These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
85 related articles for article (PubMed ID: 3604360)
1. [Simulation of a regulation mechanism in inserting an artificial heart, by which the left and right pumps require the same output volume]. Hecht J; Körner E Z Exp Chir Transplant Kunstliche Organe; 1987; 20(2):88-93. PubMed ID: 3604360 [TBL] [Abstract][Full Text] [Related]
2. [Testing the regulation mechanism in inserting an artificial heart by model simulation]. Hecht J; Körner E Z Exp Chir Transplant Kunstliche Organe; 1987; 20(2):75-82. PubMed ID: 3604358 [TBL] [Abstract][Full Text] [Related]
3. [Validity of the arteriovenous oxygen difference as guidance for controlling the output of an artificial heart]. Hecht J; Körner E Z Exp Chir Transplant Kunstliche Organe; 1987; 20(2):83-7. PubMed ID: 3604359 [TBL] [Abstract][Full Text] [Related]
4. Hemodynamic regulation in total artificial heart recipients. Harasaki H; Takatani S; Suwa S; Jacobs G; Snow J; Kiraly R; Nosé Y Artif Organs; 1981 Feb; 5(1):38-45. PubMed ID: 7247755 [TBL] [Abstract][Full Text] [Related]
5. Continuous flow total artificial heart: modeling and feedback control in a mock circulatory system. Khalil HA; Kerr DT; Franchek MA; Metcalfe RW; Benkowski RJ; Cohn WE; Tuzun E; Radovancevic B; Frazier OH; Kadipasaoglu KA ASAIO J; 2008; 54(3):249-55. PubMed ID: 18496274 [TBL] [Abstract][Full Text] [Related]
6. [Controlling of artificial blood pumps after total heart replacement - an example of disregulation (author's transl)]. Hennig E; Affeld K; Kless H; Mohnhaupt A; Mohhaupt R; Clevert D; Keibach H; Krautzberger W; Kleine HO; Weidemann H; Bücherl ES Thoraxchir Vask Chir; 1976 Dec; 24(6):476-83. PubMed ID: 1087483 [TBL] [Abstract][Full Text] [Related]
7. Effects of a total artificial heart right stroke volume limiter on left-right hemodynamic balance. Fukamachi K; Massiello AL; Kiraly RJ; Chen JF; Himley S; Davies C; Fukumura F; Muramoto K; Olsen E; Golding LA ASAIO J; 1993; 39(3):M410-4. PubMed ID: 8268568 [TBL] [Abstract][Full Text] [Related]
8. Development of the functionally total artificial heart using an artery pump. Li GR; Zhu XD ASAIO J; 2007; 53(3):288-91. PubMed ID: 17515716 [TBL] [Abstract][Full Text] [Related]
9. Temporary left heart bypass and total artificial replacement. Bücherl ES Z Kardiol; 1985; 74 Suppl 6():65-71. PubMed ID: 3913182 [TBL] [Abstract][Full Text] [Related]
10. One month survival with the undulation pump total artificial heart in a goat. Abe Y; Chinzei T; Isoyama T; Ono T; Mochizuki S; Saito I; Iwasaki K; Ishimaru M; Karita T; Kuono A; Baba K; Imachi K Artif Organs; 2001 Jan; 25(1):69-71. PubMed ID: 11167565 [TBL] [Abstract][Full Text] [Related]
11. Left atrial pressure controller design for an artificial heart. Kitamura T IEEE Trans Biomed Eng; 1990 Feb; 37(2):164-9. PubMed ID: 2312141 [TBL] [Abstract][Full Text] [Related]
12. Factors affecting left-right heart output differences in artificial heart implanted animals. Tanaka T; Takatani S; Umezu M; Nakatani T; Adachi S; Noda H; Fukuda S; Takano H; Akutsu T Trans Am Soc Artif Intern Organs; 1985; 31():211-5. PubMed ID: 3837446 [No Abstract] [Full Text] [Related]
13. Effects of muscle pump on rotary blood pumps in dynamic exercise: a computer simulation study. Wu Y; Lim S Cardiovasc Eng; 2008 Sep; 8(3):149-58. PubMed ID: 18563564 [TBL] [Abstract][Full Text] [Related]
14. Hemodynamic effects of partial ventricular support in chronic heart failure: results of simulation validated with in vivo data. Morley D; Litwak K; Ferber P; Spence P; Dowling R; Meyns B; Griffith B; Burkhoff D J Thorac Cardiovasc Surg; 2007 Jan; 133(1):21-8. PubMed ID: 17198776 [TBL] [Abstract][Full Text] [Related]
16. An atrial hydraulic shunt in a total artificial heart. A balance mechanism for the bronchial shunt. Kung RT; Yu LS; Ochs B; Parnis S; Frazier OH ASAIO J; 1993; 39(3):M213-7. PubMed ID: 8268531 [TBL] [Abstract][Full Text] [Related]
17. A mathematical model to predict the optimal control mode for a pusher-plate total artificial heart (TAH). Stacy G; Jacobs G; Yozu R; Shimomitsu T; Watanabe T; Smith W; Navarro R; Nose Y Trans Am Soc Artif Intern Organs; 1985; 31():216-23. PubMed ID: 3837447 [TBL] [Abstract][Full Text] [Related]
18. Flow balance between the left and right cardiac output of an eccentric roller type total artificial heart. Wada H; Fukunaga S; Watari M; Sakai H; Sugawara Y; Ochikubo H; Imai K; Shibamura H; Orihashi K; Sueda T; Matsuura Y Artif Organs; 1999 Aug; 23(8):741-6. PubMed ID: 10463500 [TBL] [Abstract][Full Text] [Related]
19. [Noninvasive monitoring of pneumatically driven blood pumps based on measurements of air volume flow in the drive hose]. Schmitz KP; Nabel HJ; Scharf W; Urbaszek W; Klinkmann H Z Gesamte Inn Med; 1987 Nov; 42(22):645-9. PubMed ID: 3442074 [TBL] [Abstract][Full Text] [Related]