These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

214 related articles for article (PubMed ID: 36066150)

  • 1. Comparison of C-MAC vs. McGrath video laryngoscopes on glottic exposure and endotracheal intubation success with stylet usage in obese patients.
    Karadağ Erkoç S; Yıldırım Güçlü Ç; Büyük S; Bermede O; Erkent FD; Yılmaz AA
    Eur Rev Med Pharmacol Sci; 2022 Aug; 26(16):5763-5773. PubMed ID: 36066150
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Comparison of three video laryngoscopy devices to direct laryngoscopy for intubating obese patients: a randomized controlled trial.
    Yumul R; Elvir-Lazo OL; White PF; Sloninsky A; Kaplan M; Kariger R; Naruse R; Parker N; Pham C; Zhang X; Wender RH
    J Clin Anesth; 2016 Jun; 31():71-7. PubMed ID: 27185681
    [TBL] [Abstract][Full Text] [Related]  

  • 3. A randomized controlled comparison of non-channeled king vision, McGrath MAC video laryngoscope and Macintosh direct laryngoscope for nasotracheal intubation in patients with predicted difficult intubations.
    Zhu H; Liu J; Suo L; Zhou C; Sun Y; Jiang H
    BMC Anesthesiol; 2019 Aug; 19(1):166. PubMed ID: 31470814
    [TBL] [Abstract][Full Text] [Related]  

  • 4. A Macintosh laryngoscope blade for videolaryngoscopy reduces stylet use in patients with normal airways.
    van Zundert A; Maassen R; Lee R; Willems R; Timmerman M; Siemonsma M; Buise M; Wiepking M
    Anesth Analg; 2009 Sep; 109(3):825-31. PubMed ID: 19690253
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Comparative efficacy of C-MAC
    Gupta A; Singh P; Gupta N; Kumar Malhotra R; Girdhar KK
    Paediatr Anaesth; 2021 Oct; 31(10):1089-1096. PubMed ID: 34153141
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A prospective randomized comparative trial of pediatric C-MAC D-blade video laryngoscope with McCoy direct laryngoscope for intubation in children posted for elective surgical procedures under general anesthesia.
    Kamal G; Agarwal D; Agarwal S; Gupta A; Gupta A; Kalra B; Gupta N
    Paediatr Anaesth; 2024 Aug; 34(8):750-757. PubMed ID: 38682461
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Comparison of the Effectiveness of the Miller Laryngoscope and the McGrath-MAC Video Laryngoscope in Direct Visualization of the Glottic Opening.
    Küçükosman G; Bollucuoğlu K; Ava M; Ayoğlu H
    Medicina (Kaunas); 2023 Dec; 60(1):. PubMed ID: 38256323
    [No Abstract]   [Full Text] [Related]  

  • 8. Comparison of Direct and Video Laryngoscopes during Different Airway Scenarios Performed by Experienced Paramedics: A Randomized Cross-Over Manikin Study.
    Ruetzler K; Szarpak L; Smereka J; Dabrowski M; Bialka S; Mosteller L; Szarpak A; Ludwin K; Wojewodzka-Zelezniakowicz M; Ladny JR
    Biomed Res Int; 2020; 2020():5382739. PubMed ID: 32149114
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Comparing the first-attempt tracheal intubation success of the hyperangulated McGrath® X-blade vs the Macintosh-type CMAC videolaryngoscope in patients with cervical immobilization: a two-centre randomized controlled trial.
    Zhang J; Tan LZ; Toh H; Foo CW; Wijeratne S; Hu H; Seet E
    J Clin Monit Comput; 2022 Aug; 36(4):1139-1145. PubMed ID: 34347225
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Macintosh Videolaryngoscope for Intubation in the Operating Room: A Comparative Quality Improvement Project.
    De Jong A; Pouzeratte Y; Laplace A; Normanno M; Rollé A; Verzilli D; Perrigault PF; Colson P; Capdevila X; Molinari N; Jaber S
    Anesth Analg; 2021 Feb; 132(2):524-535. PubMed ID: 32739955
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Improvement in glottic visualisation by using the C-MAC PM video laryngoscope as a first-line device for out-of-hospital emergency tracheal intubation: An observational study.
    Hossfeld B; Frey K; Doerges V; Lampl L; Helm M
    Eur J Anaesthesiol; 2015 Jun; 32(6):425-31. PubMed ID: 25886716
    [TBL] [Abstract][Full Text] [Related]  

