These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

115 related articles for article (PubMed ID: 3600596)

  • 41. Elasticity and compliance of canine femoral and jugular vein segments.
    Baird RN; Abbott WM
    Am J Physiol; 1977 Jul; 233(1):H15-21. PubMed ID: 879331
    [TBL] [Abstract][Full Text] [Related]  

  • 42. Comparison between mechanical properties of human saphenous vein and umbilical vein.
    Hamedani BA; Navidbakhsh M; Tafti HA
    Biomed Eng Online; 2012 Aug; 11():59. PubMed ID: 22917177
    [TBL] [Abstract][Full Text] [Related]  

  • 43. Endothelial seeding of compliant polyurethane vascular graft material.
    Stansby G; Berwanger C; Shukla N; Schmitz-Rixen T; Hamilton G
    Br J Surg; 1994 Sep; 81(9):1286-9. PubMed ID: 7953388
    [TBL] [Abstract][Full Text] [Related]  

  • 44. Seeding endothelium onto canine arterial prostheses. The effects of graft design.
    Herring M; Gardner A; Glover J
    Arch Surg; 1979 Jun; 114(6):679-82. PubMed ID: 156532
    [TBL] [Abstract][Full Text] [Related]  

  • 45. Characterization in vitro of the biomechanical properties of anastomosed host artery-graft combinations.
    Rodgers VG; Teodori MF; Brant AM; Borovetz HS
    J Vasc Surg; 1986 Oct; 4(4):396-402. PubMed ID: 3761485
    [TBL] [Abstract][Full Text] [Related]  

  • 46. Bacterial cellulose as a potential vascular graft: Mechanical characterization and constitutive model development.
    Zahedmanesh H; Mackle JN; Sellborn A; Drotz K; Bodin A; Gatenholm P; Lally C
    J Biomed Mater Res B Appl Biomater; 2011 Apr; 97(1):105-13. PubMed ID: 21290588
    [TBL] [Abstract][Full Text] [Related]  

  • 47. Preservation of compliance in a small diameter microporous, silicone rubber vascular prosthesis.
    White RA; Klein SR; Shors EC
    J Cardiovasc Surg (Torino); 1987; 28(5):485-90. PubMed ID: 3654733
    [TBL] [Abstract][Full Text] [Related]  

  • 48. Comparative in vitro evaluations of vascular graft compliance during dynamic loading.
    Igo SR; Meador JW; Frazier OH
    ASAIO Trans; 1988; 34(3):785-8. PubMed ID: 3196599
    [TBL] [Abstract][Full Text] [Related]  

  • 49. In vitro C5a generation by synthetic vascular prostheses: implications for graft incorporation in vivo.
    Sindhi R
    Biomater Med Devices Artif Organs; 1986; 14(3-4):249-55. PubMed ID: 2949783
    [TBL] [Abstract][Full Text] [Related]  

  • 50. Mechanical issues in vascular grafting: a review.
    Brossollet LJ
    Int J Artif Organs; 1992 Oct; 15(10):579-84. PubMed ID: 1428204
    [TBL] [Abstract][Full Text] [Related]  

  • 51. Compliance, elastic modulus, and burst pressure of small-intestine submucosa (SIS), small-diameter vascular grafts.
    Roeder R; Wolfe J; Lianakis N; Hinson T; Geddes LA; Obermiller J
    J Biomed Mater Res; 1999 Oct; 47(1):65-70. PubMed ID: 10400882
    [TBL] [Abstract][Full Text] [Related]  

  • 52. A new device for the measurement of the arterial compliance using implantable sensors. Description and first experimental application.
    Welz A; Murrmann G; Hammer C; Stegner U
    Eur Surg Res; 1993; 25(4):245-53. PubMed ID: 8330642
    [TBL] [Abstract][Full Text] [Related]  

  • 53. Compliant design of artificial graft: compliance determination by new digital X-ray imaging system-based method.
    Sonoda H; Urayama S; Takamizawa K; Nakayama Y; Uyama C; Yasui H; Matsuda T
    J Biomed Mater Res; 2002 Apr; 60(1):191-5. PubMed ID: 11835175
    [TBL] [Abstract][Full Text] [Related]  

  • 54. The mechanical properties of glutaraldehyde stabilized human umbilical vein measured in vivo.
    Chapman BL; Charlesworth D
    Br J Surg; 1983 Sep; 70(9):530-1. PubMed ID: 6616156
    [TBL] [Abstract][Full Text] [Related]  

  • 55. [Study on the application of EPTFE (expanded polytetrafluoroethylene) in the field of surgery].
    Matsumoto H
    Nihon Geka Gakkai Zasshi; 1984 Sep; 85(9):893-7. PubMed ID: 6503994
    [TBL] [Abstract][Full Text] [Related]  

  • 56. Electrospun vascular grafts with improved compliance matching to native vessels.
    Nezarati RM; Eifert MB; Dempsey DK; Cosgriff-Hernandez E
    J Biomed Mater Res B Appl Biomater; 2015 Feb; 103(2):313-23. PubMed ID: 24846218
    [TBL] [Abstract][Full Text] [Related]  

  • 57. Thermo-mechanical analysis of a compliant poly(carbonate-urea)urethane after exposure to hydrolytic, oxidative, peroxidative and biological solutions.
    Salacinski HJ; Odlyha M; Hamilton G; Seifalian AM
    Biomaterials; 2002 May; 23(10):2231-40. PubMed ID: 11962664
    [TBL] [Abstract][Full Text] [Related]  

  • 58. The influence of textile vascular prosthesis crimping on graft longitudinal elasticity and flexibility.
    Hajjaji R; Abdessalem SB; Ganghoffer JF
    J Mech Behav Biomed Mater; 2012 Dec; 16():73-80. PubMed ID: 23159512
    [TBL] [Abstract][Full Text] [Related]  

  • 59. Comparison of Hemodynamic Energy between Expanded Polytetrafluoroethylene and Dacron Artificial Vessels.
    Lim J; Won JY; Ahn CB; Kim J; Kim HJ; Jung JS
    J Chest Surg; 2021 Apr; 54(2):81-87. PubMed ID: 33767024
    [TBL] [Abstract][Full Text] [Related]  

  • 60. Fabrication of Nanocomposites with High Elasticity and Strength for the Load-Bearing Layer of Small-Diameter Vascular Grafts.
    Zizhou R; Khoshmanesh K; Wang X; Houshyar S
    ACS Appl Mater Interfaces; 2023 Jul; 15(29):35411-35421. PubMed ID: 37436140
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 6.