These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

139 related articles for article (PubMed ID: 35979971)

  • 1. Comparison of C-MAC and McGrathMAC Videolaryngoscopes for Intubation in Patients with Normal Airway by Donned Anaesthesiologists Using an Intubation Box During COVID-19 Pandemic: A Prospective, Randomized Study.
    Gupta N; Sarma R; Vig S; Kumar V; Gupta A; Mishra S
    Turk J Anaesthesiol Reanim; 2022 Aug; 50(4):255-260. PubMed ID: 35979971
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Comparative efficacy of C-MAC
    Gupta A; Singh P; Gupta N; Kumar Malhotra R; Girdhar KK
    Paediatr Anaesth; 2021 Oct; 31(10):1089-1096. PubMed ID: 34153141
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Comparing the first-attempt tracheal intubation success of the hyperangulated McGrath® X-blade vs the Macintosh-type CMAC videolaryngoscope in patients with cervical immobilization: a two-centre randomized controlled trial.
    Zhang J; Tan LZ; Toh H; Foo CW; Wijeratne S; Hu H; Seet E
    J Clin Monit Comput; 2022 Aug; 36(4):1139-1145. PubMed ID: 34347225
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Randomized controlled trial comparing the McGrath videolaryngoscope with the C-MAC videolaryngoscope in intubating adult patients with potential difficult airways.
    Ng I; Hill AL; Williams DL; Lee K; Segal R
    Br J Anaesth; 2012 Sep; 109(3):439-43. PubMed ID: 22677878
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Comparison of intubation success and glottic visualization using King Vision and C-MAC videolaryngoscopes in patients with cervical spine injuries with cervical immobilization: A randomized clinical trial.
    Shravanalakshmi D; Bidkar PU; Narmadalakshmi K; Lata S; Mishra SK; Adinarayanan S
    Surg Neurol Int; 2017; 8():19. PubMed ID: 28217398
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Comparative Evaluation of McGrath MAC, Truview Video Laryngoscopes and Macintosh Laryngoscope for Endotracheal Intubation in Patients Undergoing Surgery under General Anaesthesia.
    Kaur G; Gupta S; Mehta N; Dhingra JS
    Anesth Essays Res; 2020; 14(1):20-24. PubMed ID: 32843786
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A Comparative Evaluation of 2 Videolaryngoscopes as an Intubation Aid in a Simulated Difficult Airway: A Prospective Randomised Study.
    Kumar A; Taluja A; Saxena B; Dwivedi P
    Turk J Anaesthesiol Reanim; 2022 Oct; 50(5):340-345. PubMed ID: 36301282
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Macintosh Videolaryngoscope for Intubation in the Operating Room: A Comparative Quality Improvement Project.
    De Jong A; Pouzeratte Y; Laplace A; Normanno M; Rollé A; Verzilli D; Perrigault PF; Colson P; Capdevila X; Molinari N; Jaber S
    Anesth Analg; 2021 Feb; 132(2):524-535. PubMed ID: 32739955
    [TBL] [Abstract][Full Text] [Related]  

  • 9. McGrath Series 5 videolaryngoscope vs Airtraq DL videolaryngoscope for double-lumen tube intubation: A randomized trial.
    Wan L; Liao M; Li L; Qian W; Hu R; Chen K; Zhang C; Yao W
    Medicine (Baltimore); 2016 Dec; 95(51):e5739. PubMed ID: 28002347
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Postoperative sore throat and subglottic injury after McGrath® MAC videolaryngoscopic intubation with versus without a stylet in patients with a high Mallampati score: a randomized controlled trial.
    Yoon HK; Lee HC; Oh H; Jun K; Park HP
    BMC Anesthesiol; 2019 Jul; 19(1):137. PubMed ID: 31366325
    [TBL] [Abstract][Full Text] [Related]  

  • 11. [McGRATH MAC Videolaryngoscope: clinical assessment of its performance in 50 surgical patients].
    Negishi Y; Shimada N; Urayama M; Niwa Y; Takeuchi M
    Masui; 2014 Sep; 63(9):1025-8. PubMed ID: 25255665
    [TBL] [Abstract][Full Text] [Related]  

  • 12. McGrath MAC Videolaryngoscope Versus Optiscope Video Stylet for Tracheal Intubation in Patients With Manual Inline Cervical Stabilization: A Randomized Trial.
    Yoon HK; Lee HC; Park JB; Oh H; Park HP
    Anesth Analg; 2020 Apr; 130(4):870-878. PubMed ID: 31567321
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Comparison of the Pentax AirwayScope and McGrath MAC videolaryngoscope for endotracheal intubation in patients with a normal airway.
    Lee J; Kwak HJ; Lee JY; Chang MY; Lee SY; Kim JY
    Medicine (Baltimore); 2017 Nov; 96(46):e8713. PubMed ID: 29145308
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Comparison of three video laryngoscopy devices to direct laryngoscopy for intubating obese patients: a randomized controlled trial.
    Yumul R; Elvir-Lazo OL; White PF; Sloninsky A; Kaplan M; Kariger R; Naruse R; Parker N; Pham C; Zhang X; Wender RH
    J Clin Anesth; 2016 Jun; 31():71-7. PubMed ID: 27185681
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Tracheal intubation with the McGrath MAC X-blade videolaryngoscope in morbidly obese and nonobese patients.
    Arslan Zİ; Yörükoğlu HU
    Turk J Med Sci; 2019 Oct; 49(5):1540-1546. PubMed ID: 31652034
    [TBL] [Abstract][Full Text] [Related]  

  • 16. First pass success of tracheal intubation using the C-MAC PM videolaryngoscope as first-line device in prehospital cardiac arrest compared with other emergencies: An observational study.
    Hossfeld B; Thierbach S; Allgoewer A; Gaessler H; Helm M
    Eur J Anaesthesiol; 2021 Aug; 38(8):806-812. PubMed ID: 32833853
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Effects of head-elevated position on tracheal intubation using a McGrath MAC videolaryngoscope in patients with a simulated difficult airway: a prospective randomized crossover study.
    Chun EH; Chung MH; Kim JE; Kim KM; Lee HS; Son JM; Park J; Jun JH
    BMC Anesthesiol; 2022 May; 22(1):166. PubMed ID: 35637437
    [TBL] [Abstract][Full Text] [Related]  

  • 18. A comparison of the Glidescope® to the McGrath® videolaryngoscope in patients.
    Jeon WJ; Kim KH; Yeom JH; Bang MR; Hong JB; Cho SY
    Korean J Anesthesiol; 2011 Jul; 61(1):19-23. PubMed ID: 21860746
    [TBL] [Abstract][Full Text] [Related]  

  • 19. A comparison of the McGrath® Series 5 videolaryngoscope and Macintosh laryngoscope for double-lumen tracheal tube placement in patients with a good glottic view at direct laryngoscopy.
    Yao WL; Wan L; Xu H; Qian W; Wang XR; Tian YK; Zhang CH
    Anaesthesia; 2015 Jul; 70(7):810-7. PubMed ID: 25721326
    [TBL] [Abstract][Full Text] [Related]  

  • 20. C-MAC videolaryngoscope compared with direct laryngoscopy for rapid sequence intubation in an emergency department: A randomised clinical trial.
    Sulser S; Ubmann D; Schlaepfer M; Brueesch M; Goliasch G; Seifert B; Spahn DR; Ruetzler K
    Eur J Anaesthesiol; 2016 Dec; 33(12):943-948. PubMed ID: 27533711
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.