  • 12. A comparison of three videolaryngoscopes: the Macintosh laryngoscope blade reduces, but does not replace, routine stylet use for intubation in morbidly obese patients.
    Maassen R; Lee R; Hermans B; Marcus M; van Zundert A
    Anesth Analg; 2009 Nov; 109(5):1560-5. PubMed ID: 19713258
    [TBL] [Abstract][Full Text] [Related]  

  • 13. [Comparison of five video laryngoscopes and conventional direct laryngoscopy : Investigations on simple and simulated difficult airways on the intubation trainer].
    Ruetzler K; Imach S; Weiss M; Haas T; Schmidt AR
    Anaesthesist; 2015 Jul; 64(7):513-9. PubMed ID: 26174747
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Evaluation of the McGrath MAC and Macintosh laryngoscope for tracheal intubation in 2000 patients undergoing general anaesthesia: the randomised multicentre EMMA trial study protocol.
    Kriege M; Alflen C; Tzanova I; Schmidtmann I; Piepho T; Noppens RR
    BMJ Open; 2017 Aug; 7(8):e016907. PubMed ID: 28827261
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Comparative Evaluation of McGrath MAC, Truview Video Laryngoscopes and Macintosh Laryngoscope for Endotracheal Intubation in Patients Undergoing Surgery under General Anaesthesia.
    Kaur G; Gupta S; Mehta N; Dhingra JS
    Anesth Essays Res; 2020; 14(1):20-24. PubMed ID: 32843786
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Postoperative sore throat and subglottic injury after McGrath® MAC videolaryngoscopic intubation with versus without a stylet in patients with a high Mallampati score: a randomized controlled trial.
    Yoon HK; Lee HC; Oh H; Jun K; Park HP
    BMC Anesthesiol; 2019 Jul; 19(1):137. PubMed ID: 31366325
    [TBL] [Abstract][Full Text] [Related]  

  • 17. First-Attempt Intubation Success of Video Laryngoscopy in Patients with Anticipated Difficult Direct Laryngoscopy: A Multicenter Randomized Controlled Trial Comparing the C-MAC D-Blade Versus the GlideScope in a Mixed Provider and Diverse Patient Population.
    Aziz MF; Abrons RO; Cattano D; Bayman EO; Swanson DE; Hagberg CA; Todd MM; Brambrink AM
    Anesth Analg; 2016 Mar; 122(3):740-750. PubMed ID: 26579847
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Comparing the McGrath Mac Video Laryngoscope and Direct Laryngoscopy for Prehospital Emergency Intubation in Air Rescue Patients: A Multicenter, Randomized, Controlled Trial.
    Kreutziger J; Hornung S; Harrer C; Urschl W; Doppler R; Voelckel WG; Trimmel H
    Crit Care Med; 2019 Oct; 47(10):1362-1370. PubMed ID: 31389835
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Randomized controlled trial comparing the McGrath MAC video laryngoscope with the King Vision video laryngoscope in adult patients.
    Alvis BD; Hester D; Watson D; Higgins M; St Jacques P
    Minerva Anestesiol; 2016 Jan; 82(1):30-5. PubMed ID: 25881731
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Videolaryngoscopy versus direct laryngoscopy for adult patients requiring tracheal intubation.
    Lewis SR; Butler AR; Parker J; Cook TM; Smith AF
    Cochrane Database Syst Rev; 2016 Nov; 11(11):CD011136. PubMed ID: 27844477
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 11.