These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
132 related articles for article (PubMed ID: 35993986)
21. Mechanical Outcomes, Microleakage, and Marginal Accuracy at the Implant-Abutment Interface of Original versus Nonoriginal Implant Abutments: A Systematic Review of In Vitro Studies. Tallarico M; Fiorellini J; Nakajima Y; Omori Y; Takahisa I; Canullo L Biomed Res Int; 2018; 2018():2958982. PubMed ID: 30719437 [TBL] [Abstract][Full Text] [Related]
22. A pilot study of joint stability at the zirconium or titanium abutment/titanium implant interface. Cavusoglu Y; Akça K; Gürbüz R; Cehreli MC Int J Oral Maxillofac Implants; 2014; 29(2):338-43. PubMed ID: 24683559 [TBL] [Abstract][Full Text] [Related]
23. Mechanical strength of stock and custom abutments as original and aftermarket components after thermomechanical aging. Pol CWP; Cune MS; Raghoebar GM; Naves LZ; Meijer HJA Clin Exp Dent Res; 2024 Aug; 10(4):e892. PubMed ID: 39052871 [TBL] [Abstract][Full Text] [Related]
24. Bending moments and types of failure of zirconia and titanium abutments with internal implant-abutment connections: a laboratory study. Leutert CR; Stawarczyk B; Truninger TC; Hämmerle CH; Sailer I Int J Oral Maxillofac Implants; 2012; 27(3):505-12. PubMed ID: 22616042 [TBL] [Abstract][Full Text] [Related]
25. Evaluation of the fit of CAD/CAM abutments. Hamilton A; Judge RB; Palamara JE; Evans C Int J Prosthodont; 2013; 26(4):370-80. PubMed ID: 23837169 [TBL] [Abstract][Full Text] [Related]
26. Leakage evaluation of original and compatible implant-abutment connections: In vitro study using Rhodamine B. Berberi A; Tehini G; Rifai K; Bou Nasser Eddine F; Badran B; Akl H J Dent Biomech; 2014; 5():1758736014547143. PubMed ID: 25342984 [TBL] [Abstract][Full Text] [Related]
27. Effects of different abutment material and surgical insertion torque on the marginal adaptation of an internal conical interface: an in vitro study. Farronato D; Pieroni S; Mangano FG; Briguglio F; Re D J Prosthodont Res; 2014 Oct; 58(4):230-6. PubMed ID: 24986370 [TBL] [Abstract][Full Text] [Related]
28. Implants with original and non-original abutment connections. Gigandet M; Bigolin G; Faoro F; Bürgin W; Brägger U Clin Implant Dent Relat Res; 2014 Apr; 16(2):303-11. PubMed ID: 22804848 [TBL] [Abstract][Full Text] [Related]
29. Wear at the titanium-titanium and the titanium-zirconia implant-abutment interface: a comparative in vitro study. Stimmelmayr M; Edelhoff D; Güth JF; Erdelt K; Happe A; Beuer F Dent Mater; 2012 Dec; 28(12):1215-20. PubMed ID: 23021964 [TBL] [Abstract][Full Text] [Related]
30. Fatigue survival and failure resistance of titanium versus zirconia implant abutments with various connection designs. Sen N; Us YO J Prosthet Dent; 2019 Sep; 122(3):315.e1-315.e7. PubMed ID: 31326150 [TBL] [Abstract][Full Text] [Related]
31. Influence of the Use of Transepithelial Abutments vs. Titanium Base Abutments on Microgap Formation at the Dental Implant-Abutment Interface: An In Vitro Study. Cascos R; Celemín-Viñuela A; Mory-Rubiños N; Gómez-Polo C; Ortega R; Agustín-Panadero R; Gómez-Polo M Materials (Basel); 2023 Oct; 16(19):. PubMed ID: 37834669 [TBL] [Abstract][Full Text] [Related]
32. Load fatigue performance of conical implant-abutment connections. Seetoh YL; Tan KB; Chua EK; Quek HC; Nicholls JI Int J Oral Maxillofac Implants; 2011; 26(4):797-806. PubMed ID: 21841990 [TBL] [Abstract][Full Text] [Related]
33. Influence of the size of the microgap on crestal bone changes around titanium implants. A histometric evaluation of unloaded non-submerged implants in the canine mandible. Hermann JS; Schoolfield JD; Schenk RK; Buser D; Cochran DL J Periodontol; 2001 Oct; 72(10):1372-83. PubMed ID: 11699479 [TBL] [Abstract][Full Text] [Related]
34. In vitro assessment of three types of zirconia implant abutments under static load. Kim JS; Raigrodski AJ; Flinn BD; Rubenstein JE; Chung KH; Mancl LA J Prosthet Dent; 2013 Apr; 109(4):255-63. PubMed ID: 23566607 [TBL] [Abstract][Full Text] [Related]
35. Wear at the titanium-zirconia implant-abutment interface: a pilot study. Klotz MW; Taylor TD; Goldberg AJ Int J Oral Maxillofac Implants; 2011; 26(5):970-5. PubMed ID: 22010078 [TBL] [Abstract][Full Text] [Related]
36. Mechanical stability of fully personalized, abutment-free zirconia implant crowns on a novel implant-crown interface. Hjerppe J; Jung RE; Hämmerle CH; Özcan M; Mühlemann S J Dent; 2022 Jun; 121():104121. PubMed ID: 35395344 [TBL] [Abstract][Full Text] [Related]
37. Stiffness, strength, and failure modes of implant-supported monolithic lithium disilicate crowns: influence of titanium and zirconia abutments. Joda T; Bürki A; Bethge S; Brägger U; Zysset P Int J Oral Maxillofac Implants; 2015; 30(6):1272-9. PubMed ID: 26574852 [TBL] [Abstract][Full Text] [Related]
38. Vertical Misfit of Single-Implant Abutments Made from Different Materials Under Cyclic Loading. Butignon LE; de Almeida Basílio M; Santo JS; Arioli Filho JN Int J Oral Maxillofac Implants; 2016; 31(5):1017-22. PubMed ID: 27632255 [TBL] [Abstract][Full Text] [Related]
39. In vitro analysis of prosthetic abutment and angulable frictional implant interface adaptation: Mechanical and microbiological study. de Aguiar Vilela Júnior R; Aranha LC; Elias CN; Martinez EF J Biomech; 2021 Nov; 128():110733. PubMed ID: 34530293 [TBL] [Abstract][Full Text] [Related]
40. Internal and Marginal Fit and Fracture Strength of Narrow Diameter Dental Implant-Abutment Assembly. Ruschel GH; Bacchi A; Moris ICM; Poole SF; Ribeiro RF; Gomes ÉA Braz Dent J; 2020; 31(2):127-134. PubMed ID: 32556011 [TBL] [Abstract][Full Text] [Related] [Previous] [Next] [New Search]