285 related articles for article (PubMed ID: 35996060)
1. Plating versus elastic stable intramedullary nailing for displaced pediatric midshaft clavicular fractures.
Hong P; Liu R; Rai S; Ze R; Tang X; Li J
J Orthop Traumatol; 2022 Aug; 23(1):42. PubMed ID: 35996060
[TBL] [Abstract][Full Text] [Related]
2. [Surgical Treatment of Clavicle Midshaft Fractures - Prospective Randomized Trial].
Šimek J; Šmejkal K; Frank M; Hyšpler R; Dědek T; Páral J
Acta Chir Orthop Traumatol Cech; 2020; 87(2):101-107. PubMed ID: 32396510
[TBL] [Abstract][Full Text] [Related]
3. Plate fixation
Fuglesang HFS; Flugsrud GB; Randsborg PH; Oord P; Benth JŠ; Utvåg SE
Bone Joint J; 2017 Aug; 99-B(8):1095-1101. PubMed ID: 28768788
[TBL] [Abstract][Full Text] [Related]
4. [Intramedullary stabilisation of displaced midshaft clavicular fractures: does the fracture pattern (simple vs. complex) influence the anatomic and functional result].
Langenhan R; Reimers N; Probst A
Z Orthop Unfall; 2014 Dec; 152(6):588-95. PubMed ID: 25531520
[TBL] [Abstract][Full Text] [Related]
5. Complications after plate fixation and elastic stable intramedullary nailing of dislocated midshaft clavicle fractures: a retrospective comparison.
Wijdicks FJ; Houwert M; Dijkgraaf M; de Lange D; Oosterhuis K; Clevers G; Verleisdonk EJ
Int Orthop; 2012 Oct; 36(10):2139-45. PubMed ID: 22847116
[TBL] [Abstract][Full Text] [Related]
6. Long-term Functional Outcomes and Complications in Operative Versus Nonoperative Treatment for Displaced Midshaft Clavicle Fractures in Adolescents: A Retrospective Comparative Study.
Riiser MO; Molund M
J Pediatr Orthop; 2021 May-Jun 01; 41(5):279-283. PubMed ID: 33606445
[TBL] [Abstract][Full Text] [Related]
7. High Irritation and Removal Rates After Plate or Nail Fixation in Patients With Displaced Midshaft Clavicle Fractures.
Hulsmans MH; van Heijl M; Houwert RM; Hammacher ER; Meylaerts SA; Verhofstad MH; Dijkgraaf MG; Verleisdonk EJ
Clin Orthop Relat Res; 2017 Feb; 475(2):532-539. PubMed ID: 27830484
[TBL] [Abstract][Full Text] [Related]
8. Surgical fixation of displaced midshaft clavicle fractures: elastic intramedullary nailing versus precontoured plating.
Narsaria N; Singh AK; Arun GR; Seth RR
J Orthop Traumatol; 2014 Sep; 15(3):165-71. PubMed ID: 24859367
[TBL] [Abstract][Full Text] [Related]
9. Elastic stable intramedullary nailing is best for mid-shaft clavicular fractures without comminution: results in 60 patients.
Smekal V; Irenberger A; Attal RE; Oberladstaetter J; Krappinger D; Kralinger F
Injury; 2011 Apr; 42(4):324-9. PubMed ID: 20394920
[TBL] [Abstract][Full Text] [Related]
10. Elastic stable intramedullary nailing versus nonoperative treatment of displaced midshaft clavicular fractures-a randomized, controlled, clinical trial.
Smekal V; Irenberger A; Struve P; Wambacher M; Krappinger D; Kralinger FS
J Orthop Trauma; 2009 Feb; 23(2):106-12. PubMed ID: 19169102
[TBL] [Abstract][Full Text] [Related]
11. Surgical complications following ESIN for clavicular mid-shaft fractures do not limit functional or patient-perceived outcome.
Lechler P; Sturm S; Boese CK; Bockmann B; Schwarting T; Ruchholtz S; Lahner M; Frink M
Injury; 2016 Apr; 47(4):899-903. PubMed ID: 26674161
[TBL] [Abstract][Full Text] [Related]
12. Plate versus intramedullary fixation of two-part and multifragmentary displaced midshaft clavicle fractures - a long-term analysis.
Chan G; Korac Z; Miletic M; Vidovic D; Phadnis J; Bakota B
Injury; 2017 Nov; 48 Suppl 5():S21-S26. PubMed ID: 29122117
[TBL] [Abstract][Full Text] [Related]
13. Flexible intramedullary nailing for stabilization of displaced midshaft clavicle fractures: technique and results in 87 patients.
Kettler M; Schieker M; Braunstein V; König M; Mutschler W
Acta Orthop; 2007 Jun; 78(3):424-9. PubMed ID: 17611859
[TBL] [Abstract][Full Text] [Related]
14. Operative treatment of dislocated midshaft clavicular fractures: plate or intramedullary nail fixation? A randomized controlled trial.
van der Meijden OA; Houwert RM; Hulsmans M; Wijdicks FJ; Dijkgraaf MG; Meylaerts SA; Hammacher ER; Verhofstad MH; Verleisdonk EJ
J Bone Joint Surg Am; 2015 Apr; 97(8):613-9. PubMed ID: 25878304
[TBL] [Abstract][Full Text] [Related]
15. Single, superiorly placed reconstruction plate compared with flexible intramedullary nailing for midshaft clavicular fractures: a prospective, randomized controlled trial.
Andrade-Silva FB; Kojima KE; Joeris A; Santos Silva J; Mattar R
J Bone Joint Surg Am; 2015 Apr; 97(8):620-6. PubMed ID: 25878305
[TBL] [Abstract][Full Text] [Related]
16. Intramedullary nailing of clavicular midshaft fractures in adults using titanium elastic nail.
Chen QY; Kou DQ; Cheng XJ; Zhang W; Wang W; Lin ZQ; Cheng SW; Shen Y; Ying XZ; Peng L; Lv CZ
Chin J Traumatol; 2011; 14(5):269-76. PubMed ID: 22118480
[TBL] [Abstract][Full Text] [Related]
17. Plate fixation versus intramedullary nail or Knowles pin fixation for displaced midshaft clavicle fractures: A meta-analysis of randomized controlled trials.
Li L; Yang X; Xing F; Jiang J; Tang X
Medicine (Baltimore); 2020 Sep; 99(39):e22284. PubMed ID: 32991430
[TBL] [Abstract][Full Text] [Related]
18. Minimally invasive intramedullary nailing of midshaft clavicular fractures using titanium elastic nails.
Mueller M; Rangger C; Striepens N; Burger C
J Trauma; 2008 Jun; 64(6):1528-34. PubMed ID: 18545118
[TBL] [Abstract][Full Text] [Related]
19. End cap versus no end cap in intramedullary nailing for displaced midshaft clavicle fractures: influence on implant-related irritation.
Frima H; Hulsmans MHJ; Houwert RM; Ahmed Ali U; Verleisdonk EJMM; Sommer C; van Heijl M
Eur J Trauma Emerg Surg; 2018 Feb; 44(1):119-124. PubMed ID: 28314896
[TBL] [Abstract][Full Text] [Related]
20. Distal third femoral shaft fractures in school-aged children: A comparative study of elastic stable intramedullary nail and external fixator.
Li J; Rai S; Ze R; Tang X; Liu R; Hong P
Medicine (Baltimore); 2020 Jul; 99(27):e21053. PubMed ID: 32629731
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]