane Database Syst Rev; 2002; (1):CD000093. PubMed ID: 11869563
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Gamma3 nail with U-Blade (RC) lag screw is effective with better surgical outcomes in trochanteric hip fractures.
    Han SB; Jung JK; Jang CY; Kwak DK; Kim JW; Yoo JH
    Sci Rep; 2020 Apr; 10(1):6021. PubMed ID: 32265481
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Gamma and other cephalocondylic intramedullary nails versus extramedullary implants for extracapsular hip fractures.
    Parker MJ; Handoll HH
    Cochrane Database Syst Rev; 2002; (4):CD000093. PubMed ID: 12519535
    [TBL] [Abstract][Full Text] [Related]  

  • 12. How evolution of the nailing system improves results and reduces orthopedic complications: more than 2000 cases of trochanteric fractures treated with the Gamma Nail System.
    Pascarella R; Fantasia R; Maresca A; Bettuzzi C; Amendola L; Violini S; Cuoghi F; Sangiovanni P; Cerbasi S; Boriani S; Tigani DS
    Musculoskelet Surg; 2016 Apr; 100(1):1-8. PubMed ID: 26667625
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Gamma and other cephalocondylic intramedullary nails versus extramedullary implants for extracapsular hip fractures in adults.
    Parker MJ; Handoll HH
    Cochrane Database Syst Rev; 2005 Oct; (4):CD000093. PubMed ID: 16235272
    [TBL] [Abstract][Full Text] [Related]  

  • 14. A newly designed locked intramedullary nail for trochanteric hip fractures fixation: results of the first 100 Trochanteric implantations.
    Loubignac F; Chabas JF
    Orthop Traumatol Surg Res; 2009 Apr; 95(2):139-44. PubMed ID: 19345659
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Gamma and other cephalocondylic intramedullary nails versus extramedullary implants for extracapsular hip fractures.
    Parker MJ; Handoll HH
    Cochrane Database Syst Rev; 2004; (1):CD000093. PubMed ID: 14973946
    [TBL] [Abstract][Full Text] [Related]  

  • 16. A biomechanical comparison of static versus dynamic lag screw modes for cephalomedullary nails used to fix unstable peritrochanteric fractures.
    Kuzyk PR; Shah S; Zdero R; Olsen M; Waddell JP; Schemitsch EH
    J Trauma Acute Care Surg; 2012 Feb; 72(2):E65-70. PubMed ID: 22439235
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Gamma and other cephalocondylic intramedullary nails versus extramedullary implants for extracapsular hip fractures in adults.
    Parker MJ; Handoll HH
    Cochrane Database Syst Rev; 2010 Sep; (9):CD000093. PubMed ID: 20824825
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Benefit of lag screw placement by a single- or two-screw nailing system in elderly patients with AO/OTA 31-A2 trochanteric fractures.
    Zhao F; Guo L; Wang X; Zhang Y
    J Int Med Res; 2021 Mar; 49(3):3000605211003766. PubMed ID: 33787370
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Integrated dual lag screws versus single lag screw cephalomedullary nail constructs: a meta-analysis and systematic review.
    Onggo JR; Nambiar M; Onggo JD; Ambikaipalan A; Singh PJ; Babazadeh S
    Hip Int; 2022 Jul; 32(4):550-557. PubMed ID: 33566701
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Risk of shortening in operatively treated proximal femur fractures with cephalomedullary nails with dynamically versus statistically locked helical blades.
    Cherian N; Oladeji L; Ohnoutka C; Touhey D; Sauer M; Schweser KA; Kfuri M; Cook JL; Rocca GJD; Crist BD
    Injury; 2023 Feb; 54(2):669-676. PubMed ID: 36539309
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.