342 related articles for article (PubMed ID: 36017756)
1. Open Reduction and Internal Fixation by Volar Locking Plates and the "Poking Reduction" Technique in Distal Radius Fractures with Displaced Dorsal Ulnar Fragments: A Retrospective Study.
Zhang L; Wang M; Liu Z; Wang Y; Sun Y; Zhu Z; Wang X; Liu F; Cui Y
Orthop Surg; 2022 Oct; 14(10):2489-2498. PubMed ID: 36017756
[TBL] [Abstract][Full Text] [Related]
2. Size and fixation options of dorsoulnar fragments in distal radius fractures.
Ji JQ; Zhang X; Cai T; Chen K; Qian JK; Yuan F; Fan J
Injury; 2024 Jun; 55(6):111513. PubMed ID: 38615576
[TBL] [Abstract][Full Text] [Related]
3. Is it really necessary to restore radial anatomic parameters after distal radius fractures?
Dario P; Matteo G; Carolina C; Marco G; Cristina D; Daniele F; Andrea F
Injury; 2014 Dec; 45 Suppl 6():S21-6. PubMed ID: 25457314
[TBL] [Abstract][Full Text] [Related]
4. Comparison between Carbon-Peek volar locking plates and titanium volar locking plates in the treatment of distal radius fractures.
Perugia D; Guzzini M; Mazza D; Iorio C; Civitenga C; Ferretti A
Injury; 2017 Oct; 48 Suppl 3():S24-S29. PubMed ID: 29025605
[TBL] [Abstract][Full Text] [Related]
5. [Operative strategy and clinical results of complex four part distal radius fractures by combined palmar and dorsal internal fixation].
Liu T; Bao FL; Kang SJ; Jiang T; Huang DS; Gao W; Geng LJ; Hu YM
Zhonghua Wai Ke Za Zhi; 2018 Mar; 56(3):183-188. PubMed ID: 29534411
[No Abstract] [Full Text] [Related]
6. Dorsal and volar 2.4-mm titanium locking plate fixation for AO type C3 dorsally comminuted distal radius fractures.
Chou YC; Chen AC; Chen CY; Hsu YH; Wu CC
J Hand Surg Am; 2011 Jun; 36(6):974-81. PubMed ID: 21549526
[TBL] [Abstract][Full Text] [Related]
7. [Plate Osteosynthesis of Distal Ulna Fractures with Associated Distal Radius Fractures Treated by Open Reduction and Internal Fixation. Short-Term Functional and Radiographic Results].
Meluzinová P; Kopp L; Dráč P; Edelmann K; Obruba P
Acta Chir Orthop Traumatol Cech; 2015; 82(5):369-76. PubMed ID: 26516956
[TBL] [Abstract][Full Text] [Related]
8. Prospective study of comminuted articular distal radius fractures stabilized by volar plating in the elderly.
Martinez-Mendez D; Lizaur-Utrilla A; de Juan-Herrero J
Int Orthop; 2018 Sep; 42(9):2243-2248. PubMed ID: 29626236
[TBL] [Abstract][Full Text] [Related]
9. Corrective Osteotomy with Volar and Dorsal Fixation for Malunion of Intra-Articular Fracture of the Distal Radius: A Retrospective Study.
Zhang H; Zhu Y; Fu F; Gou L; Zhu Y; Zhang Z; Zhou C; Yao S; Yue M; Li X; Tong P; Ruan H; Wu C
Orthop Surg; 2022 Aug; 14(8):1751-1758. PubMed ID: 35866348
[TBL] [Abstract][Full Text] [Related]
10. Dorsal plating versus volar plating with limited dorsal open reduction in the management of AO type C3 distal radius fractures with impacted articular fragments: A retrospective comparative study.
Lee JH; Ahn JT; Baek JH
Acta Orthop Traumatol Turc; 2022 Jan; 56(1):42-47. PubMed ID: 35234128
[TBL] [Abstract][Full Text] [Related]
11. Loss of radial height in extra-articular distal radial fracture following volar locking plate fixation.
Cheng MF; Chiang CC; Lin CC; Chang MC; Wang CS
Orthop Traumatol Surg Res; 2021 Sep; 107(5):102842. PubMed ID: 33548565
[TBL] [Abstract][Full Text] [Related]
12. Surgical treatment of unstable distal radius fractures with volar locking plates.
Murakami K; Abe Y; Takahashi K
J Orthop Sci; 2007 Mar; 12(2):134-40. PubMed ID: 17393268
[TBL] [Abstract][Full Text] [Related]
13. The Effect of Displaced Dorsal Rim Fragment in a Distal Radius Fracture.
Kim JK; Yun YH; Kim DJ
J Wrist Surg; 2016 Mar; 5(1):31-5. PubMed ID: 26855833
[TBL] [Abstract][Full Text] [Related]
14. Complications following internal fixation of unstable distal radius fracture with a palmar locking-plate.
Arora R; Lutz M; Hennerbichler A; Krappinger D; Espen D; Gabl M
J Orthop Trauma; 2007 May; 21(5):316-22. PubMed ID: 17485996
[TBL] [Abstract][Full Text] [Related]
15. [Treatment of type C3 distal radius fractures with AO 2.4 mm locking plate system after manipulative reduction].
Zhang C; Zhang ZJ; Wang L; Niu SL; Wen YF; Guo YX
Zhongguo Gu Shang; 2014 Nov; 27(11):965-9. PubMed ID: 25577925
[TBL] [Abstract][Full Text] [Related]
16. Cast immobilization versus volar locking plate fixation of AO type C distal radial fractures in patients aged 60 years and older.
Zengin EC; Ozcan C; Aslan C; Bulut T; Sener M
Acta Orthop Traumatol Turc; 2019 Jan; 53(1):15-18. PubMed ID: 30377011
[TBL] [Abstract][Full Text] [Related]
17. Functional outcome and complications after volar plating for dorsally displaced, unstable fractures of the distal radius.
Rozental TD; Blazar PE
J Hand Surg Am; 2006 Mar; 31(3):359-65. PubMed ID: 16516728
[TBL] [Abstract][Full Text] [Related]
18. A prospective randomized trial comparing nonoperative treatment with volar locking plate fixation for displaced and unstable distal radial fractures in patients sixty-five years of age and older.
Arora R; Lutz M; Deml C; Krappinger D; Haug L; Gabl M
J Bone Joint Surg Am; 2011 Dec; 93(23):2146-53. PubMed ID: 22159849
[TBL] [Abstract][Full Text] [Related]
19. Volar locking plate (VLP) versus non-locking plate (NLP) in the treatment of die-punch fractures of the distal radius, an observational study.
Zhang X; Hu C; Yu K; Bai J; Tian D; Xu Y; Zhang B
Int J Surg; 2016 Oct; 34():142-147. PubMed ID: 27593172
[TBL] [Abstract][Full Text] [Related]
20. Size and stabilization of the dorsoulnar fragment in AO C3-type distal radius fractures.
Miyashima Y; Kaneshiro Y; Yano K; Teraura H; Sakanaka H; Uemura T
Injury; 2019 Nov; 50(11):2004-2008. PubMed ID: 31427036
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]