These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

154 related articles for article (PubMed ID: 35993231)

  • 21. Two-dimensional measurement misidentifies alignment outliers in total knee arthroplasty: a comparison of two- and three-dimensional measurements.
    Ueyama H; Minoda Y; Sugama R; Ohta Y; Yamamura K; Nakamura S; Takemura S; Nakamura H
    Knee Surg Sports Traumatol Arthrosc; 2019 May; 27(5):1497-1503. PubMed ID: 30284009
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Robot-assisted implantation improves the precision of component position in minimally invasive TKA.
    Kim SM; Park YS; Ha CW; Lim SJ; Moon YW
    Orthopedics; 2012 Sep; 35(9):e1334-9. PubMed ID: 22955398
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Does Component Alignment Affect Patient Reported Outcomes following Bicruciate Retaining Total Knee Arthroplasty? An In Vivo Three-Dimensional Analysis.
    Peng Y; Arauz P; An S; Limmahakhun S; Klemt C; Kwon YM
    J Knee Surg; 2020 Aug; 33(8):798-803. PubMed ID: 31064018
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Intra- and interobserver reliability and agreement in three-dimensional computed tomography measurements of component positions after total knee arthroplasty.
    Yoshino K; Hagiwara S; Nakamura J; Tsukeoka T; Tsuneizumi Y; Ohtori S
    Knee; 2019 Oct; 26(5):1102-1110. PubMed ID: 31340892
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Differences in component and limb alignment between computer-assisted and conventional surgery total knee arthroplasty.
    Huang TW; Peng KT; Huang KC; Lee MS; Hsu RW
    Knee Surg Sports Traumatol Arthrosc; 2014 Dec; 22(12):2954-61. PubMed ID: 25331655
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Accuracy of Bone Resection in MAKO Total Knee Robotic-Assisted Surgery.
    Sires JD; Craik JD; Wilson CJ
    J Knee Surg; 2021 Jun; 34(7):745-748. PubMed ID: 31694057
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Are There Differences in Accuracy or Outcomes Scores Among Navigated, Robotic, Patient-specific Instruments or Standard Cutting Guides in TKA? A Network Meta-analysis.
    Bouché PA; Corsia S; Dechartres A; Resche-Rigon M; Nizard R
    Clin Orthop Relat Res; 2020 Sep; 478(9):2105-2116. PubMed ID: 32530896
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Component placement accuracy in two generations of handheld robotics-assisted knee arthroplasty.
    Sicat CS; Chow JC; Kaper B; Mitra R; Xie J; Schwarzkopf R
    Arch Orthop Trauma Surg; 2021 Dec; 141(12):2059-2067. PubMed ID: 34304279
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Robot-Assisted Total Knee Arthroplasty Does Not Improve Long-Term Clinical and Radiologic Outcomes.
    Jeon SW; Kim KI; Song SJ
    J Arthroplasty; 2019 Aug; 34(8):1656-1661. PubMed ID: 31036450
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Robotic-assisted total knee arthroplasty improved component alignment in the coronal plane compared with navigation-assisted total knee arthroplasty: a comparative study.
    Omichi Y; Hamada D; Wada K; Tamaki Y; Shigekiyo S; Sairyo K
    J Robot Surg; 2023 Dec; 17(6):2831-2839. PubMed ID: 37755679
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Design improvement in patient-specific instrumentation for total knee arthroplasty improved the accuracy of the tibial prosthetic alignment in the coronal and axial planes.
    Yamamura K; Minoda Y; Sugama R; Ohta Y; Nakamura S; Ueyama H; Nakamura H
    Knee Surg Sports Traumatol Arthrosc; 2020 May; 28(5):1560-1567. PubMed ID: 31240377
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Accuracy of different navigation systems for femoral and tibial implantation in total knee arthroplasty: a randomised comparative study.
    Saiki Y; Ojima T; Kabata T; Hayashi S; Tsuchiya H
    Arch Orthop Trauma Surg; 2021 Dec; 141(12):2267-2276. PubMed ID: 34652514
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Revision of partial knee to total knee arthroplasty with use of patient-specific instruments results in acceptable femoral rotation.
    Schotanus MGM; Thijs E; Boonen B; Kerens B; Jong B; Kort NP
    Knee Surg Sports Traumatol Arthrosc; 2018 Jun; 26(6):1656-1661. PubMed ID: 28785788
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Deviations in femoral joint lines using calipered kinematically aligned TKA from virtually planned joint lines are small and do not affect clinical outcomes.
    Nedopil AJ; Howell SM; Hull ML
    Knee Surg Sports Traumatol Arthrosc; 2020 Oct; 28(10):3118-3127. PubMed ID: 31768572
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Two-dimensional planning can result in internal rotation of the femoral component in total knee arthroplasty.
    Okamoto S; Mizu-uchi H; Okazaki K; Hamai S; Tashiro Y; Nakahara H; Iwamoto Y
    Knee Surg Sports Traumatol Arthrosc; 2016 Jan; 24(1):229-35. PubMed ID: 25297705
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Robotic-assisted TKA leads to a better prosthesis alignment and a better joint line restoration as compared to conventional TKA: a prospective randomized controlled trial.
    Vaidya NV; Deshpande AN; Panjwani T; Patil R; Jaysingani T; Patil P
    Knee Surg Sports Traumatol Arthrosc; 2022 Feb; 30(2):621-626. PubMed ID: 33165631
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Preoperative CT-Based Three-Dimensional Templating in Robot-Assisted Total Knee Arthroplasty More Accurately Predicts Implant Sizes than Two-Dimensional Templating.
    Pietrzak JRT; Rowan FE; Kayani B; Donaldson MJ; Huq SS; Haddad FS
    J Knee Surg; 2019 Jul; 32(7):642-648. PubMed ID: 30068010
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Comparison of custom cutting guides based on three-dimensional computerized CT-scan planning and a conventional ancillary system based on two-dimensional planning in total knee arthroplasty: a randomized controlled trial.
    Sariali E; Kajetanek C; Catonné Y
    Int Orthop; 2019 Nov; 43(11):2529-2538. PubMed ID: 31227853
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Conventional or navigated total knee arthroplasty affects sagittal component alignment.
    Sugama R; Minoda Y; Kobayashi A; Iwaki H; Ikebuchi M; Takaoka K; Nakamura H
    Knee Surg Sports Traumatol Arthrosc; 2012 Dec; 20(12):2454-9. PubMed ID: 22261992
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Technical Considerations and Accuracy Improvement of Accelerometer-Based Portable Computer Navigation for Performing Distal Femoral Resection in Total Knee Arthroplasty.
    Fujimoto E; Sasashige Y; Nakata K; Yokota G; Omoto T; Ochi M
    J Arthroplasty; 2017 Jan; 32(1):53-60. PubMed ID: 27365295
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 8.