These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
118 related articles for article (PubMed ID: 36082958)
1. The influencing mechanism of iliac vein stent implantation for hemodynamics at the bifurcation. Li C; Feng H; Wang X; Wang Y Comput Methods Biomech Biomed Engin; 2023 Sep; 26(12):1452-1461. PubMed ID: 36082958 [TBL] [Abstract][Full Text] [Related]
2. Mechanism of effect of stenting on hemodynamics at iliac vein bifurcation. Hu J; Feng H; Zheng Y; Wang K; Wang X; Su J Comput Biol Med; 2024 Mar; 170():107968. PubMed ID: 38244472 [TBL] [Abstract][Full Text] [Related]
3. Impact of lower limb movements on iliac vein stenting in iliac vein compression syndrome patients: insights from computational modeling. Lu J; Fan Z; Ye X; Deng X; Feng H; Liu M Acta Bioeng Biomech; 2024 Jun; 26(1):23-35. PubMed ID: 39219086 [No Abstract] [Full Text] [Related]
4. Influence of the Anatomical Structure on the Hemodynamics of Iliac Vein Stenosis. Changsheng L; Haiquan F; Kun W; Xiaotian W; Yonggang W J Biomech Eng; 2023 Jan; 145(1):. PubMed ID: 36000921 [TBL] [Abstract][Full Text] [Related]
5. Local hemodynamic changes caused by main branch stent implantation and subsequent virtual side branch balloon angioplasty in a representative coronary bifurcation. Williams AR; Koo BK; Gundert TJ; Fitzgerald PJ; LaDisa JF J Appl Physiol (1985); 2010 Aug; 109(2):532-40. PubMed ID: 20507966 [TBL] [Abstract][Full Text] [Related]
6. An ultrasound imaging and computational fluid dynamics protocol to assess hemodynamics in iliac vein compression syndrome. Assi IZ; Lynch SR; Samulak K; Williams DM; Wakefield TW; Obi AT; Figueroa CA J Vasc Surg Venous Lymphat Disord; 2023 Sep; 11(5):1023-1033.e5. PubMed ID: 37353157 [TBL] [Abstract][Full Text] [Related]
7. Effect of stent treatment on hemodynamics in iliac vein compression syndrome with collateral vein. Li C; Zhan Y; Wang Z; Gao Y; Ye K; Lu X; Qiu P; Yao C Med Eng Phys; 2023 May; 115():103983. PubMed ID: 37120173 [TBL] [Abstract][Full Text] [Related]
8. Hemodynamic Comparison of Stent-Grafts for the Treatment of Aortoiliac Occlusive Disease. Chong A; Mirgolbabaee H; Sun Z; van de Velde L; Jansen S; Doyle B; Versluis M; Reijnen MMPJ; Groot Jebbink E J Endovasc Ther; 2021 Aug; 28(4):623-635. PubMed ID: 34076554 [TBL] [Abstract][Full Text] [Related]
9. Alterations in regional vascular geometry produced by theoretical stent implantation influence distributions of wall shear stress: analysis of a curved coronary artery using 3D computational fluid dynamics modeling. LaDisa JF; Olson LE; Douglas HA; Warltier DC; Kersten JR; Pagel PS Biomed Eng Online; 2006 Jun; 5():40. PubMed ID: 16780592 [TBL] [Abstract][Full Text] [Related]
10. Computational fluid dynamics analysis of balloon-expandable coronary stents: influence of stent and vessel deformation. Martin DM; Murphy EA; Boyle FJ Med Eng Phys; 2014 Aug; 36(8):1047-56. PubMed ID: 24953569 [TBL] [Abstract][Full Text] [Related]
11. Computational Comparison Between a Classic Bifurcated Endograft and a Customized Model With "Dog Bone"-Shaped Limbs. Georgakarakos E; Xenakis A; Georgiadis GS J Endovasc Ther; 2019 Apr; 26(2):250-257. PubMed ID: 30898071 [TBL] [Abstract][Full Text] [Related]
12. Studying the effect of stent thickness and porosity on post-stent implantation hemodynamics. Nada A; Hassan MA; Fakhr MA; El-Wakad MTI J Med Eng Technol; 2021 Jul; 45(5):408-416. PubMed ID: 33945392 [TBL] [Abstract][Full Text] [Related]
13. Hemodynamics of Stent Implantation Procedures in Coronary Bifurcations: An In Vitro Study. Brindise MC; Chiastra C; Burzotta F; Migliavacca F; Vlachos PP Ann Biomed Eng; 2017 Mar; 45(3):542-553. PubMed ID: 27460012 [TBL] [Abstract][Full Text] [Related]
14. The conical stent in coronary artery improves hemodynamics compared with the traditional cylindrical stent. Yu Y; Zhou Y; Ma Q; Jia S; Wu S; Sun Y; Liu X; Zhao Y; Liu Y; Shi D Int J Cardiol; 2017 Jan; 227():166-171. PubMed ID: 27863293 [TBL] [Abstract][Full Text] [Related]
15. Influence of Iliac Vein Stent Implantation on the Contralateral Iliac Vein. Zhang X; Chen Z; Sun Y; Xu M; Pan G Vasc Endovascular Surg; 2015; 49(5-6):119-23. PubMed ID: 26335993 [TBL] [Abstract][Full Text] [Related]
16. Morphometric and Hemodynamic Analysis of the Compressed Iliac Vein. Wang H; Jia W; Xi Y; Li Y; Fan Y; Deng X; Chen Z J Endovasc Ther; 2024 Aug; 31(4):744-755. PubMed ID: 36408873 [TBL] [Abstract][Full Text] [Related]
17. Impact of bifurcation angle and other anatomical characteristics on blood flow - A computational study of non-stented and stented coronary arteries. Beier S; Ormiston J; Webster M; Cater J; Norris S; Medrano-Gracia P; Young A; Cowan B J Biomech; 2016 Jun; 49(9):1570-1582. PubMed ID: 27062590 [TBL] [Abstract][Full Text] [Related]
18. Computational fluid dynamics: hemodynamic changes in abdominal aortic aneurysm after stent-graft implantation. Frauenfelder T; Lotfey M; Boehm T; Wildermuth S Cardiovasc Intervent Radiol; 2006; 29(4):613-23. PubMed ID: 16508795 [TBL] [Abstract][Full Text] [Related]
19. Flow and wall shear stress characterization after endovascular aneurysm repair and endovascular aneurysm sealing in an infrarenal aneurysm model. Boersen JT; Groot Jebbink E; Versluis M; Slump CH; Ku DN; de Vries JPM; Reijnen MMPJ J Vasc Surg; 2017 Dec; 66(6):1844-1853. PubMed ID: 28285931 [TBL] [Abstract][Full Text] [Related]
20. A hemodynamic study of blood flow models on various stent graft configurations during aorto-iliac reconstruction. Tzirakis K; Kontopodis N; Ioannou CV Clin Hemorheol Microcirc; 2024; 87(2):199-219. PubMed ID: 38363603 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]