These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
4. Impact of Microbubble Degradation and Flow Velocity on Subharmonic-aided Pressure Estimation (SHAPE): An Experimental Investigation. Zhang L; Dong YF; Chen Y; Li XG; Wang YH; Wang Y; Ge ZT; Wang X; Cai S; Yang X; Zhu QL; Li JC Ultrasound Med Biol; 2024 Jul; 50(7):1020-1027. PubMed ID: 38594125 [TBL] [Abstract][Full Text] [Related]
5. Noninvasive Evaluation of Cardiac Chamber Pressures Using Subharmonic-Aided Pressure Estimation With Definity Microbubbles. Esposito C; Machado P; McDonald ME; Savage MP; Fischman D; Mehrotra P; Cohen IS; Ruggiero N; Walinsky P; Vishnevsky A; Dickie K; Davis M; Forsberg F; Dave JK JACC Cardiovasc Imaging; 2023 Feb; 16(2):224-235. PubMed ID: 36648035 [TBL] [Abstract][Full Text] [Related]
6. The Effect of Mixing Iodinated Contrast Media and Ultrasound Contrast Agents on Subharmonic Signals. Esposito C; Tzan K; Machado P; Forsberg F; Dave JK Ultrason Imaging; 2024 Mar; 46(2):130-134. PubMed ID: 38318708 [TBL] [Abstract][Full Text] [Related]
7. Processing of subharmonic signals from ultrasound contrast agents to determine ambient pressures. Dave JK; Halldorsdottir VG; Eisenbrey JR; Forsberg F Ultrason Imaging; 2012 Apr; 34(2):81-92. PubMed ID: 22724314 [TBL] [Abstract][Full Text] [Related]
8. Subharmonic contrast microbubble signals for noninvasive pressure estimation under static and dynamic flow conditions. Halldorsdottir VG; Dave JK; Leodore LM; Eisenbrey JR; Park S; Hall AL; Thomenius K; Forsberg F Ultrason Imaging; 2011 Jul; 33(3):153-64. PubMed ID: 21842580 [TBL] [Abstract][Full Text] [Related]
9. Effect of Pulse Shaping on Subharmonic Aided Pressure Estimation In Vitro and In Vivo. Gupta I; Eisenbrey J; Stanczak M; Sridharan A; Dave JK; Liu JB; Hazard C; Wang X; Wang P; Li H; Wallace K; Forsberg F J Ultrasound Med; 2017 Jan; 36(1):3-11. PubMed ID: 27943411 [TBL] [Abstract][Full Text] [Related]
10. Contrast-Enhanced Subharmonic Aided Pressure Estimation (SHAPE) using Ultrasound Imaging with a Focus on Identifying Portal Hypertension. Forsberg F; Gupta I; Machado P; Shaw CM; Fenkel JM; Wallace K; Eisenbrey JR J Vis Exp; 2020 Dec; (166):. PubMed ID: 33346203 [TBL] [Abstract][Full Text] [Related]
11. [Experimental study on high-frequency subharmonic scattering characteristics of ultrasound contrast agent microbubbles under low ambient pressure]. Lu H; Wang Y; Huang L; Xu G; Zhou J; Yu W; Li F Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2023 Dec; 40(6):1209-1216. PubMed ID: 38151945 [TBL] [Abstract][Full Text] [Related]
12. Ambient Pressure Sensitivity of the Subharmonic Response of Coated Microbubbles: Effects of Acoustic Excitation Parameters. Azami RH; Forsberg F; Eisenbrey JR; Sarkar K Ultrasound Med Biol; 2023 Jul; 49(7):1550-1560. PubMed ID: 37100673 [TBL] [Abstract][Full Text] [Related]
13. Noninvasive estimation of dynamic pressures in vitro and in vivo using the subharmonic response from microbubbles. Dave JK; Halldorsdottir VG; Eisenbrey JR; Liu JB; McDonald ME; Dickie K; Leung C; Forsberg F IEEE Trans Ultrason Ferroelectr Freq Control; 2011 Oct; 58(10):2056-66. PubMed ID: 21989870 [TBL] [Abstract][Full Text] [Related]
14. Impact of Filling Gas on Subharmonic Emissions of Phospholipid Ultrasound Contrast Agents. Kanbar E; Fouan D; Sennoga CA; Doinikov AA; Bouakaz A Ultrasound Med Biol; 2017 May; 43(5):1004-1015. PubMed ID: 28214036 [TBL] [Abstract][Full Text] [Related]
15. The effect of amplitude modulation on subharmonic imaging with chirp excitation. Harput S; Arif M; McLaughlan J; Cowell DM; Freear S IEEE Trans Ultrason Ferroelectr Freq Control; 2013 Dec; 60(12):2532-44. PubMed ID: 24297019 [TBL] [Abstract][Full Text] [Related]
16. Improved Sensitivity of Ultrasound-Based Subharmonic Aided Pressure Estimation Using Monodisperse Microbubbles. van Hoeve W; de Vargas Serrano M; Te Winkel L; Forsberg F; Dave JK; Sarkar K; Wessner CE; Eisenbrey JR J Ultrasound Med; 2022 Jul; 41(7):1781-1789. PubMed ID: 34724241 [TBL] [Abstract][Full Text] [Related]
17. A Low-Cost, Durable and Re-Usable Bladder Phantom: Teaching Intravesical Ultrasound Contrast Administration. Shellikeri S; Back SJ; Poznick L; Darge K Ultrasound Med Biol; 2018 Aug; 44(8):1918-1926. PubMed ID: 29801978 [TBL] [Abstract][Full Text] [Related]
18. Correlation Between Portal Vein Pressure and Subharmonic Scattering Signals From SonoVue Microbubbles in Canines. Lu H; Xu G; Wang Y; Yang H; Li D; Huang L; Su M; Li C; Qiu W; Mao Y; Yu W; Li F Ultrasound Med Biol; 2023 Jan; 49(1):203-211. PubMed ID: 36266141 [TBL] [Abstract][Full Text] [Related]
19. On the implementation of an automated acoustic output optimization algorithm for subharmonic aided pressure estimation. Dave JK; Halldorsdottir VG; Eisenbrey JR; Merton DA; Liu JB; Machado P; Zhao H; Park S; Dianis S; Chalek CL; Thomenius KE; Brown DB; Forsberg F Ultrasonics; 2013 Apr; 53(4):880-8. PubMed ID: 23347593 [TBL] [Abstract][Full Text] [Related]
20. Developing an Interface and Investigating Optimal Parameters for Real-Time Intracardiac Subharmonic-Aided Pressure Estimation. Esposito C; Dickie K; Forsberg F; Dave JK IEEE Trans Ultrason Ferroelectr Freq Control; 2021 Mar; 68(3):579-585. PubMed ID: 32784134 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]