BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

225 related articles for article (PubMed ID: 36039433)

  • 21. Selective isolation of magnetic nanoparticle-mediated heterogeneity subpopulation of circulating tumor cells using magnetic gradient based microfluidic system.
    Kwak B; Lee J; Lee D; Lee K; Kwon O; Kang S; Kim Y
    Biosens Bioelectron; 2017 Feb; 88():153-158. PubMed ID: 27503409
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Predictive value of circulating tumor cells (CTCs) captured by microfluidic device in patients with epithelial ovarian cancer.
    Lee M; Kim EJ; Cho Y; Kim S; Chung HH; Park NH; Song YS
    Gynecol Oncol; 2017 May; 145(2):361-365. PubMed ID: 28274569
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Prognostic impact of circulating tumor cells detected with the microfluidic "universal CTC-chip" for primary lung cancer.
    Kanayama M; Kuwata T; Mori M; Nemoto Y; Nishizawa N; Oyama R; Matsumiya H; Taira A; Shinohara S; Takenaka M; Yoneda K; Kuroda K; Ohnaga T; Tanaka F
    Cancer Sci; 2022 Mar; 113(3):1028-1037. PubMed ID: 34964211
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Multivalent DNA nanospheres for enhanced capture of cancer cells in microfluidic devices.
    Sheng W; Chen T; Tan W; Fan ZH
    ACS Nano; 2013 Aug; 7(8):7067-76. PubMed ID: 23837646
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Combination of antibody-coated, physical-based microfluidic chip with wave-shaped arrays for isolating circulating tumor cells.
    Chen H; Cao B; Chen H; Lin YS; Zhang J
    Biomed Microdevices; 2017 Sep; 19(3):66. PubMed ID: 28776234
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Capture, release and culture of circulating tumor cells from pancreatic cancer patients using an enhanced mixing chip.
    Sheng W; Ogunwobi OO; Chen T; Zhang J; George TJ; Liu C; Fan ZH
    Lab Chip; 2014 Jan; 14(1):89-98. PubMed ID: 24220648
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Circulating tumor cell enumeration with a combination of epithelial cell adhesion molecule- and cell-surface vimentin-based methods for monitoring breast cancer therapeutic response.
    Satelli A; Brownlee Z; Mitra A; Meng QH; Li S
    Clin Chem; 2015 Jan; 61(1):259-66. PubMed ID: 25336717
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Improved detection by ensemble-decision aliquot ranking of circulating tumor cells with low numbers of a targeted surface antigen.
    Johnson ES; Anand RK; Chiu DT
    Anal Chem; 2015 Sep; 87(18):9389-95. PubMed ID: 26302174
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Dual-Multivalent-Aptamer-Conjugated Nanoprobes for Superefficient Discerning of Single Circulating Tumor Cells in a Microfluidic Chip with Inductively Coupled Plasma Mass Spectrometry Detection.
    Zhang X; Wei X; Men X; Wu CX; Bai JJ; Li WT; Yang T; Chen ML; Wang JH
    ACS Appl Mater Interfaces; 2021 Sep; 13(36):43668-43675. PubMed ID: 34473482
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Gene expression profiling of single circulating tumor cells inĀ ovarian cancer - Establishment of a multi-marker gene panel.
    Blassl C; Kuhlmann JD; Webers A; Wimberger P; Fehm T; Neubauer H
    Mol Oncol; 2016 Aug; 10(7):1030-42. PubMed ID: 27157930
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Analysis of circulating tumor cells from lung cancer patients with multiple biomarkers using high-performance size-based microfluidic chip.
    Gao W; Yuan H; Jing F; Wu S; Zhou H; Mao H; Jin Q; Zhao J; Cong H; Jia C
    Oncotarget; 2017 Feb; 8(8):12917-12928. PubMed ID: 28039472
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Isolation of circulating tumor cells using a microvortex-generating herringbone-chip.
    Stott SL; Hsu CH; Tsukrov DI; Yu M; Miyamoto DT; Waltman BA; Rothenberg SM; Shah AM; Smas ME; Korir GK; Floyd FP; Gilman AJ; Lord JB; Winokur D; Springer S; Irimia D; Nagrath S; Sequist LV; Lee RJ; Isselbacher KJ; Maheswaran S; Haber DA; Toner M
    Proc Natl Acad Sci U S A; 2010 Oct; 107(43):18392-7. PubMed ID: 20930119
    [TBL] [Abstract][Full Text] [Related]  

  • 33. EGFR mutation detection of lung circulating tumor cells using a multifunctional microfluidic chip.
    Wang Y; Gao W; Wu M; Zhang X; Liu W; Zhou Y; Jia C; Cong H; Chen X; Zhao J
    Talanta; 2021 Apr; 225():122057. PubMed ID: 33592778
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Optimization and Evaluation of a Novel Size Based Circulating Tumor Cell Isolation System.
    Xu L; Mao X; Imrali A; Syed F; Mutsvangwa K; Berney D; Cathcart P; Hines J; Shamash J; Lu YJ
    PLoS One; 2015; 10(9):e0138032. PubMed ID: 26397728
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Spiral shape microfluidic channel for selective isolating of heterogenic circulating tumor cells.
    Kwak B; Lee J; Lee J; Kim HS; Kang S; Lee Y
    Biosens Bioelectron; 2018 Mar; 101():311-316. PubMed ID: 29055574
    [TBL] [Abstract][Full Text] [Related]  

  • 36. A novel flow cytometry-based cell capture platform for the detection, capture and molecular characterization of rare tumor cells in blood.
    Watanabe M; Serizawa M; Sawada T; Takeda K; Takahashi T; Yamamoto N; Koizumi F; Koh Y
    J Transl Med; 2014 May; 12():143. PubMed ID: 24886394
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Toward Microfluidic Label-Free Isolation and Enumeration of Circulating Tumor Cells from Blood Samples.
    Raillon C; Che J; Thill S; Duchamp M; Desbiolles BXE; Millet A; Sollier E; Renaud P
    Cytometry A; 2019 Oct; 95(10):1085-1095. PubMed ID: 31364817
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Simultaneous on-chip isolation and characterization of circulating tumor cell sub-populations.
    Lee J; Kwak B
    Biosens Bioelectron; 2020 Nov; 168():112564. PubMed ID: 32892118
    [TBL] [Abstract][Full Text] [Related]  

  • 39. 3D printed microfluidic devices for circulating tumor cells (CTCs) isolation.
    Chen J; Liu CY; Wang X; Sweet E; Liu N; Gong X; Lin L
    Biosens Bioelectron; 2020 Feb; 150():111900. PubMed ID: 31767348
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Molecular Profiling of Pooled Circulating Tumor Cells from Prostate Cancer Patients Using a Dual-Antibody-Functionalized Microfluidic Device.
    Yin C; Wang Y; Ji J; Cai B; Chen H; Yang Z; Wang K; Luo C; Zhang W; Yuan C; Wang F
    Anal Chem; 2018 Mar; 90(6):3744-3751. PubMed ID: 29464943
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 12.