These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

107 related articles for article (PubMed ID: 36069138)

  • 1. Mechanism and management of leaks arising after left atrial appendage closure (LAAC).
    Charate R; Ahmed A; Aedma SK; Singh V; Garg J; Pothineni NVK; Della Rocca DG; Gopinathannair R; Natale A; Lakkireddy D
    J Cardiovasc Electrophysiol; 2023 Oct; 34(10):2136-2144. PubMed ID: 36069138
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Assessment of peri-device leaks after interventional left atrial appendage closure using standardized imaging by cardiac computed tomography angiography.
    Lindner S; Behnes M; Wenke A; Sartorius B; Ansari U; Akin M; Mashayekhi K; Vogler N; Haubenreisser H; Schoenberg SO; Borggrefe M; Akin I
    Int J Cardiovasc Imaging; 2019 Apr; 35(4):725-731. PubMed ID: 30421354
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Cardiac CT and echocardiographic evaluation of peri-device flow after percutaneous left atrial appendage closure using the AMPLATZER cardiac plug device.
    Jaguszewski M; Manes C; Puippe G; Salzberg S; Müller M; Falk V; Lüscher T; Luft A; Alkadhi H; Landmesser U
    Catheter Cardiovasc Interv; 2015 Feb; 85(2):306-12. PubMed ID: 25205611
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Transcatheter embolic coils to treat peridevice leaks after left atrial appendage closure.
    Musikantow DR; Shivamurthy P; Croft LB; Kawamura I; Turagam MK; Whang W; Dukkipati SR; Goldman ME; Reddy VY
    Heart Rhythm; 2021 May; 18(5):717-722. PubMed ID: 33549807
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Leaks after Left Atrial Appendage Closure: Ignored or Neglected?
    Jang SJ; Wong SC; Mosadegh B
    Cardiology; 2021; 146(3):384-391. PubMed ID: 33735867
    [TBL] [Abstract][Full Text] [Related]  

  • 6. 5-Year Outcomes After Left Atrial Appendage Closure: From the PREVAIL and PROTECT AF Trials.
    Reddy VY; Doshi SK; Kar S; Gibson DN; Price MJ; Huber K; Horton RP; Buchbinder M; Neuzil P; Gordon NT; Holmes DR;
    J Am Coll Cardiol; 2017 Dec; 70(24):2964-2975. PubMed ID: 29103847
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Left Atrial Appendage Closure Versus Direct Oral Anticoagulants in High-Risk Patients With Atrial Fibrillation.
    Osmancik P; Herman D; Neuzil P; Hala P; Taborsky M; Kala P; Poloczek M; Stasek J; Haman L; Branny M; Chovancik J; Cervinka P; Holy J; Kovarnik T; Zemanek D; Havranek S; Vancura V; Opatrny J; Peichl P; Tousek P; Lekesova V; Jarkovsky J; Novackova M; Benesova K; Widimsky P; Reddy VY;
    J Am Coll Cardiol; 2020 Jun; 75(25):3122-3135. PubMed ID: 32586585
    [TBL] [Abstract][Full Text] [Related]  

  • 8. The clinical impact of incomplete left atrial appendage closure with the Watchman Device in patients with atrial fibrillation: a PROTECT AF (Percutaneous Closure of the Left Atrial Appendage Versus Warfarin Therapy for Prevention of Stroke in Patients With Atrial Fibrillation) substudy.
    Viles-Gonzalez JF; Kar S; Douglas P; Dukkipati S; Feldman T; Horton R; Holmes D; Reddy VY
    J Am Coll Cardiol; 2012 Mar; 59(10):923-9. PubMed ID: 22381428
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Computed tomography measurement for left atrial appendage closure.
    Asami M;
    Cardiovasc Interv Ther; 2022 Jul; 37(3):440-449. PubMed ID: 35307794
    [TBL] [Abstract][Full Text] [Related]  

