These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

90 related articles for article (PubMed ID: 3604882)

  • 1. Relationship of left ventricular mass to defibrillation threshold for the implantable defibrillator: a combined clinical and animal study.
    Chapman PD; Sagar KB; Wetherbee JN; Troup PJ
    Am Heart J; 1987 Aug; 114(2):274-8. PubMed ID: 3604882
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Nonthoracotomy internal defibrillation in dogs: threshold reduction using a subcutaneous chest wall electrode with a transvenous catheter electrode.
    Wetherbee JN; Chapman PD; Klopfenstein HS; Bach SM; Troup PJ
    J Am Coll Cardiol; 1987 Aug; 10(2):406-11. PubMed ID: 3598010
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Initial clinical experience with endocardial defibrillation using an implantable cardioverter/defibrillator with a triple-electrode system.
    Saksena S; Tullo NG; Krol RB; Mauro AM
    Arch Intern Med; 1989 Oct; 149(10):2333-9. PubMed ID: 2802898
    [TBL] [Abstract][Full Text] [Related]  

  • 4. The implanted defibrillator: relation of defibrillating lead configuration and clinical variables to defibrillation threshold.
    Troup PJ; Chapman PD; Olinger GN; Kleinman LH
    J Am Coll Cardiol; 1985 Dec; 6(6):1315-21. PubMed ID: 4067110
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Mechanism of cardiac defibrillation in open-chest dogs with unipolar DC-coupled simultaneous activation and shock potential recordings.
    Witkowski FX; Penkoske PA; Plonsey R
    Circulation; 1990 Jul; 82(1):244-60. PubMed ID: 2364513
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Clinical predictors of the defibrillation threshold with the unipolar implantable defibrillation system.
    Raitt MH; Johnson G; Dolack GL; Poole JE; Kudenchuk PJ; Bardy GH
    J Am Coll Cardiol; 1995 Jun; 25(7):1576-83. PubMed ID: 7759708
    [TBL] [Abstract][Full Text] [Related]  

  • 7. [The implantable automatic cardioverter-defibrillator].
    Klein H; Tröster J; Trappe HJ; Becht I; Siclari F
    Herz; 1990 Apr; 15(2):111-25. PubMed ID: 2188891
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Influence of acute coronary artery occlusion on direct ventricular defibrillation in dogs.
    Ruffy R; Schwartz DJ; Hieb BR
    Med Instrum; 1980; 14(1):23-6. PubMed ID: 7354732
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Influence of epicardial patches on defibrillation threshold with nonthoracotomy lead configurations.
    Fotuhi PC; Ideker RE; Idriss SF; Callihan RL; Walker RG; Alt EU
    Circulation; 1995 Nov; 92(10):3082-8. PubMed ID: 7586279
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Determination of patch electrode position for the internal cardioverter-defibrillator by cine computed tomography and its relation to the defibrillation threshold.
    Oeff M; Abbott JA; Scheinman ED; Yee ES; Scheinman MM; Griffin JC
    J Am Coll Cardiol; 1992 Jul; 20(1):210-7. PubMed ID: 1607527
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Impact of transvenous lead position on active-can ICD defibrillation: a computer simulation study.
    Aguel F; Eason JC; Trayanova NA; Siekas G; Fishler MG
    Pacing Clin Electrophysiol; 1999 Jan; 22(1 Pt 2):158-64. PubMed ID: 9990622
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Transvenous biventricular defibrillation.
    Meisel E; Butter C; Philippon F; Higgins S; Strickberger SA; Smith J; Hahn S; Michel U; Schubert B; Pfeiffer D
    Am J Cardiol; 2000 Nov; 86(9A):76K-85K. PubMed ID: 11084104
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Comparison of the defibrillation threshold and the upper limit of ventricular vulnerability.
    Chen PS; Shibata N; Dixon EG; Martin RO; Ideker RE
    Circulation; 1986 May; 73(5):1022-8. PubMed ID: 3698224
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Upper limit of vulnerability is a good estimator of shock strength associated with 90% probability of successful defibrillation in humans with transvenous implantable cardioverter-defibrillators.
    Swerdlow CD; Ahern T; Kass RM; Davie S; Mandel WJ; Chen PS
    J Am Coll Cardiol; 1996 Apr; 27(5):1112-8. PubMed ID: 8609329
    [TBL] [Abstract][Full Text] [Related]  

  • 15. The effects of cardiovascular drugs on the defibrillation threshold and the pathological effects on the heart using an automatic implantable defibrillator.
    Deeb GM; Hardesty RL; Griffith BP; Thompson ME; Heilman MS; Myerowitz RL
    Ann Thorac Surg; 1983 Apr; 35(4):361-6. PubMed ID: 6838263
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Pronounced increase in defibrillation threshold associated with pacing-induced cardiomyopathy in the dog.
    Lucy SD; Jones DL; Klein GJ
    Am Heart J; 1994 Feb; 127(2):366-76. PubMed ID: 8296705
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Impact of defibrillator-can size on defibrillation success with a single-lead unipolar system.
    Newby KH; Moredock L; Rembert J; Wharton JM; Natale A
    Am Heart J; 1996 Feb; 131(2):261-5. PubMed ID: 8579018
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Low-energy endocardial defibrillation using dual, triple, and quadruple electrode systems.
    Munsif AN; Saksena S; DeGroot P; Krol RB; Matthew P; Giorgberidze I; Kaushik RR; Mehra R
    Am J Cardiol; 1997 Jun; 79(12):1632-9. PubMed ID: 9202354
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Effects of myocardial infarction on catheter defibrillation threshold.
    Babbs CF; Paris RL; Tacker WA; Bourland JD
    Med Instrum; 1983; 17(1):18-20. PubMed ID: 6843409
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Role of heart mass in the developmental changes of ventricular fibrillation threshold and spontaneous defibrillation in young dogs.
    Kralios FA; Millar CK; Kralios AC
    J Dev Physiol; 1993 Mar; 19(3):119-24. PubMed ID: 8089437
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]