BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

137 related articles for article (PubMed ID: 36087910)

  • 1. The Characteristic of Light Sources and Fluorescence in the 3-Dimensional Digital Exoscope "ORBEYE" for 5-Aminolevulinic Acid-Induced Fluorescence-Guided Surgery Compared with a Conventional Microscope.
    Ikeda N; Furuse M; Futamura G; Kimura S; Nonoguchi N; Kawabata S; Kameda M; Yokoyama K; Takami T; Kawanishi M; Kajimoto Y; Kuroiwa T; Wanibuchi M
    World Neurosurg; 2022 Nov; 167():e1268-e1274. PubMed ID: 36087910
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Neurosurgical microscopic solid laser-based light inhibits photobleaching during fluorescence-guided brain tumor removal with 5-aminolevulinic acid.
    Matsuda F; Ikeda N; Kajimoto Y; Nonoguchi N; Takeuchi K; Fukumura M; Kawabata S; Furuse M; Sugano T; Sato T; Saito K; Kuroiwa T
    Photodiagnosis Photodyn Ther; 2017 Dec; 20():120-124. PubMed ID: 28935534
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Optimization of novel exoscopic blue light filter during fluorescence-guided resection of Glioblastoma.
    Witten AJ; Ben-Shalom N; Ellis JA; Boockvar JA; D'Amico RS
    J Neurooncol; 2023 Feb; 161(3):617-623. PubMed ID: 36745272
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Red-light excitation of protoporphyrin IX fluorescence for subsurface tumor detection.
    Roberts DW; Olson JD; Evans LT; Kolste KK; Kanick SC; Fan X; Bravo JJ; Wilson BC; Leblond F; Marois M; Paulsen KD
    J Neurosurg; 2018 Jun; 128(6):1690-1697. PubMed ID: 28777025
    [TBL] [Abstract][Full Text] [Related]  

  • 5. A Comparative Analysis with Exoscope and Optical Microscope for Intraoperative Visualization and Surgical Workflow in 5-Aminolevulinic Acid-Guided Resection of High-Grade Gliomas.
    Della Pepa GM; Mattogno P; Menna G; Agostini L; Olivi A; Doglietto F
    World Neurosurg; 2023 Feb; 170():133-137. PubMed ID: 36400360
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Dual-labeling with 5-aminolevulinic acid and fluorescein for fluorescence-guided resection of high-grade gliomas: technical note.
    Suero Molina E; Wölfer J; Ewelt C; Ehrhardt A; Brokinkel B; Stummer W
    J Neurosurg; 2018 Feb; 128(2):399-405. PubMed ID: 28338432
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A Prospective Validation Study of the First 3D Digital Exoscope for Visualization of 5-ALA-Induced Fluorescence in High-Grade Gliomas.
    Vogelbaum MA; Kroll D; Etame A; Tran N; Liu J; Ford A; Sparr E; Kim Y; Forsyth P; Sahebjam S; Mokhtari S; Peguero E; Macaulay R
    World Neurosurg; 2021 May; 149():e498-e503. PubMed ID: 33561551
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Novel Wavelength-Specific Blue Light-Emitting Headlamp for 5-Aminolevulinic Acid Fluorescence-Guided Resection of Glioblastoma.
    Woo PYM; Law M; Gai X; Ng BCF; Ko NMW; Wong HT; Chan KY
    World Neurosurg; 2019 Nov; 131():220-226. PubMed ID: 31415891
    [TBL] [Abstract][Full Text] [Related]  

