These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

122 related articles for article (PubMed ID: 36002547)

  • 1. Influence of capillary tube length on the performance of domestic refrigerator with eco-friendly refrigerant R152a.
    Baskaran A; Manikandan N; Jule L; Nagaprasad N; Saka A; Badassa B; Ramaswamy K; Seenivasan V
    Sci Rep; 2022 Aug; 12(1):14460. PubMed ID: 36002547
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Energy-economy-environment assessments of refrigerants R152a and R134a in a vapor compression refrigeration system using a variable displacement oil-free linear compressor.
    Fang X; Chiong MC; Jiang X; Yu LJ; Chen X; Muhieldeen MW; Al-Talib AAM; Lim WH; Wong KY
    Environ Sci Pollut Res Int; 2023 Sep; 30(45):101223-101233. PubMed ID: 37648923
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Theoretical performance studies on environment friendly refrigerants used in refrigeration units.
    Kumma N; Seethala GS; Bhagat Y; Sarath S; Kruthiventi SSH
    Environ Sci Pollut Res Int; 2023 May; 30(22):63065-63083. PubMed ID: 36949375
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Performance of a domestic refrigerator in varying ambient temperatures, concentrations of TiO
    Adelekan DS; Ohunakin OS; Oladeinde MH; Jatinder G; Atiba OE; Nkiko MO; Atayero AA
    Heliyon; 2021 Feb; 7(2):e06156. PubMed ID: 33659731
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Application of Refrigerant Cooling in a Battery Thermal Management System under High Temperature Conditions: A Review.
    Kang Y; Hu Y; Zhang C; Yang K; Zhang Q
    ACS Omega; 2024 Jun; 9(24):25591-25609. PubMed ID: 38911816
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Effects of regenerator geometry on pulse tube refrigerator performance.
    Lewis M; Kuriyama T; Xiao JH; Radebaugh R
    Adv Cryog Eng; 1998; 43 Pt B():1999-2005. PubMed ID: 11543212
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Design and construction of an integrated tetrafluoroethane (R134a) refrigerator-waste heat recovery dryer for fabric drying in tropical regions.
    Onyeocha EI; Nwaigwe KN; Ogueke NV; Anyanwu EE
    Heliyon; 2020 Sep; 6(9):e04838. PubMed ID: 32939418
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Numerical Investigation of Miniature Ejector Refrigeration System Embedded with a Capillary Pump Loop.
    Dong JM; Song H; Yu MQ; Wang WN; Pan XX
    Micromachines (Basel); 2017 Jul; 8(8):. PubMed ID: 30400426
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Variable refrigerant flow cooling assessment in humid environment using different refrigerants.
    Saab R; Al Quabeh H; Hassan Ali MI
    J Environ Manage; 2018 Oct; 224():243-251. PubMed ID: 30055457
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Effect of dilutant concentration on the performance of environment-friendly mixed refrigerants used in domestic refrigerators.
    Kumma N; Kruthiventi SSH
    Environ Sci Pollut Res Int; 2022 Oct; 29(47):71988-72000. PubMed ID: 35606588
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Performance of hydrocarbon refrigerants in a refrigerator with liquid line magnet and CNT nano-lubricant.
    Adelekan DS; Ohunakin OS; Oseahon OI; Nekabari FN; Nkiko MO; Odunfa MK
    Heliyon; 2023 Oct; 9(10):e20832. PubMed ID: 37876452
    [TBL] [Abstract][Full Text] [Related]  

  • 12. An in vitro study of magnetic particle targeting in small blood vessels.
    Udrea LE; Strachan NJ; Bădescu V; Rotariu O
    Phys Med Biol; 2006 Oct; 51(19):4869-81. PubMed ID: 16985276
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Influence of Heat Exchanger Design on the Thermal Performance of a Domestic Wine Cooler Driven by a Magnetic Refrigeration System.
    Peixer GF; Dutra SL; Calomeno RS; Sá NM; Lang GB; Lozano JA; Barbosa JR
    An Acad Bras Cienc; 2022; 94(1):e20200563. PubMed ID: 35107515
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Improving the performance of air conditioning unit by using a hybrid technique.
    Ameen KA; Abdulrasool Hasan H; Al-Dulaimi MJ; Abed AM; Al-Qrimli HF
    MethodsX; 2022; 9():101620. PubMed ID: 35116227
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Manipulating Pore Topology and Functionality to Promote Fluorocarbon-Based Adsorption Cooling.
    Barpaga D; Zheng J; McGrail BP; Motkuri RK
    Acc Chem Res; 2022 Mar; 55(5):649-659. PubMed ID: 34958192
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Performance comparison of ejectors in ejector-based refrigeration cycles with R1234yf, R1234ze(E) and R134a.
    Li S; Liu Y; Liu Y; Zhang J
    Environ Sci Pollut Res Int; 2021 Oct; 28(40):57166-57182. PubMed ID: 34089158
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Exergy and Exergoeconomic Analysis of a Cogeneration Hybrid Solar Organic Rankine Cycle with Ejector.
    Tashtoush B; Morosuk T; Chudasama J
    Entropy (Basel); 2020 Jun; 22(6):. PubMed ID: 33286476
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Limiting Performance of the Ejector Refrigeration Cycle with Pure Working Fluids.
    Fu J; Liu Z; Yang X; Jin S; Ye J
    Entropy (Basel); 2023 Jan; 25(2):. PubMed ID: 36832590
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Performance of Air-Conditioning System with Different Nanoparticle Composition Ratio of Hybrid Nanolubricant.
    Zawawi NNM; Azmi WH; Ghazali MF; Ali HM
    Micromachines (Basel); 2022 Oct; 13(11):. PubMed ID: 36363892
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Experimental investigation of a thermoacoustic-Stirling refrigerator driven by a thermoacoustic-Stirling heat engine.
    Luo EC; Dai W; Zhang Y; Ling H
    Ultrasonics; 2006 Dec; 44 Suppl 1():e1531-3. PubMed ID: 16979679
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.