These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

122 related articles for article (PubMed ID: 3598894)

  • 21. Identification and quantification of ethylene oxide in sterilized medical devices using multiple headspace GC/MS measurement.
    Gimeno P; Auguste ML; Handlos V; Nielsen AM; Schmidt S; Lassu N; Vogel M; Fischer A; Brenier C; Duperray F
    J Pharm Biomed Anal; 2018 Sep; 158():119-127. PubMed ID: 29864694
    [TBL] [Abstract][Full Text] [Related]  

  • 22. A sensitive estimation of residual ethylene glycol in ethylene oxide sterilized medical devices by HPLC with electrospray ionization mass spectrometric detection.
    Hari PR; Naseerali CP; Sreenivasan K
    J Chromatogr B Analyt Technol Biomed Life Sci; 2009 Jan; 877(3):328-32. PubMed ID: 19112050
    [TBL] [Abstract][Full Text] [Related]  

  • 23. The determination of residual ethylene oxide and halogenated hydrocarbon propellants in sterilized plastics.
    Warren B
    J Pharm Pharmacol; 1971 Dec; 23():170S-175S. PubMed ID: 4401453
    [No Abstract]   [Full Text] [Related]  

  • 24. Determination of ethylene oxide in ethoxylated surfactants and demulsifiers by headspace gas chromatography.
    Dahlgran JR; Shingleton CR
    J Assoc Off Anal Chem; 1987; 70(5):796-8. PubMed ID: 3680111
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Determination of residual ethylene oxide in catheters by gas-liquid chromatography.
    Kulkarni RK; Bartak D; Ousterhout DK; Leonard F
    J Biomed Mater Res; 1968 Mar; 2(1):165-71. PubMed ID: 5708003
    [No Abstract]   [Full Text] [Related]  

  • 26. Rapid gas chromatographic determination of ethylene oxide, ethylene chlorohydrin, and ethylene glycol residues in rubber catheters.
    Muzeni RJ
    J Assoc Off Anal Chem; 1985; 68(3):506-8. PubMed ID: 4019375
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Measurement of ethylene oxide and water vapor in powders during sterilization.
    Frieben WR; Robertson JH; Goetz JF; Enzinger RM
    J Parenter Sci Technol; 1983; 37(1):4-6. PubMed ID: 6834215
    [No Abstract]   [Full Text] [Related]  

  • 28. Optimization of a novel headspace-solid-phase microextraction-gas chromatographic method by means of a Doehlert uniform shell design for the analysis of trace level ethylene oxide residuals in sterilized medical devices.
    DiCicco MP; Lang B; Harper TI
    Biomed Chromatogr; 2009 Jun; 23(6):647-57. PubMed ID: 19277966
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Physico-chemical and toxicologo-hygienic aspects of using ethylene oxide for the sterilization of medical appliances. Part I. Sorption and diffusion of ethylene oxide in polymeric materials.
    Lyarskii PP; Likhtman TV; Kareyev NV; Komarkova NI; Gleiberman SE
    J Hyg Epidemiol Microbiol Immunol; 1984; 28(2):119-28. PubMed ID: 6470476
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Ethylene oxide sterilization of bone grafts. Residual gas concentration and fibroblast toxicity.
    Arizono T; Iwamoto Y; Okuyama K; Sugioka Y
    Acta Orthop Scand; 1994 Dec; 65(6):640-2. PubMed ID: 7839851
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Gas chromatographic determination with electron capture detection of residual ethylene oxide in intraocular lenses.
    Kikuchi H; Nakamura A; Tsuji K
    J Assoc Off Anal Chem; 1988; 71(5):1057-62. PubMed ID: 3235402
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Extraction and stability of ethylene oxide residue in medical devices.
    Lucas AD; Stratmeyer ME
    Biomed Instrum Technol; 2008; 42(1):76-9. PubMed ID: 18257644
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Ethylene oxide residues in sterilized medical devices.
    Charlesworth FA
    Food Cosmet Toxicol; 1976 Jan; 14(1):61. PubMed ID: 1254209
    [No Abstract]   [Full Text] [Related]  

  • 34. Chromatographic methods for analysis of ethylene oxide in emissions from stationary sources.
    Margeson JH; Steger JL; Homolya JB
    J Chromatogr Sci; 1990 Apr; 28(4):204-9. PubMed ID: 2079550
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Ethylene oxide sterilization: effect of polymer structure and sterilization conditions on residue levels.
    Gilding DK; Reed AM; Baskett SA
    Biomaterials; 1980 Jul; 1(3):145-8. PubMed ID: 7470566
    [No Abstract]   [Full Text] [Related]  

  • 36. [Evaluation of in Vitro Cytotoxicity Tests for Medical Material Using Hydrogen Peroxide Gas Plasma Sterilization].
    Yao Y; Ding B
    Zhongguo Yi Liao Qi Xie Za Zhi; 2017 Mar; 41(2):144-145. PubMed ID: 29862690
    [TBL] [Abstract][Full Text] [Related]  

  • 37. [Development of the method for determining substances--markers of the hazardous production of advanced oil processing (ethylene oxide, 1,3-butadiene) in the air at the level of reference concentrations].
    Gig Sanit; 2012; (4):78-82. PubMed ID: 23082678
    [TBL] [Abstract][Full Text] [Related]  

  • 38. [Study on sterilization by ethylene oxide gas and the residual gas following the sterilization procedure].
    Hirota T; Morifuji C; Yamada C; Fujiki M; Taguchi M
    Kangogaku Zasshi; 1988 Sep; 52(9):898-901. PubMed ID: 3204793
    [No Abstract]   [Full Text] [Related]  

  • 39. On-line measurement of the gaseous concentration and relative humidity in a 100% ethylene oxide sterilization cycle.
    Yeung AC; Levine IB
    J Parenter Drug Assoc; 1979; 33(3):117-24. PubMed ID: 256992
    [No Abstract]   [Full Text] [Related]  

  • 40. Ethylene Oxide Gas Sterilization of Medical Devices.
    Shintani H
    Biocontrol Sci; 2017; 22(1):1-16. PubMed ID: 28367865
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 7.