154 related articles for article (PubMed ID: 36057944)
21. Improving the Feasibility of Mitigating Phase Errors in 4DCT caused by a Random Reference Breathing Pattern in the Quasar Phantom and the Role of Slice Thickness.
Balakrishnan A; Ramesh Babu P
Asian Pac J Cancer Prev; 2024 Jun; 25(6):2089-2098. PubMed ID: 38918671
[TBL] [Abstract][Full Text] [Related]
22. Clinical evaluation of 4D MRI in the delineation of gross and internal tumor volumes in comparison with 4DCT.
Zhang J; Srivastava S; Wang C; Beckham T; Johnson C; Dutta P; Shepherd A; Mechalakos J; Hunt M; Wu A; Rimner A; Li G
J Appl Clin Med Phys; 2019 Sep; 20(9):51-60. PubMed ID: 31538719
[TBL] [Abstract][Full Text] [Related]
23. Do maximum intensity projection images truly capture tumor motion?
Park K; Huang L; Gagne H; Papiez L
Int J Radiat Oncol Biol Phys; 2009 Feb; 73(2):618-25. PubMed ID: 19147026
[TBL] [Abstract][Full Text] [Related]
24. Motion vector field phase-to-amplitude resampling for 4D motion-compensated cone-beam CT.
Sauppe S; Kuhm J; Brehm M; Paysan P; Seghers D; Kachelrieß M
Phys Med Biol; 2018 Feb; 63(3):035032. PubMed ID: 29235989
[TBL] [Abstract][Full Text] [Related]
25. ITV versus mid-ventilation for treatment planning in lung SBRT: a comparison of target coverage and PTV adequacy by using in-treatment 4D cone beam CT.
Bellec J; Arab-Ceschia F; Castelli J; Lafond C; Chajon E
Radiat Oncol; 2020 Mar; 15(1):54. PubMed ID: 32127010
[TBL] [Abstract][Full Text] [Related]
26. The influence of respiratory motion on CT image volume definition.
Rodríguez-Romero R; Castro-Tejero P
Med Phys; 2014 Apr; 41(4):041701. PubMed ID: 24694121
[TBL] [Abstract][Full Text] [Related]
27. Dose calculations accounting for breathing motion in stereotactic lung radiotherapy based on 4D-CT and the internal target volume.
Admiraal MA; Schuring D; Hurkmans CW
Radiother Oncol; 2008 Jan; 86(1):55-60. PubMed ID: 18082905
[TBL] [Abstract][Full Text] [Related]
28. Comparison of an alternative and existing binning methods to reduce the acquisition duration of 4D PET/CT.
Didierlaurent D; Jaudet C; Ribes S; Batatia H; Dierickx LO; Zerdoud S; Brillouet S; Weyts K; Courbon F; Caselles O
Med Phys; 2014 Nov; 41(11):112503. PubMed ID: 25370662
[TBL] [Abstract][Full Text] [Related]
29. Intrafraction 4D-cone beam CT acquired during volumetric arc radiotherapy delivery: kV parameter optimization and 4D motion accuracy for lung stereotactic body radiotherapy (SBRT) patients.
Liang J; Lack D; Zhou J; Liu Q; Grills I; Yan D
J Appl Clin Med Phys; 2019 Dec; 20(12):10-24. PubMed ID: 31675150
[TBL] [Abstract][Full Text] [Related]
30. Quantifying the impact of respiratory-gated 4D CT acquisition on thoracic image quality: a digital phantom study.
Bernatowicz K; Keall P; Mishra P; Knopf A; Lomax A; Kipritidis J
Med Phys; 2015 Jan; 42(1):324-34. PubMed ID: 25563272
[TBL] [Abstract][Full Text] [Related]
31. Technical evaluation of different respiratory monitoring systems used for 4D CT acquisition under free breathing.
Heinz C; Reiner M; Belka C; Walter F; Söhn M
J Appl Clin Med Phys; 2015 Mar; 16(2):4917. PubMed ID: 26103168
[TBL] [Abstract][Full Text] [Related]
32. A method for improved 4D-computed tomography data acquisition.
Kupper M; Sprengel W; Winkler P; Zurl B
Z Med Phys; 2017 Mar; 27(1):31-38. PubMed ID: 27265776
[TBL] [Abstract][Full Text] [Related]
33. Treatment planning and 4D robust evaluation strategy for proton therapy of lung tumors with large motion amplitude.
Taasti VT; Hattu D; Vaassen F; Canters R; Velders M; Mannens J; van Loon J; Rinaldi I; Unipan M; van Elmpt W
Med Phys; 2021 Aug; 48(8):4425-4437. PubMed ID: 34214201
[TBL] [Abstract][Full Text] [Related]
34. Evaluation of image guided motion management methods in lung cancer radiotherapy.
Zhuang L; Yan D; Liang J; Ionascu D; Mangona V; Yang K; Zhou J
Med Phys; 2014 Mar; 41(3):031911. PubMed ID: 24593729
[TBL] [Abstract][Full Text] [Related]
35. A technique of using gated-CT images to determine internal target volume (ITV) for fractionated stereotactic lung radiotherapy.
Jin JY; Ajlouni M; Chen Q; Yin FF; Movsas B
Radiother Oncol; 2006 Feb; 78(2):177-84. PubMed ID: 16376444
[TBL] [Abstract][Full Text] [Related]
36. Characteristics of breathing-adapted gating using surface guidance for use in particle therapy: A phantom-based end-to-end test from CT simulation to dose delivery.
Qubala A; Shafee J; Tessonnier T; Horn J; Winter M; Naumann J; Jäkel O
J Appl Clin Med Phys; 2024 Jan; 25(1):e14249. PubMed ID: 38128056
[TBL] [Abstract][Full Text] [Related]
37. Evaluation of interfractional variation of the centroid position and volume of internal target volume during stereotactic body radiotherapy of lung cancer using cone-beam computed tomography.
Sun Y; Ge H; Cheng S; Yang C; Zhu Q; Li D; Tian Y
J Appl Clin Med Phys; 2016 Mar; 17(2):461-472. PubMed ID: 27074466
[TBL] [Abstract][Full Text] [Related]
38. A novel amplitude binning strategy to handle irregular breathing during 4DMRI acquisition: improved imaging for radiotherapy purposes.
van Kesteren Z; van der Horst A; Gurney-Champion OJ; Bones I; Tekelenburg D; Alderliesten T; van Tienhoven G; Klaassen R; van Laarhoven HWM; Bel A
Radiat Oncol; 2019 May; 14(1):80. PubMed ID: 31088490
[TBL] [Abstract][Full Text] [Related]
39. Intelligent 4D CT sequence scanning (i4DCT): First scanner prototype implementation and phantom measurements of automated breathing signal-guided 4D CT.
Werner R; Sentker T; Madesta F; Schwarz A; Vornehm M; Gauer T; Hofmann C
Med Phys; 2020 Jun; 47(6):2408-2412. PubMed ID: 32115724
[TBL] [Abstract][Full Text] [Related]
40. System requirements to improve adaptive 4-dimensional computed tomography (4D CT) imaging.
Morton N; O'Brien R; Keall P; Reynolds T
Biomed Phys Eng Express; 2022 Oct; 8(6):. PubMed ID: 36206724
[TBL] [Abstract][Full Text] [Related]
[Previous] [Next] [New Search]