These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

166 related articles for article (PubMed ID: 3604924)

  • 1. Degree of reversibility of left ventricular systolic dysfunction after aortic valve replacement for isolated aortic valve stenosis.
    Rediker DE; Boucher CA; Block PC; Akins CW; Buckley MJ; Fifer MA
    Am J Cardiol; 1987 Jul; 60(1):112-8. PubMed ID: 3604924
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Aortic valve replacement in severe aortic stenosis with left ventricular dysfunction: determinants of cardiac mortality and ventricular function recovery.
    Tarantini G; Buja P; Scognamiglio R; Razzolini R; Gerosa G; Isabella G; Ramondo A; Iliceto S
    Eur J Cardiothorac Surg; 2003 Dec; 24(6):879-85. PubMed ID: 14643804
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Preoperative identification of patients likely to have left ventricular dysfunction after aortic valve replacement. Participants in the Veterans Administration Cooperative Study on Valvular Heart Disease.
    Hwang MH; Hammermeister KE; Oprian C; Henderson W; Bousvaros G; Wong M; Miller DC; Folland E; Sethi G
    Circulation; 1989 Sep; 80(3 Pt 1):I65-76. PubMed ID: 2670330
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Hemodynamic function of the standard St. Jude bileaflet disc valve has no clinical impact 10 years after aortic valve replacement.
    Lund O; Dørup I; Emmertsen K; Jensen FT; Flø C
    Scand Cardiovasc J; 2005 Sep; 39(4):237-43. PubMed ID: 16118072
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Incremental Prognostic Use of Left Ventricular Global Longitudinal Strain in Asymptomatic/Minimally Symptomatic Patients With Severe Bioprosthetic Aortic Stenosis Undergoing Redo Aortic Valve Replacement.
    Naji P; Shah S; Svensson LG; Gillinov AM; Johnston DR; Rodriguez LL; Grimm RA; Griffin BP; Desai MY
    Circ Cardiovasc Imaging; 2017 Jun; 10(6):. PubMed ID: 28559420
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Severe aortic stenosis with low transvalvular gradient and severe left ventricular dysfunction:result of aortic valve replacement in 52 patients.
    Connolly HM; Oh JK; Schaff HV; Roger VL; Osborn SL; Hodge DO; Tajik AJ
    Circulation; 2000 Apr; 101(16):1940-6. PubMed ID: 10779460
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Assessment of left ventricular and aortic valve function after aortic balloon valvuloplasty in adult patients with critical aortic stenosis.
    McKay RG; Safian RD; Lock JE; Diver DJ; Berman AD; Warren SE; Come PC; Baim DS; Mandell VE; Royal HD
    Circulation; 1987 Jan; 75(1):192-203. PubMed ID: 2947741
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Outcomes of surgical aortic valve replacement for severe aortic stenosis: Incorporation of left ventricular systolic function and stroke volume index.
    Parikh R; Goodman AL; Barr T; Sabik JF; Svensson LG; Rodriguez LL; Lytle BW; Grimm RA; Griffin BP; Desai MY
    J Thorac Cardiovasc Surg; 2015 Jun; 149(6):1558-66.e1. PubMed ID: 25869085
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Impact of coronary disease after aortic valve replacement.
    Grünenfelder J; Kilb I; Plass A; Cominelli S; Zeller D; Genoni M
    Asian Cardiovasc Thorac Ann; 2009 Jun; 17(3):248-52. PubMed ID: 19643847
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Changes in left ventricular function and mass during serial investigations after valve replacement for aortic stenosis.
    Lund O; Erlandsen M
    J Heart Valve Dis; 2000 Jul; 9(4):583-93. PubMed ID: 10947054
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Impaired left ventricular function in chronic aortic valve disease: survival and function after replacement by Björk-Shiley prosthesis.
    Schwarz F; Flameng W; Langebartels F; Sesto M; Walter P; Schlepper M
    Circulation; 1979 Jul; 60(1):48-58. PubMed ID: 445734
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Early Recovery of Left Ventricular Systolic Function After CoreValve Transcatheter Aortic Valve Replacement.
    Dauerman HL; Reardon MJ; Popma JJ; Little SH; Cavalcante JL; Adams DH; Kleiman NS; Oh JK
    Circ Cardiovasc Interv; 2016 Jun; 9(6):. PubMed ID: 27296201
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Early regression of left ventricular hypertrophy after aortic valve replacement by the Ross procedure detected by cine MRI.
    Djavidani B; Schmid FX; Keyser A; Butz B; Seitz J; Luchner A; Debl K; Feuerbach S; Nitz WR
    J Cardiovasc Magn Reson; 2004; 6(1):1-8. PubMed ID: 15054923
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Time course of regression of left ventricular hypertrophy after aortic valve replacement.
    Monrad ES; Hess OM; Murakami T; Nonogi H; Corin WJ; Krayenbuehl HP
    Circulation; 1988 Jun; 77(6):1345-55. PubMed ID: 2967128
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Long-term changes in left ventricular mass, chamber size and function after valve replacement in patients with severe aortic stenosis and depressed ejection fraction.
    Pelà G; La Canna G; Metra M; Ceconi C; Berra Centurini P; Alfieri O; Visioli O
    Cardiology; 1997; 88(4):315-22. PubMed ID: 9197424
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Impact of postoperative blood pressure control on regression of left ventricular mass following valve replacement for aortic stenosis.
    Imanaka K; Kohmoto O; Nishimura S; Yokote Y; Kyo S
    Eur J Cardiothorac Surg; 2005 Jun; 27(6):994-9. PubMed ID: 15896607
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Usefulness of left ventricular shape to predict the early recovery of left ventricular function after isolated aortic valve replacement for aortic valve stenosis.
    Matsumura Y; Gillinov AM; Toyono M; Wada N; Yamano T; Thomas JD; Shiota T
    Am J Cardiol; 2008 Dec; 102(11):1530-4. PubMed ID: 19026309
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Aortic valve replacement in true severe aortic stenosis with low gradient and low ejection fraction.
    Ozsöyler I; Lafci B; Emrecan B; Kestelli M; Bozok S; Ozbek C; Yesil M; Gürbüz A
    Heart Surg Forum; 2006; 9(4):E681-5. PubMed ID: 16757422
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Left ventricular functional recovery and remodeling in low-flow low-gradient severe aortic stenosis after transcatheter aortic valve implantation.
    Kamperidis V; Joyce E; Debonnaire P; Katsanos S; van Rosendael PJ; van der Kley F; Sianos G; Bax JJ; Ajmone Marsan N; Delgado V
    J Am Soc Echocardiogr; 2014 Aug; 27(8):817-25. PubMed ID: 24906801
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Myocardial oxygen consumption in aortic valve disease with and without left ventricular dysfunction.
    Schwitter J; Eberli FR; Ritter M; Turina M; Krayenbuehl HP
    Br Heart J; 1992 Feb; 67(2):161-9. PubMed ID: 1531759
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.