154 related articles for article (PubMed ID: 36079334)
1. Effect of Marginal Bone Integrity and Aftermarket Abutment Screws on Dental Implant Systems-A Preliminary Study with Finite Element Method.
Wu YL; Tsai MH; Chen HS; Lin CP; Wu AY
Materials (Basel); 2022 Aug; 15(17):. PubMed ID: 36079334
[TBL] [Abstract][Full Text] [Related]
2. Biomechanical effects of original equipment manufacturer and aftermarket abutment screws in zirconia abutment on dental implant assembly.
Wu YL; Tsai MH; Chen HS; Chang YT; Lin TT; Wu AY
Sci Rep; 2020 Oct; 10(1):18406. PubMed ID: 33110137
[TBL] [Abstract][Full Text] [Related]
3. Influence of Abutment Design on Stress Distribution in Narrow Implants with Marginal Bone Loss: A Finite Element Analysis.
Yenigun S; Ercal P; Ozden-Yenigun E; Katiboglu AB
Int J Oral Maxillofac Implants; 2021; 36(4):640-649. PubMed ID: 34411203
[TBL] [Abstract][Full Text] [Related]
4. Effects of the implant design on peri-implant bone stress and abutment micromovement: three-dimensional finite element analysis of original computer-aided design models.
Yamanishi Y; Yamaguchi S; Imazato S; Nakano T; Yatani H
J Periodontol; 2014 Sep; 85(9):e333-8. PubMed ID: 24835549
[TBL] [Abstract][Full Text] [Related]
5. Effects of Marginal Bone Loss Progression on Stress Distribution in Different Implant-Abutment Connections and Abutment Materials: A 3D Finite Element Analysis Study.
Lin CP; Shyu YT; Wu YL; Tsai MH; Chen HS; Wu AY
Materials (Basel); 2022 Aug; 15(17):. PubMed ID: 36079245
[TBL] [Abstract][Full Text] [Related]
6. Effects of abutment screw preload in two implant connection systems: A 3D finite element study.
Jung WK; Lee WS; Kwon HB
J Prosthet Dent; 2019 Nov; 122(5):474.e1-474.e8. PubMed ID: 31590980
[TBL] [Abstract][Full Text] [Related]
7. Marginal bone loss influence on the biomechanics of single implant crowns.
Romeed SA; Malik R; Dunne SM
J Craniofac Surg; 2013 Jul; 24(4):1459-65. PubMed ID: 23851832
[TBL] [Abstract][Full Text] [Related]
8. Vertical fracture and marginal bone loss of internal-connection implants: a finite element analysis.
Jimbo R; Halldin A; Janda M; Wennerberg A; Vandeweghe S
Int J Oral Maxillofac Implants; 2013; 28(4):e171-6. PubMed ID: 23869374
[TBL] [Abstract][Full Text] [Related]
9. Parafunctional loading and occlusal device on stress distribution around implants: A 3D finite element analysis.
Borges Radaelli MT; Idogava HT; Spazzin AO; Noritomi PY; Boscato N
J Prosthet Dent; 2018 Oct; 120(4):565-572. PubMed ID: 29724560
[TBL] [Abstract][Full Text] [Related]
10. Influences of implant neck design and implant-abutment joint type on peri-implant bone stress and abutment micromovement: three-dimensional finite element analysis.
Yamanishi Y; Yamaguchi S; Imazato S; Nakano T; Yatani H
Dent Mater; 2012 Nov; 28(11):1126-33. PubMed ID: 22920538
[TBL] [Abstract][Full Text] [Related]
11. In vitro fatigue tests and in silico finite element analysis of dental implants with different fixture/abutment joint types using computer-aided design models.
Yamaguchi S; Yamanishi Y; Machado LS; Matsumoto S; Tovar N; Coelho PG; Thompson VP; Imazato S
J Prosthodont Res; 2018 Jan; 62(1):24-30. PubMed ID: 28427837
[TBL] [Abstract][Full Text] [Related]
12. Biomechanical Comparison of Different Implant Inclinations and Cantilever Lengths in All-on-4 Treatment Concept by Three-Dimensional Finite Element Analysis.
Ozan O; Kurtulmus-Yilmaz S
Int J Oral Maxillofac Implants; 2018; 33(1):64-71. PubMed ID: 29340344
[TBL] [Abstract][Full Text] [Related]
13. Effect of increased crown height on stress distribution in short dental implant components and their surrounding bone: A finite element analysis.
Bulaqi HA; Mousavi Mashhadi M; Safari H; Samandari MM; Geramipanah F
J Prosthet Dent; 2015 Jun; 113(6):548-57. PubMed ID: 25794917
[TBL] [Abstract][Full Text] [Related]
14. Biomechanical Evaluation of Different Implant-Abutment Connections, Retention Systems, and Restorative Materials in the Implant-Supported Single Crowns Using 3D Finite Element Analysis.
Lemos CAA; Verri FR; Noritomi PY; de Souza Batista VE; Cruz RS; de Luna Gomes JM; de Oliveira Limírio JPJ; Pellizzer EP
J Oral Implantol; 2022 Jun; 48(3):194-201. PubMed ID: 34091686
[TBL] [Abstract][Full Text] [Related]
15. Effect of bone quality and bone loss level around internal and external connection implants: A finite element analysis study.
Lemos CAA; Verri FR; Noritomi PY; Kemmoku DT; Souza Batista VE; Cruz RS; de Luna Gomes JM; Pellizzer EP
J Prosthet Dent; 2021 Jan; 125(1):137.e1-137.e10. PubMed ID: 33139058
[TBL] [Abstract][Full Text] [Related]
16. 3D metal printing in dentistry: An in vitro biomechanical comparative study of two additive manufacturing technologies for full-arch implant-supported prostheses.
Barbin T; Velôso DV; Del Rio Silva L; Borges GA; Presotto AGC; Barão VAR; Mesquita MF
J Mech Behav Biomed Mater; 2020 Aug; 108():103821. PubMed ID: 32469723
[TBL] [Abstract][Full Text] [Related]
17. Influence of abutment screw preload on stress distribution in marginal bone.
Khraisat A
Int J Oral Maxillofac Implants; 2012; 27(2):303-7. PubMed ID: 22442768
[TBL] [Abstract][Full Text] [Related]
18. Influence of occlusal forces on stress distribution in preloaded dental implant screws.
Alkan I; Sertgöz A; Ekici B
J Prosthet Dent; 2004 Apr; 91(4):319-25. PubMed ID: 15116032
[TBL] [Abstract][Full Text] [Related]
19. Effect of peri-implant bone resorption on mechanical stress in the implant body: In vivo measured load-based finite element analysis.
Bing L; Mito T; Yoda N; Sato E; Shigemitsu R; Han JM; Sasaki K
J Oral Rehabil; 2020 Dec; 47(12):1566-1573. PubMed ID: 32969078
[TBL] [Abstract][Full Text] [Related]
20. Influence of shoulder coverage difference of abutment on stress distribution and screw stability in tissue-level internal connection implants: A finite element analysis and in vitro study.
Lee HY; Yang SW; Kang YJ; Oh KC; Kim JH
J Prosthet Dent; 2021 Apr; 125(4):682.e1-682.e10. PubMed ID: 33551133
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]