These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

161 related articles for article (PubMed ID: 3604924)

  • 21. Abnormal left ventricular intracavitary flow acceleration in patients undergoing aortic valve replacement for aortic stenosis. A marker for high postoperative morbidity and mortality.
    Aurigemma G; Battista S; Orsinelli D; Sweeney A; Pape L; Cuénoud H
    Circulation; 1992 Sep; 86(3):926-36. PubMed ID: 1516206
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Influence of preoperative left ventricular contractile reserve on postoperative ejection fraction in low-gradient aortic stenosis.
    Quere JP; Monin JL; Levy F; Petit H; Baleynaud S; Chauvel C; Pop C; Ohlmann P; Lelguen C; Dehant P; Gueret P; Tribouilloy C
    Circulation; 2006 Apr; 113(14):1738-44. PubMed ID: 16585393
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Improvement in left ventricular function assessed by tissue Doppler imaging after aortic valve replacement for severe aortic stenosis.
    Nieh CC; Teo AY; Soo WM; Lee GK; Singh D; Poh KK
    Singapore Med J; 2015 Dec; 56(12):672-6. PubMed ID: 26702162
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Relation of myocardial mechanics in severe aortic stenosis to left ventricular ejection fraction and response to aortic valve replacement.
    Carasso S; Cohen O; Mutlak D; Adler Z; Lessick J; Aronson D; Reisner SA; Rakowski H; Bolotin G; Agmon Y
    Am J Cardiol; 2011 Apr; 107(7):1052-7. PubMed ID: 21296330
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Aortic valve replacement for aortic stenosis with severe left ventricular dysfunction. Prognostic indicators.
    Connolly HM; Oh JK; Orszulak TA; Osborn SL; Roger VL; Hodge DO; Bailey KR; Seward JB; Tajik AJ
    Circulation; 1997 May; 95(10):2395-400. PubMed ID: 9170402
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Late systolic stress-diameter relation in patients with aortic valve disease before and after valve replacement.
    Bonandi L; Hess OM; Turina M; Krayenbuehl HP
    Basic Res Cardiol; 1984; 79(4):413-22. PubMed ID: 6487234
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Rapid systolic intraventricular velocities after valve replacement for aortic stenosis.
    Wiseth R; Skjaerpe T; Hatle L
    Am J Cardiol; 1993 Apr; 71(11):944-8. PubMed ID: 8465786
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Valve replacement for aortic stenosis normalizes subendocardial function in patients with normal ejection fraction.
    Lindqvist P; Bajraktari G; Molle R; Palmerini E; Holmgren A; Mondillo S; Henein MY
    Eur J Echocardiogr; 2010 Aug; 11(7):608-13. PubMed ID: 20219771
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Early Diastolic Strain Rate in Relation to Systolic and Diastolic Function and Prognosis in Aortic Stenosis.
    Dahl JS; Barros-Gomes S; Videbæk L; Poulsen MK; Issa IF; Carter-Storch R; Christensen NL; Kumme A; Pellikka PA; Møller JE
    JACC Cardiovasc Imaging; 2016 May; 9(5):519-28. PubMed ID: 27085434
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Four year follow up of aortic valve replacement for isolated aortic stenosis: a link between reduction in pressure overload, regression of left ventricular hypertrophy, and diastolic function.
    Ikonomidis I; Tsoukas A; Parthenakis F; Gournizakis A; Kassimatis A; Rallidis L; Nihoyannopoulos P
    Heart; 2001 Sep; 86(3):309-16. PubMed ID: 11514485
    [TBL] [Abstract][Full Text] [Related]  

  • 31. [Predictive factors of abnormal dynamic intraventricular gradient after valve replacement in severe aortic stenosis].
    López Ayerbe J; Evangelista Masip A; Armada Romero E; Mateos González M; González Alujas MT; García Del Castillo H; Roma García Campomanes F; Murtra Ferré M; Soler Soler J
    Rev Esp Cardiol; 2002 Feb; 55(2):127-34. PubMed ID: 11852024
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Echocardiographic determinants of LV functional improvement after transcatheter aortic valve replacement.
    Chen J; Nawaz N; Fox Z; Komlo C; Anwaruddin S; Desai N; Jagasia D; Herrmann HC; Han Y
    Catheter Cardiovasc Interv; 2016 May; 87(6):1164-72. PubMed ID: 27145743
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Impact of left ventricular systolic function on clinical and echocardiographic outcomes following transcatheter aortic valve implantation for severe aortic stenosis.
    Ewe SH; Ajmone Marsan N; Pepi M; Delgado V; Tamborini G; Muratori M; Ng AC; van der Kley F; de Weger A; Schalij MJ; Fusari M; Biglioli P; Bax JJ
    Am Heart J; 2010 Dec; 160(6):1113-20. PubMed ID: 21146666
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Outcome after valve replacement for severe aortic stenosis associated with reduced left ventricular ejection fraction.
    Maillet JM; Le Besnerais P; Benvenuti C; Noblesse E; Ruffenach A; Nataf P; Brodaty D
    J Heart Valve Dis; 2005 Nov; 14(6):760-5. PubMed ID: 16359056
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Survival benefit of aortic valve replacement in patients with severe aortic stenosis with low ejection fraction and low gradient with normal ejection fraction.
    Pai RG; Varadarajan P; Razzouk A
    Ann Thorac Surg; 2008 Dec; 86(6):1781-9. PubMed ID: 19021976
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Comparison between transcatheter and surgical prosthetic valve implantation in patients with severe aortic stenosis and reduced left ventricular ejection fraction.
    Clavel MA; Webb JG; Rodés-Cabau J; Masson JB; Dumont E; De Larochellière R; Doyle D; Bergeron S; Baumgartner H; Burwash IG; Dumesnil JG; Mundigler G; Moss R; Kempny A; Bagur R; Bergler-Klein J; Gurvitch R; Mathieu P; Pibarot P
    Circulation; 2010 Nov; 122(19):1928-36. PubMed ID: 20975002
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Indexed effective orifice area after mechanical aortic valve replacement does not affect left ventricular mass regression in elderly.
    Roscitano A; Benedetto U; Sciangula A; Merico E; Barberi F; Bianchini R; Tonelli E; Sinatra R
    Eur J Cardiothorac Surg; 2006 Feb; 29(2):139-43. PubMed ID: 16376565
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Left ventricular performance improves late after aortic valve replacement in patients with aortic stenosis and reduced ejection fraction.
    Robiolio PA; Rigolin VH; Hearne SE; Baker WA; Kisslo KB; Pierce CH; Bashore TM; Harrison JK
    Am J Cardiol; 1995 Sep; 76(8):612-5. PubMed ID: 7677090
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Profiles of coronary blood flow velocity in patients with aortic stenosis and the effect of valve replacement: a transthoracic echocardiographic study.
    Kenny A; Wisbey CR; Shapiro LM
    Br Heart J; 1994 Jan; 71(1):57-62. PubMed ID: 8297696
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Enhanced left ventricular mass regression after aortic valve replacement in patients with aortic stenosis is associated with improved long-term survival.
    Ali A; Patel A; Ali Z; Abu-Omar Y; Saeed A; Athanasiou T; Pepper J
    J Thorac Cardiovasc Surg; 2011 Aug; 142(2):285-91. PubMed ID: 21272899
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 9.