  • 9. 5-ALA fluorescence-guided resection of pediatric low-grade glioma using the ORBEYE 3D digital exoscope: a technical report.
    Maeda M; Nonaka M; Naito N; Ueno K; Kamei T; Asai A
    Childs Nerv Syst; 2023 Apr; 39(4):1061-1064. PubMed ID: 35907005
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Validating a new generation filter system for visualizing 5-ALA-induced PpIX fluorescence in malignant glioma surgery: a proof of principle study.
    Suero Molina E; Stögbauer L; Jeibmann A; Warneke N; Stummer W
    Acta Neurochir (Wien); 2020 Apr; 162(4):785-793. PubMed ID: 32034493
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Quantitative fluorescence using 5-aminolevulinic acid-induced protoporphyrin IX biomarker as a surgical adjunct in low-grade glioma surgery.
    Valdés PA; Jacobs V; Harris BT; Wilson BC; Leblond F; Paulsen KD; Roberts DW
    J Neurosurg; 2015 Sep; 123(3):771-80. PubMed ID: 26140489
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Endoscopic identification and biopsy sampling of an intraventricular malignant glioma using a 5-aminolevulinic acid-induced protoporphyrin IX fluorescence imaging system. Technical note.
    Tamura Y; Kuroiwa T; Kajimoto Y; Miki Y; Miyatake S; Tsuji M
    J Neurosurg; 2007 Mar; 106(3):507-10. PubMed ID: 17367078
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Spectral Radiance of Protoporphyrin IX Fluorescence and Its Histopathological Implications in 5-Aminolevulinic Acid-Guided Surgery for Glioblastoma.
    Yoneda T; Nonoguchi N; Ikeda N; Yagi R; Kawabata S; Furuse M; Hirose Y; Kuwabara H; Tamura Y; Kajimoto Y; Kuroiwa T
    Photomed Laser Surg; 2018 May; 36(5):266-272. PubMed ID: 29480754
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Improving the Usability of 5-Aminolevulinic Acid Fluorescence-Guided Surgery by Adding an Optimized Secondary Light Source.
    Elliott JT; Wirth DJ; Davis SC; Olson JD; Simmons NE; Ryken TC; Paulsen KD; Roberts DW
    World Neurosurg; 2021 May; 149():195-203.e4. PubMed ID: 33588080
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Optical Characterization of Neurosurgical Operating Microscopes: Quantitative Fluorescence and Assessment of PpIX Photobleaching.
    Belykh E; Miller EJ; Patel AA; Bozkurt B; Yağmurlu K; Robinson TR; Nakaji P; Spetzler RF; Lawton MT; Nelson LY; Seibel EJ; Preul MC
    Sci Rep; 2018 Aug; 8(1):12543. PubMed ID: 30135440
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Technical principles for protoporphyrin-IX-fluorescence guided microsurgical resection of malignant glioma tissue.
    Stummer W; Stepp H; Möller G; Ehrhardt A; Leonhard M; Reulen HJ
    Acta Neurochir (Wien); 1998; 140(10):995-1000. PubMed ID: 9856241
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Intraoperative detection of malignant gliomas by 5-aminolevulinic acid-induced porphyrin fluorescence.
    Stummer W; Stocker S; Wagner S; Stepp H; Fritsch C; Goetz C; Goetz AE; Kiefmann R; Reulen HJ
    Neurosurgery; 1998 Mar; 42(3):518-25; discussion 525-6. PubMed ID: 9526986
    [TBL] [Abstract][Full Text] [Related]  

  • 18. 5-Aminolevulinic Acid-Shedding Light on Where to Focus.
    Dadario NB; Khatri D; Reichman N; Nwagwu CD; D'Amico RS
    World Neurosurg; 2021 Jun; 150():9-16. PubMed ID: 33684574
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Is the Intensity of 5-Aminolevulinic Acid-Derived Fluorescence Related to the Light Source?
    Kamp MA; Knipps J; Neumann LM; Mijderwijk HJ; Dibué-Adjei M; Steiger HJ; Slotty PJ; Rapp M; Cornelius JF; Sabel M
    World Neurosurg; 2019 Nov; 131():e271-e276. PubMed ID: 31351208
    [TBL] [Abstract][Full Text] [Related]  

  • 20. The Evolution of 5-Aminolevulinic Acid Fluorescence Visualization: Time for a Headlamp/Loupe Combination.
    Giantini-Larsen AM; Parker WE; Cho SS; Goldberg JL; Carnevale JA; Michael AP; Teng CW; De Ravin E; Brennan CW; Lee JYK; Schwartz TH
    World Neurosurg; 2022 Mar; 159():136-143. PubMed ID: 34971836
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.