These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

171 related articles for article (PubMed ID: 3605571)

  • 1. An evaluation of intravenous infusion pumps and controllers.
    Runciman WB; Ilsley AH; Rutten AJ; Baker D; Fronsko RR
    Anaesth Intensive Care; 1987 May; 15(2):217-28. PubMed ID: 3605571
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Lag times to steady state drug delivery by continuous intravenous infusion: direct comparison of peristaltic and syringe pump performance identifies contributions from infusion system dead volume and pump startup characteristics.
    Gibson LE; Knudsen AS; Arney D; Deng H; Sims NM; Peterfreund RA
    J Clin Monit Comput; 2022 Oct; 36(5):1489-1498. PubMed ID: 34878612
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Are peristaltic pumps as reliable as syringe pumps for metabolic research? Assessment of accuracy, precision, and metabolic kinetics.
    Mohammed BS; Fields DA; Mittendorfer B; Coggan AR; Klein S
    Metabolism; 2004 Jul; 53(7):875-8. PubMed ID: 15254880
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Accuracy of intravenous infusion pumps in continuous renal replacement therapies.
    Jenkins R; Harrison H; Chen B; Arnold D; Funk J
    ASAIO J; 1992; 38(4):808-10. PubMed ID: 1450476
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Warming of infusion syringes caused by electronic syringe pumps.
    Cornelius A; Frey B; Neff TA; Gerber AC; Weiss M
    Acta Anaesthesiol Scand; 2003 May; 47(5):549-53. PubMed ID: 12699511
    [TBL] [Abstract][Full Text] [Related]  

  • 6. High-technology i.v. infusion devices.
    Kwan JW
    Am J Hosp Pharm; 1991 Oct; 48(10 Suppl 1):S36-51. PubMed ID: 1772112
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Impact of syringe size on the performance of infusion pumps at low flow rates.
    Schmidt N; Saez C; Seri I; Maturana A
    Pediatr Crit Care Med; 2010 Mar; 11(2):282-6. PubMed ID: 19935442
    [TBL] [Abstract][Full Text] [Related]  

  • 8. [Causes of failure and dangers in the use of motor driven infusion pumps. Accidental closure of the infusion system].
    Heise D; Rathgeber J; Kettler D
    Anaesthesist; 1998 Jan; 47(1):54-8. PubMed ID: 9530448
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Cost and acceptability of three syringe-pump infusion systems.
    Johnson MS; Pesko LJ; Wood CF; Reinders TP
    Am J Hosp Pharm; 1990 Aug; 47(8):1794-8. PubMed ID: 2389788
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Performance of modern syringe infusion pump assemblies at low infusion rates in the perioperative setting.
    Baeckert M; Batliner M; Grass B; Buehler PK; Daners MS; Meboldt M; Weiss M
    Br J Anaesth; 2020 Feb; 124(2):173-182. PubMed ID: 31864721
    [TBL] [Abstract][Full Text] [Related]  

  • 11. The effect of syringe size on reliability and safety of low-flow infusions.
    Neal D; Lin JA
    Pediatr Crit Care Med; 2009 Sep; 10(5):592-6. PubMed ID: 19451854
    [TBL] [Abstract][Full Text] [Related]  

  • 12. The effect of syringe size on the performance of an infusion pump.
    Kim DW; Steward DJ
    Paediatr Anaesth; 1999; 9(4):335-7. PubMed ID: 10411770
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Evaluation of a novel flow-controlled syringe infusion pump for precise and continuous drug delivery at low flow rates: a laboratory study.
    Batliner M; Weiss M; Dual SA; Grass B; Meboldt M; Schmid Daners M
    Anaesthesia; 2019 Nov; 74(11):1425-1431. PubMed ID: 31373391
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Amount of accidental flush by syringe pump due to inappropriate release of occluded intravenous line.
    Kawakami H; Miyashita T; Yanaizumi R; Mihara T; Sato H; Kariya T; Mizuno Y; Goto T
    Technol Health Care; 2013; 21(6):581-6. PubMed ID: 24225409
    [TBL] [Abstract][Full Text] [Related]  

  • 15. An analysis of drug delivery dynamics via a pediatric central venous infusion system: quantification of delays in achieving intended doses.
    Bartels K; Moss DR; Peterfreund RA
    Anesth Analg; 2009 Oct; 109(4):1156-61. PubMed ID: 19762743
    [TBL] [Abstract][Full Text] [Related]  

  • 16. An in vitro evaluation of infusion methods using a syringe pump to improve noradrenaline administration.
    Genay S; Décaudin B; Scoccia S; Barthélémy C; Debaene B; Lebuffe G; Odou P
    Acta Anaesthesiol Scand; 2015 Feb; 59(2):197-204. PubMed ID: 25476454
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Syringe infusion pumps with dose error reduction systems.
    Health Devices; 2008 Feb; 37(2):33-51. PubMed ID: 18773865
    [TBL] [Abstract][Full Text] [Related]  

  • 18. High-technology i.v. infusion devices.
    Kwan JW
    Am J Hosp Pharm; 1989 Feb; 46(2):320-35. PubMed ID: 2653027
    [TBL] [Abstract][Full Text] [Related]  

  • 19. A comparison of infusion devices at 1 ml/hr.
    Wood BR; Huddleston K; Kolm P
    Neonatal Intensive Care; 1993; 6(3):20-2. PubMed ID: 10148553
    [TBL] [Abstract][Full Text] [Related]  

  • 20. [Pressure build-up in 2 rate-controlled syringe infusion pumps].
    Gerlif C
    Ugeskr Laeger; 1994 Apr; 156(15):2236-9. PubMed ID: 8016950
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.