These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

196 related articles for article (PubMed ID: 35997508)

  • 1. In vitro effect of different implant decontamination methods in three intraosseous defect configurations.
    Luengo F; Sanz-Esporrín J; Noguerol F; Sanz-Martín I; Sanz-Sánchez I; Sanz M
    Clin Oral Implants Res; 2022 Nov; 33(11):1087-1097. PubMed ID: 35997508
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Significance of implant design on the efficacy of different peri-implantitis decontamination protocols.
    Sanz-Martín I; Paeng K; Park H; Cha JK; Jung UW; Sanz M
    Clin Oral Investig; 2021 Jun; 25(6):3589-3597. PubMed ID: 33170374
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Cleaning effects of decontamination methods on clinically failed TiUnite implants and their impacts on surface roughness and chemistry: An in vitro pilot study.
    Qian Y; Tong Z; Cai B; Zhu W; Si M
    Int J Oral Implantol (Berl); 2022 May; 15(2):149-165. PubMed ID: 35546724
    [TBL] [Abstract][Full Text] [Related]  

  • 4. In vitro surgical and non-surgical air-polishing efficacy for implant surface decontamination in three different defect configurations.
    Tuchscheerer V; Eickholz P; Dannewitz B; Ratka C; Zuhr O; Petsos H
    Clin Oral Investig; 2021 Apr; 25(4):1743-1754. PubMed ID: 32813077
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Cleaning effectiveness of implant prophylaxis instruments.
    Schmage P; Kahili F; Nergiz I; Scorziello TM; Platzer U; Pfeiffer P
    Int J Oral Maxillofac Implants; 2014; 29(2):331-7. PubMed ID: 24683558
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Cleaning potential of different air abrasive powders and their impact on implant surface roughness.
    Matsubara VH; Leong BW; Leong MJL; Lawrence Z; Becker T; Quaranta A
    Clin Implant Dent Relat Res; 2020 Feb; 22(1):96-104. PubMed ID: 31837107
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Efficacy of air-polishing devices without removal of implant-supported full-arch prostheses.
    Menini M; Delucchi F; Bagnasco F; Pera F; Di Tullio N; Pesce P
    Int J Oral Implantol (Berl); 2021 Nov; 14(4):401-416. PubMed ID: 34726849
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Comparison between four different implant surface debridement methods: an in-vitro experimental study.
    Mensi M; Viviani L; Agosti R; Scotti E; Garzetti G; Calza S
    Minerva Stomatol; 2020 Oct; 69(5):286-294. PubMed ID: 33174712
    [TBL] [Abstract][Full Text] [Related]  

  • 9. In vitro cleaning potential of three different implant debridement methods.
    Sahrmann P; Ronay V; Hofer D; Attin T; Jung RE; Schmidlin PR
    Clin Oral Implants Res; 2015 Mar; 26(3):314-9. PubMed ID: 24373056
    [TBL] [Abstract][Full Text] [Related]  

  • 10. The efficacy of different implant surface decontamination methods using spectrophotometric analysis: an
    Giffi R; Pietropaoli D; Mancini L; Tarallo F; Sahrmann P; Marchetti E
    J Periodontal Implant Sci; 2023 Aug; 53(4):295-305. PubMed ID: 36731864
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Changes in the surface topography and element proportion of clinically failed SLA implants after in vitro debridement by different methods.
    Tong Z; Fu R; Zhu W; Shi J; Yu M; Si M
    Clin Oral Implants Res; 2021 Mar; 32(3):263-273. PubMed ID: 33314381
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Cleaning potential of glycine air-flow application in an in vitro peri-implantitis model.
    Sahrmann P; Ronay V; Sener B; Jung RE; Attin T; Schmidlin PR
    Clin Oral Implants Res; 2013 Jun; 24(6):666-70. PubMed ID: 22409152
    [TBL] [Abstract][Full Text] [Related]  

  • 13. In vitro efficacy of three different implant surface decontamination methods in three different defect configurations.
    Keim D; Nickles K; Dannewitz B; Ratka C; Eickholz P; Petsos H
    Clin Oral Implants Res; 2019 Jun; 30(6):550-558. PubMed ID: 31009116
    [TBL] [Abstract][Full Text] [Related]  

  • 14. In Vitro Efficacy of Three Different Nonsurgical Implant Surface Decontamination Methods in Three Different Defect Configurations.
    Iatrou P; Chamilos C; Nickles K; Ratka C; Eickholz P; Petsos H
    Int J Oral Maxillofac Implants; 2021; 36(2):271-280. PubMed ID: 33909716
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Surface decontamination of explanted peri-implantitis-affected implants.
    Ichioka Y; Derks J; Larsson L; Berglundh T
    J Clin Periodontol; 2023 Aug; 50(8):1113-1122. PubMed ID: 37271864
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Antimicrobial efficiency and cytocompatibility of different decontamination methods on titanium and zirconium surfaces.
    Stein JM; Conrads G; Abdelbary MMH; Yekta-Michael SS; Buttler P; Glock J; Sadvandi G; Kaufmann R; Apel C
    Clin Oral Implants Res; 2023 Jan; 34(1):20-32. PubMed ID: 36259118
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Anatomical three-dimensional model with peri-implant defect for in vitro assessment of dental implant decontamination.
    Khan SN; Koldsland OC; Tiainen H; Hjortsjö C
    Clin Exp Dent Res; 2024 Feb; 10(1):e841. PubMed ID: 38345509
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Decontamination of biofilm-contaminated implant surfaces: An in vitro evaluation.
    Ichioka Y; Virto L; Nuevo P; Gamonal JD; Derks J; Larsson L; Sanz M; Berglundh T
    Clin Oral Implants Res; 2023 Oct; 34(10):1058-1072. PubMed ID: 37469250
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Comparison of decontamination efficacy of two electrolyte cleaning methods to diode laser, plasma, and air-abrasive devices.
    Zipprich H; Weigl P; Di Gianfilippo R; Steigmann L; Henrich D; Wang HL; Schlee M; Ratka C
    Clin Oral Investig; 2022 Jun; 26(6):4549-4558. PubMed ID: 35322316
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Quantity and Size of Titanium Particles Released from Different Mechanical Decontamination Procedures on Titanium Discs: An In Vitro Study.
    Kao A; Tawse-Smith A; Ma S; Duncan WJ; Reid M; Atieh MA
    Dent J (Basel); 2024 Apr; 12(5):. PubMed ID: 38786521
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.