These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

131 related articles for article (PubMed ID: 36085816)

  • 1. Standalone electrical impedance tomography predicts spirometry indicators and enables regional lung assessment.
    Zouari F; Oon WY; Modak D; Kwok WC; Cao P; Lee WN; Tam TCC; Wong EC; Chan RW
    Annu Int Conf IEEE Eng Med Biol Soc; 2022 Jul; 2022():3277-3280. PubMed ID: 36085816
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Affordable, portable and self-administrable electrical impedance tomography enables global and regional lung function assessment.
    Zouari F; Oon WY; Modak D; Lee WH; Kwok WC; Cao P; Lee WN; Tam TCC; Wong EC; Chan RW
    Sci Rep; 2022 Nov; 12(1):20613. PubMed ID: 36450830
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Global and regional lung function in cystic fibrosis measured by electrical impedance tomography.
    Lehmann S; Leonhardt S; Ngo C; Bergmann L; Ayed I; Schrading S; Tenbrock K
    Pediatr Pulmonol; 2016 Nov; 51(11):1191-1199. PubMed ID: 27127915
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Lobe based image reconstruction in Electrical Impedance Tomography.
    Schullcke B; Gong B; Krueger-Ziolek S; Tawhai M; Adler A; Mueller-Lisse U; Moeller K
    Med Phys; 2017 Feb; 44(2):426-436. PubMed ID: 28121374
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Linearity of electrical impedance tomography during maximum effort breathing and forced expiration maneuvers.
    Ngo C; Leonhardt S; Zhang T; Lüken M; Misgeld B; Vollmer T; Tenbrock K; Lehmann S
    Physiol Meas; 2017 Jan; 38(1):77-86. PubMed ID: 28004642
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Changes in the thoracic impedance distribution under different ventilatory conditions.
    Hahn G; Sipinková I; Baisch F; Hellige G
    Physiol Meas; 1995 Aug; 16(3 Suppl A):A161-73. PubMed ID: 8528115
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Global and regional degree of obstruction determined by electrical impedance tomography in patients with obstructive ventilatory defect.
    Zhang C; Dai M; Liu W; Bai X; Wu J; Xu C; Xia J; Fu F; Shi X; Dong X; Jin F; You F
    PLoS One; 2018; 13(12):e0209473. PubMed ID: 30571739
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Time-based pulmonary features from electrical impedance tomography demonstrate ventilation heterogeneity in chronic obstructive pulmonary disease.
    Milne S; Huvanandana J; Nguyen C; Duncan JM; Chapman DG; Tonga KO; Zimmermann SC; Slattery A; King GG; Thamrin C
    J Appl Physiol (1985); 2019 Nov; 127(5):1441-1452. PubMed ID: 31556831
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Flow-volume loops measured with electrical impedance tomography in pediatric patients with asthma.
    Ngo C; Dippel F; Tenbrock K; Leonhardt S; Lehmann S
    Pediatr Pulmonol; 2018 May; 53(5):636-644. PubMed ID: 29405616
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Regional lung response to bronchodilator reversibility testing determined by electrical impedance tomography in chronic obstructive pulmonary disease.
    Vogt B; Zhao Z; Zabel P; Weiler N; Frerichs I
    Am J Physiol Lung Cell Mol Physiol; 2016 Jul; 311(1):L8-L19. PubMed ID: 27190067
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Evaluation of surrogate measures of pulmonary function derived from electrical impedance tomography data in children with cystic fibrosis.
    Muller PA; Mueller JL; Mellenthin M; Murthy R; Capps M; Wagner BD; Alsaker M; Deterding R; Sagel SD; Hoppe J
    Physiol Meas; 2018 Apr; 39(4):045008. PubMed ID: 29565263
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Assessment of regional ventilation distribution: comparison of vibration response imaging (VRI) with electrical impedance tomography (EIT).
    Shi C; Boehme S; Bentley AH; Hartmann EK; Klein KU; Bodenstein M; Baumgardner JE; David M; Ullrich R; Markstaller K
    PLoS One; 2014; 9(1):e86638. PubMed ID: 24475160
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Determination of respiratory gas flow by electrical impedance tomography in an animal model of mechanical ventilation.
    Bodenstein M; Boehme S; Bierschock S; Vogt A; David M; Markstaller K
    BMC Pulm Med; 2014 Apr; 14():73. PubMed ID: 24779960
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Ultrasound detection of diaphragm position in the region for lung monitoring by electrical impedance tomography during laparoscopy.
    Buzkova K; Muller M; Rara A; Roubik K; Tyll T
    Biomed Pap Med Fac Univ Palacky Olomouc Czech Repub; 2018 Mar; 162(1):43-46. PubMed ID: 29467544
    [TBL] [Abstract][Full Text] [Related]  

  • 15. [Measuring breathing pattern in patients with chronic obstructive pulmonary disease by electrical impedance tomography].
    Balleza M; Calaf N; Feixas T; González M; Antón D; Riu PJ; Casan P
    Arch Bronconeumol; 2009 Jul; 45(7):320-4. PubMed ID: 19497652
    [TBL] [Abstract][Full Text] [Related]  

  • 16. The influence of an electrical impedance tomography belt on lung function determined by spirometry in sitting position.
    Zhang N; Jiang H; Zhang C; Li Q; Li Y; Zhang B; Deng J; Niu G; Yang B; Frerichs I; Moeller K; Fu F; Zhao Z
    Physiol Meas; 2020 May; 41(4):044002. PubMed ID: 32160596
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Regional ventilation in cystic fibrosis measured by electrical impedance tomography.
    Zhao Z; Fischer R; Frerichs I; Müller-Lisse U; Möller K
    J Cyst Fibros; 2012 Sep; 11(5):412-8. PubMed ID: 22658424
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Regional lung function measures determined by electrical impedance tomography during repetitive ventilation manoeuvres in patients with COPD.
    Lasarow L; Vogt B; Zhao Z; Balke L; Weiler N; Frerichs I
    Physiol Meas; 2021 Feb; 42(1):015008. PubMed ID: 33434902
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Electrical impedance tomography in 3D using two electrode planes: characterization and evaluation.
    Wagenaar J; Adler A
    Physiol Meas; 2016 Jun; 37(6):922-37. PubMed ID: 27203154
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Electrical impedance tomography as possible guidance for individual positioning of patients with multiple lung injury.
    Lehmann S; Leonhardt S; Ngo C; Bergmann L; Schrading S; Heimann K; Wagner N; Tenbrock K
    Clin Respir J; 2018 Jan; 12(1):68-75. PubMed ID: 27058971
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.