These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

193 related articles for article (PubMed ID: 36068231)

  • 21. MEG-BIDS, the brain imaging data structure extended to magnetoencephalography.
    Niso G; Gorgolewski KJ; Bock E; Brooks TL; Flandin G; Gramfort A; Henson RN; Jas M; Litvak V; T Moreau J; Oostenveld R; Schoffelen JM; Tadel F; Wexler J; Baillet S
    Sci Data; 2018 Jun; 5():180110. PubMed ID: 29917016
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Non-invasive measurement of choroid plexus apparent blood flow with arterial spin labeling.
    Zhao L; Taso M; Dai W; Press DZ; Alsop DC
    Fluids Barriers CNS; 2020 Sep; 17(1):58. PubMed ID: 32962708
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Microscopy-BIDS: An Extension to the Brain Imaging Data Structure for Microscopy Data.
    Bourget MH; Kamentsky L; Ghosh SS; Mazzamuto G; Lazari A; Markiewicz CJ; Oostenveld R; Niso G; Halchenko YO; Lipp I; Takerkart S; Toussaint PJ; Khan AR; Nilsonne G; Castelli FM; ; Cohen-Adad J
    Front Neurosci; 2022; 16():871228. PubMed ID: 35516811
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Evaluation of segmented 3D acquisition schemes for whole-brain high-resolution arterial spin labeling at 3 T.
    Vidorreta M; Balteau E; Wang Z; De Vita E; Pastor MA; Thomas DL; Detre JA; Fernández-Seara MA
    NMR Biomed; 2014 Nov; 27(11):1387-96. PubMed ID: 25263944
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Arterial spin labeling in clinical pediatric imaging.
    Proisy M; Bruneau B; Rozel C; Tréguier C; Chouklati K; Riffaud L; Darnault P; Ferré JC
    Diagn Interv Imaging; 2016 Feb; 97(2):151-8. PubMed ID: 26456912
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Arterial spin labeling magnetic resonance imaging at short post-labeling delay reflects cerebral perfusion pressure verified by oxygen-15-positron emission tomography in cerebrovascular steno-occlusive disease.
    Itagaki H; Kokubo Y; Kawanami K; Sato S; Yamada Y; Sato S; Sonoda Y
    Acta Radiol; 2021 Feb; 62(2):225-233. PubMed ID: 32295388
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Comparison of pulsed arterial spin labeling encoding schemes and absolute perfusion quantification.
    Cavuşoğlu M; Pfeuffer J; Uğurbil K; Uludağ K
    Magn Reson Imaging; 2009 Oct; 27(8):1039-45. PubMed ID: 19540694
    [TBL] [Abstract][Full Text] [Related]  

  • 28. 3D Pseudocontinuous arterial spin labeling in routine clinical practice: A review of clinically significant artifacts.
    Amukotuwa SA; Yu C; Zaharchuk G
    J Magn Reson Imaging; 2016 Jan; 43(1):11-27. PubMed ID: 25857715
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Assesment of perfusion in glial tumors with arterial spin labeling; comparison with dynamic susceptibility contrast method.
    Cebeci H; Aydin O; Ozturk-Isik E; Gumus C; Inecikli F; Bekar A; Kocaeli H; Hakyemez B
    Eur J Radiol; 2014 Oct; 83(10):1914-9. PubMed ID: 25087109
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Comparison of 3T and 7T ASL techniques for concurrent functional perfusion and BOLD studies.
    Ivanov D; Gardumi A; Haast RAM; Pfeuffer J; Poser BA; Uludağ K
    Neuroimage; 2017 Aug; 156():363-376. PubMed ID: 28528845
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Pancreatic perfusion and arterial-transit-time quantification using pseudocontinuous arterial spin labeling at 3T.
    Taso M; Guidon A; Zhao L; Mortele KJ; Alsop DC
    Magn Reson Med; 2019 Jan; 81(1):542-550. PubMed ID: 30229559
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Arterial Spin Labeling: Techniques, Clinical Applications, and Interpretation.
    Iutaka T; de Freitas MB; Omar SS; Scortegagna FA; Nael K; Nunes RH; Pacheco FT; Maia Júnior ACM; do Amaral LLF; da Rocha AJ
    Radiographics; 2023 Jan; 43(1):e220088. PubMed ID: 36367822
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Comparison of simultaneous arterial spin labeling MRI and
    Puig O; Henriksen OM; Vestergaard MB; Hansen AE; Andersen FL; Ladefoged CN; Rostrup E; Larsson HB; Lindberg U; Law I
    J Cereb Blood Flow Metab; 2020 Aug; 40(8):1621-1633. PubMed ID: 31500521
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Advances in arterial spin labelling MRI methods for measuring perfusion and collateral flow.
    van Osch MJ; Teeuwisse WM; Chen Z; Suzuki Y; Helle M; Schmid S
    J Cereb Blood Flow Metab; 2018 Sep; 38(9):1461-1480. PubMed ID: 28598243
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Arterial spin labeling-fast imaging with steady-state free precession (ASL-FISP): a rapid and quantitative perfusion technique for high-field MRI.
    Gao Y; Goodnough CL; Erokwu BO; Farr GW; Darrah R; Lu L; Dell KM; Yu X; Flask CA
    NMR Biomed; 2014 Aug; 27(8):996-1004. PubMed ID: 24891124
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Measurement of brain perfusion in newborns: pulsed arterial spin labeling (PASL) versus pseudo-continuous arterial spin labeling (pCASL).
    Boudes E; Gilbert G; Leppert IR; Tan X; Pike GB; Saint-Martin C; Wintermark P
    Neuroimage Clin; 2014; 6():126-33. PubMed ID: 25379424
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Reproducibility of multiphase pseudo-continuous arterial spin labeling and the effect of post-processing analysis methods.
    Fazlollahi A; Bourgeat P; Liang X; Meriaudeau F; Connelly A; Salvado O; Calamante F
    Neuroimage; 2015 Aug; 117():191-201. PubMed ID: 26026814
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Assessment of perfusion deficits in ischemic stroke using 3D-GRASE arterial spin labeling magnetic resonance imaging with multiple inflow times.
    Wolf ME; Layer V; Gregori J; Griebe M; Szabo K; Gass A; Hennerici MG; Matthias Günther ; Rolf Kern
    J Neuroimaging; 2014; 24(5):453-9. PubMed ID: 25340181
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Multi-vendor reliability of arterial spin labeling perfusion MRI using a near-identical sequence: implications for multi-center studies.
    Mutsaerts HJ; van Osch MJ; Zelaya FO; Wang DJ; Nordhøy W; Wang Y; Wastling S; Fernandez-Seara MA; Petersen ET; Pizzini FB; Fallatah S; Hendrikse J; Geier O; Günther M; Golay X; Nederveen AJ; Bjørnerud A; Groote IR
    Neuroimage; 2015 Jun; 113():143-52. PubMed ID: 25818685
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Effects of systematic partial volume errors on the estimation of gray matter cerebral blood flow with arterial spin labeling MRI.
    Petr J; Mutsaerts HJMM; De Vita E; Steketee RME; Smits M; Nederveen AJ; Hofheinz F; van den Hoff J; Asllani I
    MAGMA; 2018 Dec; 31(6):725-734. PubMed ID: 29916058
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 10.