101 related articles for article (PubMed ID: 360547)
1. The usefulness of 125I-sodium lothalamate as a GFR-indicator in single intravenous injection tests.
Groth T; Tengström B
Ups J Med Sci; 1978; 83(1):53-63. PubMed ID: 360547
[TBL] [Abstract][Full Text] [Related]
2. Utility of radioisotopic filtration markers in chronic renal insufficiency: simultaneous comparison of 125I-iothalamate, 169Yb-DTPA, 99mTc-DTPA, and inulin. The Modification of Diet in Renal Disease Study.
Perrone RD; Steinman TI; Beck GJ; Skibinski CI; Royal HD; Lawlor M; Hunsicker LG
Am J Kidney Dis; 1990 Sep; 16(3):224-35. PubMed ID: 2205098
[TBL] [Abstract][Full Text] [Related]
3. 125I-iothalamate and creatinine clearances in patients with chronic renal diseases.
Tessitore N; Lo Schiavo C; Corgnati A; Previato G; Valvo E; Lupo A; Chiaramonte S; Messa P; D'Angelo A; Zatti M; Maschio G
Nephron; 1979; 24(1):41-5. PubMed ID: 492407
[TBL] [Abstract][Full Text] [Related]
4. Determination of glomerular filtration rate using technetium-99m-DTPA with differing degrees of renal function.
Morton KA; Pisani DE; Whiting JH; Cheung AK; Arias JM; Valdivia S
J Nucl Med Technol; 1997 Jun; 25(2):110-4. PubMed ID: 9239614
[TBL] [Abstract][Full Text] [Related]
5. Application of newer clearance techniques for the determination of glomerular filtration rate.
Gaspari F; Perico N; Remuzzi G
Curr Opin Nephrol Hypertens; 1998 Nov; 7(6):675-80. PubMed ID: 9864664
[TBL] [Abstract][Full Text] [Related]
6. The glomerular filtration rate in unrestrained rabbits determined by means of an implanted telemetrical device.
Vadstrup S; Bojsen J
Acta Physiol Scand; 1983 Feb; 117(2):177-82. PubMed ID: 6408892
[TBL] [Abstract][Full Text] [Related]
7. Measurement of glomerular filtration rate by fluorescent excitation of non-radioactive meglumine iothalamate.
Guesry P; Kaufman L; Orloff S; Nelson JA; Swann S; Holliday M
Clin Nephrol; 1975; 3(4):134-8. PubMed ID: 1149336
[TBL] [Abstract][Full Text] [Related]
8. A single-injection method for measuring glomerular filtration rate.
Hall JE; Guyton AC; Farr BM
Am J Physiol; 1977 Jan; 232(1):F72-6. PubMed ID: 835715
[TBL] [Abstract][Full Text] [Related]
9. A simple method for the estimation of glomerular filtration rate.
Groth T; Tengström B
Scand J Clin Lab Invest; 1977 Feb; 37(1):39-47. PubMed ID: 616025
[TBL] [Abstract][Full Text] [Related]
10. Measurement of glomerular filtration rate.
Gaspari F; Perico N; Remuzzi G
Kidney Int Suppl; 1997 Dec; 63():S151-4. PubMed ID: 9407445
[TBL] [Abstract][Full Text] [Related]
11. 125Iodine-iothalamate clearance in children. A simple method to measure glomerular filtration.
Bajaj G; Alexander SR; Browne R; Sakarcan A; Seikaly MG
Pediatr Nephrol; 1996 Feb; 10(1):25-8. PubMed ID: 8611350
[TBL] [Abstract][Full Text] [Related]
12. Measurement of glomerular filtration rate using nonradioactive Iohexol: comparison of two one-compartment models.
Rocco MV; Buckalew VM; Moore LC; Shihabi ZK
Am J Nephrol; 1996; 16(2):138-43. PubMed ID: 8919230
[TBL] [Abstract][Full Text] [Related]
13. [A new analytical method for simultaneous measurement of iothalamate and iohexol].
Isaka Y; Yamamoto S; Fujiwara Y; Shin SH; Ochi S; Kamada T; Ueda N
Rinsho Byori; 1992 Jul; 40(7):703-7. PubMed ID: 1507488
[TBL] [Abstract][Full Text] [Related]
14. Single subcutaneous injection of iothalamate sodium I 125 to measure glomerular filtration rate.
Adefuin PY; Gur A; Siegel NJ; Spencer RP; Hayslett JP
JAMA; 1976 Apr; 235(14):1467-9. PubMed ID: 946446
[TBL] [Abstract][Full Text] [Related]
15. Comparison of a single-injection technique and inulin clearance for determining glomerular filtration rate in the sheep.
Wholohan T; Yesberg NE; Cross RB
Exp Physiol; 1991 Mar; 76(2):289-91. PubMed ID: 1905557
[TBL] [Abstract][Full Text] [Related]
16. Plasma exogenous creatinine clearance test in dogs: comparison with other methods and proposed limited sampling strategy.
Watson AD; Lefebvre HP; Concordet D; Laroute V; Ferré JP; Braun JP; Conchou F; Toutain PL
J Vet Intern Med; 2002; 16(1):22-33. PubMed ID: 11826881
[TBL] [Abstract][Full Text] [Related]
17. Performance of methods to assess kidney function in a predominantly overweight sample of patients with liver disease.
Hudson JQ; Owens HM; Fleckenstein JF; Loveless VS; Krauss AG; Hak LJ
Ren Fail; 2013; 35(2):249-56. PubMed ID: 23176438
[TBL] [Abstract][Full Text] [Related]
18. Determination of Single-Kidney Glomerular Filtration Rate in Human Subjects by Using CT.
Kwon SH; Saad A; Herrmann SM; Textor SC; Lerman LO
Radiology; 2015 Aug; 276(2):490-8. PubMed ID: 25848903
[TBL] [Abstract][Full Text] [Related]
19. A simple technique for estimating glomerular filtration rate with subcutaneous injection of (125I)lothalamate.
Ott NT
Mayo Clin Proc; 1975 Nov; 50(11):664-8. PubMed ID: 1186298
[No Abstract] [Full Text] [Related]
20. Accurate, fast, and convenient measurement of glomerular filtration rate in potential renal transplant donors.
Rabito C; Halpern EF; Scott J; Tolkoff-Rubin N
Transplantation; 2010 Sep; 90(5):510-7. PubMed ID: 20595931
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]