  • 10. First Experience of Transcatheter Leak Occlusion With Detachable Coils Following Left Atrial Appendage Closure.
    Della Rocca DG; Horton RP; Di Biase L; Bassiouny M; Al-Ahmad A; Mohanty S; Gasperetti A; Natale VN; Trivedi C; Gianni C; Burkhardt JD; Gallinghouse GJ; Hranitzky P; Sanchez JE; Natale A
    JACC Cardiovasc Interv; 2020 Feb; 13(3):306-319. PubMed ID: 31954677
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Left atrial appendage orifice diameter measured with trans-esophageal echocardiography is independently related with peri-device leakage after Watchman device implantation.
    Chen YY; Zhang YH; Chen X; Huang WP; Xu B; Su X; Chen YH
    Int J Cardiovasc Imaging; 2019 Oct; 35(10):1831-1839. PubMed ID: 31321654
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Leak closure following left atrial appendage exclusion procedures: A multicenter registry.
    Killu AM; Gbolabo Adeola O; Della Rocca DG; Ellis C; Sugrue AM; Simard T; Friedman PA; Kawsara A; Horton RP; Natale A; Alkhouli M; Holmes DR
    Catheter Cardiovasc Interv; 2022 May; 99(6):1867-1876. PubMed ID: 35233927
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Short term outcome after left atrial appendage occlusion with the AMPLATZER Amulet and WATCHMAN device: results from the ORIGINAL registry (saxOnian RegIstry analyzinG and followINg left atrial Appendage cLosure).
    Kretzler L; Mues C; Wunderlich C; Langbein A; Spitzer SG; Gerk U; Schellong S; Ketteler T; Neuser H; Schwefer M; Strasser R; Ibrahim K; Schoen S; Christoph M
    BMC Cardiovasc Disord; 2022 Jun; 22(1):271. PubMed ID: 35710343
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Impact of Peridevice Leak on 5-Year Outcomes After Left Atrial Appendage Closure.
    Dukkipati SR; Holmes DR; Doshi SK; Kar S; Singh SM; Gibson D; Price MJ; Natale A; Mansour M; Sievert H; Houle VM; Allocco DJ; Reddy VY
    J Am Coll Cardiol; 2022 Aug; 80(5):469-483. PubMed ID: 35902169
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Percutaneous left atrial appendage closure in patients with primary hemostasis disorders and atrial fibrillation.
    Dognin N; Salaun E; Champagne C; Domain G; O'Hara G; Philippon F; Paradis JM; Faroux L; Beaudoin J; O'Connor K; Bernier M; Rodés-Cabau J; Champagne J
    J Interv Card Electrophysiol; 2022 Aug; 64(2):497-509. PubMed ID: 34822043
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Clinical efficacy and safety comparison of Watchman device versus ACP/Amulet device for percutaneous left atrial appendage closure in patients with nonvalvular atrial fibrillation: A study-level meta-analysis of clinical trials.
    Bing S; Chen RR
    Clin Cardiol; 2023 Feb; 46(2):117-125. PubMed ID: 36448417
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Clinical Implications of Leaks Following Left Atrial Appendage Ligation With the LARIAT Device.
    Gianni C; Di Biase L; Trivedi C; Mohanty S; Gökoğlan Y; Güneş MF; Bai R; Al-Ahmad A; Burkhardt JD; Horton RP; Krumerman AK; Palma EC; Valderrábano M; Gibson D; Price MJ; Natale A
    JACC Cardiovasc Interv; 2016 May; 9(10):1051-7. PubMed ID: 27198686
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Systematic review on left atrial appendage closure with the LAmbre device in patients with non-valvular atrial fibrillation.
    Ali M; Rigopoulos AG; Mammadov M; Torky A; Auer A; Matiakis M; Abate E; Bakogiannis C; Tzikas S; Bigalke B; Sedding D; Noutsias M
    BMC Cardiovasc Disord; 2020 Feb; 20(1):78. PubMed ID: 32050904
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Efficacy and safety of left atrial appendage closure in non-valvular atrial fibrillation in patients over 75 years.
    Yu J; Chen H; Post F; Muenzel M; Keil T; Hou CR; Zhao M; Meng Z; Jiang L
    Heart Vessels; 2019 Nov; 34(11):1858-1865. PubMed ID: 31144099
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Peridevice Leaks: The Plot Hole of Left Atrial Appendage Closure for Stroke Prophylaxis.
    Schmidt B; Chun KRJ
    J Am Coll Cardiol; 2022 Aug; 80(5):484-485. PubMed ID: 35902170
    [No Abstract]   [Full Text] [Related]  

    [Next]    [New Search]
    of 6.